Optimization of a Packed Bed Thermal Energy Storage Unit

1987 ◽  
Vol 109 (3) ◽  
pp. 170-175 ◽  
Author(s):  
H. Torab ◽  
D. E. Beasley

The optimization of the design of a packed-bed thermal energy storage unit is presented. A one-dimensional, transient, two-phase model is chosen for the packed bed which assumes uniformity at each cross section within the packing. The governing equations for the time dependent temperature distributions in both the solid and fluid phases are solved using a fully implicit formulation. The accuracy of the numerical method is demonstrated by comparison with experimental measurements of temperature distribution in a randomly packed bed of uniform spheres. The goal of the optimization is to achieve maximum utilization of the thermal energy storage and recovery capabilities of the storage medium for a given set of operating conditions. The optimum combination of bed length, size of the packing particles, and relative size of the bed cross section to the particle diameter is determined, subject to constraints on the maximum allowable pressure drop across the packing, the maximum outlet fluid temperature, and the total amount of supplied energy. The thermodynamic availability is examined as the measure of storage utilization. The monotinicity method is utilized for the optimization process. This method identifies a global optimum without any special computations, and prevents acceptance of false optimum solutions, as could be generated by numerical techniques. The results of the study provide guidelines for choosing the size of the packing and the packing particle subject to the constraints for a practical operating system.

2013 ◽  
Vol 773 ◽  
pp. 143-147
Author(s):  
Yu Ju Zhao ◽  
Ji Hong Pei ◽  
Hai Ting Cui

A thermal energy storage unit laboratory with solar heat sources being designed and constructed. The spherical capsules which filled in phase change material (PCM) were put into the unit. Many groups' experiment schemes was designed and the discharging experiment is done, different import temperature and flow rate of HTF were experimented repeatedly, the effects of inlet fluid temperature and flow rate of HTF on the performance of the storage unit was analyzed. The experimental result shows that, with the import temperature and flow rate of HTF increased, the time finishes discharging reducing constantly, the efficiency of thermal energy storage is improved. The results offer the reference basis for design, optimization, and appreciation of the TES unit.The test data was compared with simulation data,the simulated results and experimental results agree well with the experimental results.


Sign in / Sign up

Export Citation Format

Share Document