The Influence of Turbine Clearance Gap Leakage on Passage Velocity and Heat Transfer Near Blade Tips: Part I—Sink Flow Effects on Blade Pressure Side

1989 ◽  
Vol 111 (3) ◽  
pp. 284-292 ◽  
Author(s):  
D. E. Metzger ◽  
K. Rued

A study has been conducted to investigate influences of tip leakage flow on heat transfer and flow development along the pressure side of a gas turbine blade. An analysis of the sink character of the flow situation indicates that high velocities and accelerations are generated very near the gap, and an apparatus was specifically designed to model the phenomena and to permit resolution of the expected localized near-gap heat transfer enhancement. In the experiments, leakage flow was drawn from an adjustable stream wise corner slot in a straight square test channel. A thin stainless steel ohmic-heated test surface adjacent to the slot simulated the airfoil surface. Supporting nonintrusive mean and fluctuating flowfield measurements were conducted with a laser-Doppler anemometer to aid interpretation of the heat transfer results and to provide a basis for comparison with future numerical predictions. The flowfield measurements confirm that near the gap the flow is highly accelerated, and indicate apparent relaminarization of the initially turbulent boundary layer. The heat transfer measurements show that leakage generates large increases in local heating near the gap. The presence of this undesirable enhancement helps to explain observed in-service material distress and failures of blades that appear to initiate at the pressure side tip.

1989 ◽  
Vol 111 (3) ◽  
pp. 293-300 ◽  
Author(s):  
K. Rued ◽  
D. E. Metzger

An experimental study has been designed and conducted to investigate turbine blade suction side heat transfer and flow near the tip clearance gap. Modeling of the phenomena was carried out in a water tunnel with injection through an adjustable streamwise corner slot in a square test channel. A thin stainless steel ohmic-heated test surface adjacent to the slot simulated the airfoil surface and permitted fine resolution of local heat transfer rates. Mean and fluctuating flow field measurements were conducted with a laser-Doppler anemometer to aid interpretation of the heat transfer results and to provide a basis for comparison with future numerical predictions. The results indicate that flow leakage from the turbine tip clearance gap into the suction side hot gas path results in more extensive and complex heat transfer effects than those measured for the blade pressure side in the companion Part I study. The character of the heat transfer andflow field deviations from closed gap conditions is strongly dependent on the particular combination of flow and geometry parameters present. The observed characteristics have been partitioned into categories of similar behavior, and the parameter combinations that define the boundaries between categories have been tentatively identified for the benefit of designers. The overall conclusions of this study and of the parallel study reported in Part I are that the effects of tip leakage flow on airfoil surface heat transfer near the blade tip can be very significant on both pressure and suction sides, and should be taken into account in blade cooling specification and design.


Author(s):  
Arun K. Saha ◽  
Sumanta Acharya ◽  
Chander Prakash ◽  
Ron Bunker

A numerical study has been conducted to explore the effect of a pressure-side winglet on the flow and heat transfer over a blade tip. Calculations are performed for both a flat tip and a squealer tip. The winglet is in the form of a flat extension, and is shaped in the axial chord direction to have the maximum thickness at the chord location where the pressure difference is the largest between the pressure and suction sides. For the flat tip, the pressure side winglet exhibits a significant reduction in the leakage flow strength and an associated reduction in the aerodynamic loss. The low heat transfer coefficient “sweet-spot” region is larger with the pressure-side winglet, and lower heat transfer coefficients are also observed along the pressure side of the blade. The winglet reduces the average heat transfer coefficient by about 7%. In the presence of a squealer, the role of the winglet decreases significantly, and only a 0.5% reduction in the pressure ratio is achieved with the winglet with virtually no reduction in the average heat transfer coefficient.


Author(s):  
Toma´sˇ Hofer ◽  
Tony Arts

Modern high pressure turbines operate at high velocity and high temperature conditions. The gap existing above a turbine rotor blade is responsible for an undesirable tip leakage flow. It is a source of high aerodynamic losses and high heat transfer rates. A better understanding of the tip flow behaviour is needed to provide a more efficient cooling design in this region. The objective of this paper is to investigate the tip leakage flow for a blade with two different squealer tips and film-cooling applied on the pressure side and through tip dust holes in a non-rotating, linear cascade arrangement. The experiments were performed in the VKI Light Piston Compression Tube facility, CT-2. The tip gap flow was investigated by oil flow visualisations and by wall static and total pressure measurements. Two geometries were tested — a full squealer and a partial suction side squealer. The measurements were performed in the blade tip region, including the squealer rim and on the corresponding end-wall for engine representative values of outlet Reynolds and Mach numbers. The main flow structures in the cavity were put in evidence. Positive influence of the coolant on the tip gap flow and on the aerodynamic losses was found for the full squealer tip case: increasing the coolant mass-flow increased the tip gap flow resistance. The flow through the clearance therefore slows down, the tip gap mass-flow and the heat transfer respectively decreases. No such effect of cooling was found in the case of the partial suction side squealer geometry. The absence of a pressure side squealer rim resulted in a totally different tip gap flow topology, indifferent to cooling. The influence of cooling on the overall mass-weighted thermodynamic loss coefficient, which takes into account the different energies of the mainstream and coolant flows was found marginal for both geometries. Finally the overall loss coefficient was found to be higher for the partial suction side squealer tip than for the full squealer tip.


2012 ◽  
Vol 134 (6) ◽  
Author(s):  
Jin Wang ◽  
Bengt Sundén ◽  
Min Zeng ◽  
Qiu-wang Wang

Three-dimensional simulations of the squealer tip on the GE-E3 blade with eight film cooling holes were carried out. The effect of the rim width and the blowing ratio on the blade tip flow and cooling performance were revealed. Numerical simulations were performed to predict the leakage flow and the tip heat transfer with the k–ɛ model. For the squealer tip, the depth of the cavity is fixed but the rim width varies to form a wide cavity, which can decrease the coolant momentum and the tip leakage flow velocity. This cavity contributes to the improvement of the cooling effect in the tip zone. To investigate the influence on the tip heat transfer by the rim width, numerical simulations were performed as a two-part study: (1) unequal rim width study on the pressure side and the suction side and (2) equal rim width study with rim widths of 0.58%, 1.16%, and 1.74% of the axial chord (0.5 mm, 1 mm, and 1.5 mm, respectively) on both the pressure side rim and the suction side rim. With different rim widths, the effect of different global blowing ratios, i.e., M = 0.5, 1.0 and 1.5, was investigated. It is found that the total heat transfer rate is increasing and the heat transfer rates on the rim surface (RS) rapidly ascend with increasing rim width.


Author(s):  
Dianliang Yang ◽  
Xiaobing Yu ◽  
Zhenping Feng

In this paper, numerical methods have been applied to the investigation of the effect of rotation on the blade tip leakage flow and heat transfer. Using the first stage rotor blade of GE-E3 engine high pressure turbine, both flat tip and squealer tip have been studied. The tip gap height is 1% of the blade height, and the groove depth of the squealer tip is 2% of the blade height. Heat transfer coefficient on tip surface obtained by using different turbulence models was compared with experimental results. And the grid independence study was carried out by using the Richardson extrapolation method. The effect of the blade rotation was studied in the following cases: 1) blade domain is rotating and shroud is stationary; 2) blade domain is stationary and shroud is rotating; and 3) both blade domain and shroud are stationary. In this approach, the effects of the relative motion of the endwall, the centrifugal force and the Coriolis force can be investigated respectively. By comparing the results of the three cases discussed, the effects of the blade rotation on tip leakage flow and heat transfer are revealed. It indicated that the main effect of the rotation on the tip leakage flow and heat transfer is resulted from the relative motion of the shroud, especially for the squealer tip blade.


Author(s):  
Y. W. Kim ◽  
W. Abdel-Messeh ◽  
J. P. Downs ◽  
F. O. Soechting ◽  
G. D. Steuber ◽  
...  

The clearance gap between the stationary outer air seal and blade tips of an axial turbine allows a clearance gap leakage flow to be driven through the gap by the pressure-to-suction side pressure difference. The presence of strong secondary flows on the pressure side of the airfoil tends to deliver air from the hottest regions of the mainstream to the clearance gap. The blade tip region, particularly near the trailing edge, is very difficult to cool adequately with blade internal coolant flow. In this case, film cooling injection directly onto the blade tip region can be used in an attempt to directly reduce the heat transfer rates from the hot gases in the clearance gap to the blade tip. The present paper is intended as a memorial tribute to the late Professor Darryl E. Metzger who has made significant contributions in this particular area over the past decade. A summary of this work is made to present the results of his more recent experimental work that has been performed to investigate the effects of film coolant injection on convection heat transfer to the turbine blade tip for a variety of tip shapes and coolant injection configurations. Experiments are conducted with blade tip models that are stationary relative to the simulated outer air seal based on the result of earlier works that found the leakage flow to be mainly a pressure-driven flow which is related strongly to the airfoil pressure loading distribution and only weakly, if at all, to the relative motion between blade tip and shroud. Both heat transfer and film effectiveness are measured locally over the test surface using a transient thermal liquid crystal test technique with a computer vision data acquisition and reduction system for various combinations of clearance heights, clearance flow Reynolds numbers, and film flow rates with different coolant injection configurations. The present results reveal a strong dependency of film cooling performance on the choice of the coolant supply hole shapes and injection locations for a given tip geometry.


Author(s):  
Cengiz Camci ◽  
Debashis Dey ◽  
Levent Kavurmacioglu

This paper deals with an experimental investigation of aerodynamic characteristics of full and partial-length squealer rims in a turbine stage. Full and partial-length squealer rims are investigated separately on the pressure side and on the suction side in the “Axial Flow Turbine Research Facility” (AFTRF) of the Pennsylvania State University. The streamwise length of these “partial squealer tips” and their chordwise position are varied to find an optimal aerodynamic tip configuration. The optimal configuration in this cold turbine study is defined as the one that is minimizing the stage exit total pressure defect in the tip vortex dominated zone. A new “channel arrangement” diverting some of the leakage flow into the trailing edge zone is also studied. Current results indicate that the use of “partial squealer rims” in axial flow turbines can positively affect the local aerodynamic field by weakening the tip leakage vortex. Results also show that the suction side partial squealers are aerodynamically superior to the pressure side squealers and the channel arrangement. The suction side partial squealers are capable of reducing the stage exit total pressure defect associated with the tip leakage flow to a significant degree.


Author(s):  
Vikrant Saxena ◽  
Hasan Nasir ◽  
Srinath V. Ekkad

A comprehensive investigation of the effect of various tip sealing geometries is presented on the blade tip leakage flow and associated heat transfer of a scaled up HPT turbine blade in a low-speed wind tunnel facility. The linear cascade is made of four blades with the two corner blades acting as guides. The tip section of a HPT first stage rotor blade is used to fabricate the 2-D blade. The wind tunnel accommodates an 116° turn for the blade cascade. The mainstream Reynolds number based on the axial chord length at cascade exit is 4.83 × 105. The upstream wake effect is simulated with a spoked wheel wake generator placed upstream of the cascade. A turbulence grid placed even farther upstream generates the required free-stream turbulence of 4.8%. The center blade has a tip clearance gap of 1.5625% with respect to the blade span. Static pressure measurements are obtained on the blade surface and the shroud. The effect of crosswise trip strips to reduce leakage flow and associated heat transfer is investigated with strips placed along the leakage flow direction, against the leakage flow and along the chord. Cylindrical pin fins and pitch variation of strips over the tip surface are also investigated. Detailed heat transfer measurements are obtained using a steady state HSI-based liquid crystal technique. The effect of periodic unsteady wake effect is also investigated by varying the wake Strouhal number from 0. to 0.2, and to 0.4. Results show that the trip strips placed against the leakage flow produce the lowest heat transfer on the tips compared to all the other cases with a reduction between 10–15% compared to the plain tip. Results also show that the pitch of the strips has a small effect on the overall reduction. Cylindrical pins fins and strips along the leakage flow direction do not decrease the heat transfer coefficients and in some cases enhance the heat transfer coefficients by as much as 20%.


Author(s):  
S. K. Krishnababu ◽  
H. P. Hodson ◽  
G. D. Booth ◽  
G. D. Lock ◽  
W. N. Dawes

A numerical investigation of the flow and heat transfer characteristics of tip leakage in a typical film cooled industrial gas turbine rotor is presented in this paper. The computations were performed on a rotating domain of a single blade with a clearance gap of 1.28% chord in an engine environment. This standard blade featured two coolant and two dust holes, in a cavity-type tip with a central rib. The computations were performed using CFX 5.6, which was validated for similar flow situations by Krishnababu et al., [18]. These predictions were further verified by comparing the flow and heat transfer characteristics computed in the absence of coolant ejection with computations previously performed in the company (SIEMENS) using standard in-house codes. Turbulence was modelled using the SST k-ω turbulence model. The comparison of calculations performed with and without coolant ejection has shown that the coolant flow partially blocks the tip gap, resulting in a reduction of the amount of mainstream leakage flow. The calculations identified that the main detrimental heat transfer issues were caused by impingement of the hot leakage flow onto the tip. Hence three different modifications (referred as Cases 1 to 3) were made to the standard blade tip in an attempt to reduce the tip gap exit mass flow and the associated impingement heat transfer. The improvements and limitations of the modified geometries, in terms of tip gap exit mass flow, total area of the tip affected by the hot flow and the total heat flux to the tip, are discussed. The main feature of the Case 1 geometry is the removal of the rib and this modification was found to effectively reduce both the total area affected by the hot leakage flow and total heat flux to the tip while maintaining the same leakage mass flow as the standard blade. Case 2 featured a rearrangement of the dust holes in the tip which, in terms of aero-thermal-dynamics, proved to be marginally inferior to Case 1. Case 3, which essentially created a suction-side squealer geometry, was found to be inferior even to the standard cavity tip blade. It was also found that the hot spots which occur in the leading edge region of the standard tip and all modifications contributed significantly to the area affected by the hot tip leakage flow and the total heat flux.


Author(s):  
Qihe Huang ◽  
Jiao Wang ◽  
Lei He ◽  
Qiang Xu

A numerical study is performed to simulate the tip leakage flow and heat transfer on the first stage rotor blade tip of GE-E3 turbine, which represents a modern gas turbine blade geometry. Calculations consist of the flat blade tip without and with film cooling. For the flat tip without film cooling case, in order to investigate the effect of tip gap clearance on the leakage flow and heat transfer on the blade tip, three different tip gap clearances of 1.0%, 1.5% and 2.5% of the blade span are considered. And to assess the performance of the turbulence models in correctly predicting the blade tip heat transfer, the simulations have been performed by using four different models (the standard k-ε, the RNG k-ε, the standard k-ω and the SST models), and the comparison shows that the standard k-ω model provides the best results. All the calculations of the flat tip without film cooling have been compared and validated with the experimental data of Azad[1] and the predictions of Yang[2]. For the flat tip with film cooling case, three different blowing ratio (M = 0.5, 1.0, and 1.5) have been studied to the influence on the leakage flow in tip gap and the cooling effectiveness on the blade tip. Tip film cooling can largely reduce the overall heat transfer on the tip. And the blowing ratio M = 1.0, the cooling effect for the blade tip is the best.