Temperature Control of Line-Focus Solar Collectors

1983 ◽  
Vol 105 (2) ◽  
pp. 194-199
Author(s):  
J. D. Wright ◽  
M. Masterson

Solar thermal electric power and industrial process heat systems may require a constant outlet temperature from the collector. This temperature may be efficiently maintained by adjusting the circulating fluid flow rate. Using frequency response techniques, simple relations are developed which relate controller tuning constants to collector construction and field layout. Successful controller tuning is shown to be a compromise between good response at high flow rates and stability at low flow rates. The rules of thumb are then tested by performing dynamic numerical simulations of a collector row with flow rate control.

2018 ◽  
Vol 2018 ◽  
pp. 1-4
Author(s):  
Vorasruang Thongsukh ◽  
Chanida Kositratana ◽  
Aree Jandonpai

Introduction. In patients who require a massive intraoperative transfusion, cold fluid or blood transfusion can cause hypothermia and potential adverse effects. One method by which to prevent hypothermia in these patients is to warm the intravenous fluid before infusion. The aim of this study was to determine the effect of the fluid flow rate on the efficacy of a fluid warmer. Methods. The room air temperature was controlled at 24°C. Normal saline at room temperature was used for the experiment. The fluid was connected to an infusion pump and covered with a heater line, which constantly maintained the temperature at 42°C. The fluid temperature after warming was measured by an insulated thermistor at different fluid flow rates (100, 300, 600, 900, and 1200 mL/h) and compared with the fluid temperature before warming. Effective warming was defined as an outlet fluid temperature of >32°C. Results. The room temperature was 23.6°C ± 0.9°C. The fluid temperature before warming was 24.95°C ± 0.5°C. The outlet temperature was significantly higher after warming at all flow rates (p<0.001). The increases in temperature were 10.9°C ± 0.1°C, 11.5°C ± 0.1°C, 10.2°C ± 0.1°C, 10.1°C ± 0.7°C, and 8.4°C ± 0.2°C at flow rates of 100, 300, 600, 900, and 1200 mL/h, respectively. The changes in temperature among all different flow rates were statistically significant (p<0.001). The outlet temperature was >32°C at all flow rates. Conclusions. The efficacy of fluid warming was inversely associated with the increase in flow rate. The outlet temperature was <42°C at fluid flow rates of 100 to 1200 mL/h. However, all outlet temperatures reached >32°C, indicating effective maintenance of the core body temperature by infusion of warm fluid.


1981 ◽  
Vol 103 (3) ◽  
pp. 244-250 ◽  
Author(s):  
J. D. Wright

Solar thermal electric power and industrial process heat systems may require a constant outlet temperature from the collector field. This constant temperature is most efficiently maintained by adjusting the circulating fluid flow rate. Successful tuning of analog or digital controllers requires a knowledge of system dynamics. Models relating deviations in outlet temperature to changes in inlet temperature, insolation, and fluid flow rate illustrate the basic responses and the distributed-parameter nature of line-focus collectors. When plotted in dimensionless form, the frequency response of a given collector is essentially independent of the operating conditions, suggesting that feedback controller settings are directly related to such easily determined quantities as collector gain and fluid residence time.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Marie L. Salva ◽  
Yuksel Temiz ◽  
Marco Rocca ◽  
Yulieth C. Arango ◽  
Christof M. Niemeyer ◽  
...  

AbstractFlow rates play an important role in microfluidic devices because they affect the transport of chemicals and determine where and when (bio)chemical reactions occur in these devices. Flow rates can conveniently be determined using external peripherals in active microfluidics. However, setting specific flow rates in passive microfluidics is a significant challenge because they are encoded on a design and fabrication level, leaving little freedom to users for adjusting flow rates for specific applications. Here, we present a programmable hydraulic resistor where an array of “electrogates” routes an incoming liquid through a set of resistors to modulate flow rates in microfluidic chips post-fabrication. This approach combines a battery-powered peripheral device with passive capillary-driven microfluidic chips for advanced flow rate control and measurement. We specifically show a programmable hydraulic resistor composed of 7 parallel resistors and 14 electrogates. A peripheral and smartphone application allow a user to activate selected electrogates and resistors, providing 127 (27-1) flow resistance combinations with values spanning on a 500 fold range. The electrogates feature a capillary pinning site (i.e. trench across the flow path) to stop a solution and an electrode, which can be activated in a few ms using a 3 V bias to resume flow based on electrowetting. The hydraulic resistor and microfluidic chip shown here enable flow rates from ~0.09 nL.s−1 up to ~5.66 nL.s−1 with the resistor occupying a footprint of only 15.8 mm2 on a 1 × 2 cm2 microfluidic chip fabricated in silicon. We illustrate how a programmable hydraulic resistor can be used to set flow rate conditions for laminar co-flow of 2 liquids and the enzymatic conversion of a substrate by stationary enzymes (alkaline phosphatase) downstream of the programmable hydraulic resistor.


ORL ◽  
2021 ◽  
pp. 1-5
Author(s):  
Jingjing Liu ◽  
Tengfang Chen ◽  
Zhenggang Lv ◽  
Dezhong Wu

<b><i>Introduction:</i></b> In China, nasal cannula oxygen therapy is typically humidified. However, it is difficult to decide whether to suspend nasal cannula oxygen inhalation after the nosebleed has temporarily stopped. Therefore, we conducted a preliminary investigation on whether the use of humidified nasal cannulas in our hospital increases the incidence of epistaxis. <b><i>Methods:</i></b> We conducted a survey of 176,058 inpatients in our hospital and other city branches of our hospital over the past 3 years and obtained information concerning their use of humidified nasal cannulas for oxygen inhalation, nonhumidified nasal cannulas, anticoagulant and antiplatelet drugs, and oxygen inhalation flow rates. This information was compared with the data collected at consultation for epistaxis during these 3 years. <b><i>Results:</i></b> No significant difference was found between inpatients with humidified nasal cannulas and those without nasal cannula oxygen therapy in the incidence of consultations due to epistaxis (χ<sup>2</sup> = 1.007, <i>p</i> &#x3e; 0.05). The same trend was observed among hospitalized patients using anticoagulant and antiplatelet drugs (χ<sup>2</sup> = 2.082, <i>p</i> &#x3e; 0.05). Among the patients with an inhaled oxygen flow rate ≥5 L/min, the incidence of ear-nose-throat (ENT) consultations due to epistaxis was 0. No statistically significant difference was found between inpatients with a humidified oxygen inhalation flow rate &#x3c;5 L/min and those without nasal cannula oxygen therapy in the incidence of ENT consultations due to epistaxis (χ<sup>2</sup> = 0.838, <i>p</i> &#x3e; 0.05). A statistically significant difference was observed in the incidence of ENT consultations due to epistaxis between the low-flow nonhumidified nasal cannula and nonnasal cannula oxygen inhalation groups (χ<sup>2</sup> = 18.428, <i>p</i> &#x3c; 0.001). The same trend was observed between the 2 groups of low-flow humidified and low-flow nonhumidified nasal cannula oxygen inhalation (χ<sup>2</sup> = 26.194, <i>p</i> &#x3c; 0.001). <b><i>Discussion/Conclusion:</i></b> Neither high-flow humidified nasal cannula oxygen inhalation nor low-flow humidified nasal cannula oxygen inhalation will increase the incidence of recurrent or serious epistaxis complications; the same trend was observed for patients who use anticoagulant and antiplatelet drugs. Humidification during low-flow nasal cannula oxygen inhalation can prevent severe and repeated epistaxis to a certain extent.


2006 ◽  
Vol 1127 (1-2) ◽  
pp. 214-220 ◽  
Author(s):  
Yuushi Sai ◽  
Masumi Yamada ◽  
Masahiro Yasuda ◽  
Minoru Seki

Author(s):  
Lie Tang ◽  
Jianzhong Ruan ◽  
Robert G. Landers ◽  
Frank Liou

This paper proposes a novel method, called Variable Powder Flow Rate Control (VPFRC), for the regulation of powder flow rate in laser metal deposition processes. The idea of VPFRC is to adjust the powder flow rate to maintain a uniform powder deposition per unit length even when disturbances occur (e.g., the motion system accelerates and decelerates). Dynamic models of the powder delivery system motor and the powder transport system (i.e., five–meter pipe, powder dispenser, and cladding head) are constructed. A general tracking controller is then designed to track variable powder flow rate references. Since the powder flow rate at the nozzle exit cannot be directly measured, it is estimated using the powder transport system model. The input to this model is the DC motor rotation speed, which is estimated on–line using a Kalman filter. Experiments are conducted to examine the performance of the proposed control methodology. The experimental results demonstrate that the VPFRC method is successful in maintaining a uniform track morphology, even when the motion system accelerates and decelerates.


Author(s):  
Shuai Wu ◽  
Richard Burton ◽  
Zongxia Jiao ◽  
Juntao Yu ◽  
Rongjie Kang

This paper considers the feasibility of a new type of voice coil motor direct drive flow control servo valve. The proposed servo valve controls the flow rate using only a direct measurement of the spool position. A neural network is used to estimate the flow rate based on the spool position, velocity and coil current. The estimated flow rate is fed back to a closed loop controller. The feasibility of the concept is established using simulation techniques only at this point. All results are validated by computer co-simulation using AMESim and Simulink. A simulated model of a VCM-DDV (Voice Coil Motor-Direct Drive Valve) and hydraulic test circuit are built in an AMESim environment. A virtual digital controller is developed in a Simulink environment in which the feedback signals are received from the AMESim model; the controller outputs are sent to the VCM-DDV model in AMESim (by interfacing between these two simulation packages). A LQR (Linear Quadratic Regulator) state feedback and nonlinear compensator controller for spool position tracking is considered as this is the first step for flow control. A flow rate control loop is subsequently included via a neural network flow rate estimator. Simulation results show that this method could control the flow rate to an acceptable degree of precision, but only at low frequencies. This kind of valve can find usage in open loop hydraulic velocity control in many industrial applications.


Sign in / Sign up

Export Citation Format

Share Document