Gradient Zone Constraints in a Salt-Stratified Solar Pond

1982 ◽  
Vol 104 (4) ◽  
pp. 280-285 ◽  
Author(s):  
T. A. Newell ◽  
R. F. Boehm

An operational condition is defined for a salt-stratified solar pond. A criterion based on empirical evidence is formulated which shows a limit is approached as steady operating conditions are attained. For sodium chloride ponds, the criterion indicates a dependence between salt and temperature gradients during steady-state conditions. At the present time, appropriate data for explaining the physical basis of this relationship are not available. Significant results are found as a result of the gradient zone criterion. First, the gradient zone criterion leads to an explanation for the formation of an upper convecting zone. Results obtained with the gradient zone criterion relate to salt maintenance in a pond. Depending on the temperature operating conditions of a pond, a specific amount of salt must be in the pond. Also, salt concentration levels maintained in the upper and lower convecting zones are shown to significantly affect a pond’s thermal energy performance.

1995 ◽  
Vol 117 (2) ◽  
pp. 144-150 ◽  
Author(s):  
J. Estevadeordal ◽  
S. J. Kleis

The erosion the dynamically stable gradient zone of a salinity-gradient solar pond, due to the extraction of fluid from the storage zone, is numerically investigated. The effects of fluid withdrawal rate, density stratification level, pond and diffuser geometries, and diffuser placement are considered. It is found, for a typical salinity-gradient solar pond with uniform salinity in the storage zone and a continuous salinity gradient above that a finite amount of fluid entrainment from the gradient zone is inevitable. That is, a finite density difference across the interface is always required for a finite extraction rate under steady-state conditions. The magnitude of the density difference is predicted as function of the geometric and flow parameters. From the results, it is possible to predict the total amount of fluid entrained from the gradient zone as the pond reaches steady-state for prescribed operating conditions.


1992 ◽  
Vol 26 (5-6) ◽  
pp. 1355-1363 ◽  
Author(s):  
C-W. Kim ◽  
H. Spanjers ◽  
A. Klapwijk

An on-line respiration meter is presented to monitor three types of respiration rates of activated sludge and to calculate effluent and influent short term biochemical oxygen demand (BODst) in the continuous activated sludge process. This work is to verify if the calculated BODst is reliable and the assumptions made in the course of developing the proposed procedure were acceptable. A mathematical model and a dynamic simulation program are written for an activated sludge model plant along with the respiration meter based on mass balances of BODst and DO. The simulation results show that the three types of respiration rate reach steady state within 15 minutes under reasonable operating conditions. As long as the respiration rate reaches steady state the proposed procedure calculates the respiration rate that is equal to the simulated. Under constant and dynamic BODst loading, the proposed procedure is capable of calculating the effluent and influent BODst with reasonable accuracy.


Author(s):  
Bassam A. Hemade ◽  
Hamed A. Ibrahim ◽  
Hossam E.A. Talaat

Background: The security assessment plays a crucial role in the operation of the modern interconnected power system network. Methods: Hence, this paper addresses the application of k-means clustering algorithm equipped with Principal Component Analysis (PCA) and silhouette analysis for the classification of system security states. The proposed technique works on three principal axes; the first stage involves contingency quantification based on developed insecurity indices, the second stage includes dataset preparation to enhance the overall performance of the proposed method using PCA and silhouette analysis, and finally the application of the clustering algorithm over data. Results: The proposed composite insecurity index uses available synchronized measurements from Phasor Measurement Units (PMUs) to assess the development of cascading outages. Considering different operational scenarios and multiple levels of contingencies (up to N-3), Fast Decoupled Power Flow (FDPF) have been used for contingency replications. The developed technique applied to IEEE 14-bus and 57-bus standard test system for steady-state security evaluation. Conclusion: The obtained results ensure the robustness and effectiveness of the established procedure in the assessment of the system security irrespective of the network size or operating conditions.


1986 ◽  
Vol 51 (11) ◽  
pp. 2481-2488
Author(s):  
Benitto Mayrhofer ◽  
Jana Mayrhoferová ◽  
Lubomír Neužil ◽  
Jaroslav Nývlt

The paper presents a simple model of recrystallization with countercurrent flows of the solution and the crystals being purified. The model assumes steady-state operating conditions, an equilibrium between the outlet streams of each stage, and the same equilibrium temperature and distribution coefficient for all stages. With these assumptions, the model provides the basis for analyzing the variation in the degree of purity as a function of the number of recrystallization stages. The analysis is facilitated by the use of a diagram constructed for the limiting case of perfect removal of the mother liquor from the crystals between the stages.


Author(s):  
Nishesh Jain ◽  
Esfand Burman ◽  
Dejan Mumovic ◽  
Mike Davies

To manage the concerns regarding the energy performance gap in buildings, a structured and longitudinal performance assessment of buildings, covering design through to operation, is necessary. Modelling can form an integral part of this process by ensuring that a good practice design stage modelling is followed by an ongoing evaluation of operational stage performance using a robust calibration protocol. In this paper, we demonstrate, via a case study of an office building, how a good practice design stage model can be fine-tuned for operational stage using a new framework that helps validate the causes for deviations of actual performance from design intents. This paper maps the modelling based process of tracking building performance from design to operation, identifying the various types of performance gaps. Further, during the operational stage, the framework provides a systematic way to separate the effect of (i) operating conditions that are driven by the building’s actual function and occupancy as compared with the design assumptions, and (ii) the effect of potential technical issues that cause underperformance. As the identification of issues is based on energy modelling, the process requires use of advanced and well-documented simulation tools. The paper concludes with providing an outline of the software platform requirements needed to generate robust design models and their calibration for operational performance assessments. Practical application The paper’s findings are a useful guide for building industry professionals to manage the performance gap with appropriate accuracy through a robust methodology in an easy to use workflow. The methodological framework to analyse building energy performance in-use links best practice design stage modelling guidance with a robust operational stage investigation. It helps designers, contractors, building managers and other stakeholders with an understanding of procedures to follow to undertake an effective measurement and verification exercise.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1200
Author(s):  
Yong-Joon Jun ◽  
Seung-ho Ahn ◽  
Kyung-Soon Park

The Green Remodeling Project under South Korea’s Green New Deal policy is a government-led project intended to strengthen the performance sector directly correlated with energy performance among various elements of improvement applicable to building remodeling by replacing insulation materials, introducing new and renewable energy, introducing high-efficiency equipment, etc., with public buildings taking the lead in green remodeling in order to induce energy efficiency enhancement in private buildings. However, there is an ongoing policy that involves the application of a fragmentary value judgment criterion, i.e., whether to apply technical elements confined to the enhancement of the energy performance of target buildings and the prediction of improvement effects according thereto, thus resulting in the phenomenon of another important value criterion for green remodeling, i.e., the enhancement of the occupant (user) comfort performance of target buildings as one of its purposes, being neglected instead. In order to accurately grasp the current status of these problems and to promote ‘expansion of the value judgment criteria for green remodeling’ as an alternative, this study collected energy usage data of buildings actually used by public institutions and then conducted a total analysis. After that, the characteristics of energy usage were analyzed for each of the groups of buildings classified by year of completion, thereby carrying out an analysis of the correlation between the non-architectural elements affecting the actual energy usage and the actual energy usage data. The correlation between the improvement performance of each technical element and the actual improvement effect was also analyzed, thereby ascertaining the relationship between the direction of major policy strategies and the actual energy usage. As a result of the relationship analysis, it was confirmed that the actual energy usage is more affected by the operating conditions of the relevant building than the application of individual strategic elements such as the performance of the envelope insulation and the performance of the high-efficiency system. In addition, it was also confirmed that the usage of public buildings does not increase in proportion to their aging. The primary goal of reducing energy usage in target buildings can be achieved if public sector (government)-led green remodeling is pushed ahead with in accordance with biased value judgment criteria, just as in the case of a campaign to refrain from operating cooling facilities in aging public buildings. However, it was possible to grasp through the progress of this study that the remodeling may also result in the deterioration of environmental comfort and stability, such as the numerical value of the indoor thermal environment. The results of this study have the significance of providing basic data for pushing ahead with a green remodeling policy in which the value judgment criteria for aging existing public buildings are more expanded, and it is necessary to continue research in such a direction that the quantitative purpose of green remodeling, which is to reduce energy usage in aging public buildings, and its qualitative purpose, which is to enhance their environmental performance for occupants’ comfort, can be mutually balanced and secured at the same time.


Author(s):  
Robson L. Silva ◽  
Bruno V. Sant′Ana ◽  
José R. Patelli ◽  
Marcelo M. Vieira

This paper aims to identify performance improvements in cooker-top gas burners for changes in its original geometry, with aspect ratios (ARs) ranging from 0.25 to 0.56 and from 0.28 to 0.64. It operates on liquefied petroleum gas (LPG) and five thermal power (TP) levels. Considering the large number of cooker-top burners currently being used, even slight improvements in thermal performance resulting from a better design and recommended operating condition will lead to a significant reduction of energy consumption and costs. Appropriate instrumentation was used to carry out the measurements and methodology applied was based on regulations from INMETRO (CONPET program for energy conversion efficiency in cook top and kilns), ABNT (Brazilian Technical Standards Normative) and ANP—National Agency of Petroleum, Natural Gas (NG) and Biofuels. The results allow subsidizing recommendations to minimum energy performance standards (MEPS) for residential use, providing also higher energy conversion efficiency and/or lower fuel consumption. Main conclusions are: (i) Smaller aspect ratios result in the same heating capacity and higher efficiency; (ii) higher aspect ratios (original burners) are fuel consuming and inefficient; (iii) operating conditions set on intermediate are lower fuel consumption without significant differences in temperature increases; (iv) Reynolds number lower than 500 provides higher efficiencies.


Author(s):  
Ioannis Vlaskos ◽  
Ennio Codan ◽  
Nikolaos Alexandrakis ◽  
George Papalambrou ◽  
Marios Ioannou ◽  
...  

The paper describes the design process for a controlled pulse turbocharging system (CPT) on a 5 cylinder 4-stroke marine engine and highlights the potential for improved engine performance as well as reduced smoke emissions under steady state and transient operating conditions, as offered by the following technologies: • controlled pulse turbocharging, • high pressure air injection onto the compressor impeller as well as into the air receiver, and • an electronic engine control system, including a hydraulic powered electric actuator. Calibrated engine simulation computer models based on the results of tests performed on the engine in its baseline configuration were used to design the CPT components. Various engine tests with CPT under steady state and transient operating conditions show the engine optimization process and how the above-mentioned technologies benefit engine behavior in both generator and propeller law operation.


Sign in / Sign up

Export Citation Format

Share Document