Development of Convective Heat Transfer Near Suddenly Heated, Vertically Aligned Horizontal Wires

1987 ◽  
Vol 109 (4) ◽  
pp. 912-918 ◽  
Author(s):  
J. R. Parsons ◽  
M. L. Arey

Experiments have been performed which describe the transient development of natural convective flow from both a single and two vertically aligned horizontal cylindrical heat sources. The temperature of the wire heat sources was monitored with a resistance bridge arrangement while the development of the flow field was observed optically with a Mach–Zehnder interferometer. Results for the single wire show that after an initial regime where the wire temperature follows pure conductive response to a motionless fluid, two types of fluid motion will begin. The first is characterized as a local buoyancy, wherein the heated fluid adjacent to the wire begins to rise. The second is the onset of global convective motion, this being governed by the thermal stability of the fluid layer immediately above the cylinder. The interaction of these two motions is dependent on the heating rate and relative heat capacities of the cylinder and fluid, and governs whether the temperature response will exceed the steady value during the transient (overshoot). The two heat source experiments show that the merging of the two developing temperature fields is hydrodynamically stabilizing and thermally insulating. For small spacing-to-diameter ratios, the development of convective motion is delayed and the heat transfer coefficients degraded by the proximity of another heat source. For larger spacings, the transient behavior approaches that of a single isolated cylinder.

2013 ◽  
Vol 34 (1) ◽  
pp. 5-16 ◽  
Author(s):  
Jozef Cernecky ◽  
Jan Koniar ◽  
Zuzana Brodnianska

Abstract The paper deals with a study of the effect of regulating elements on local values of heat transfer coefficients along shaped heat exchange surfaces with forced air convection. The use of combined methods of heat transfer intensification, i.e. a combination of regulating elements with appropriately shaped heat exchange areas seems to be highly effective. The study focused on the analysis of local values of heat transfer coefficients in indicated cuts, in distances expressed as a ratio x/s for 0; 0.33; 0.66 and 1. As can be seen from our findings, in given conditions the regulating elements can increase the values of local heat transfer coefficients along shaped heat exchange surfaces. An optical method of holographic interferometry was used for the experimental research into temperature fields in the vicinity of heat exchange surfaces. The obtained values correspond very well with those of local heat transfer coefficients αx, recorded in a CFD simulation.


1987 ◽  
Vol 109 (3) ◽  
pp. 599-605 ◽  
Author(s):  
An-Shik Yang ◽  
Ching-Chang Chieng

An anisotropic factor is carefully selected from eleven distributions and adopted to the k–ε two-equation model of turbulence to obtain detailed velocity and temperature fields for steady-state, fully developed turbulent flow through infinite triangular/square rod array. The present study covers the ranges of pitch-to-diameter ratio from 1.123 to 1.5, and Reynolds number from 2.4 × 104 to 106. Velocity and wall shear stress are calculated and compared to experimental data. Normalized fluid temperature, friction factor, and heat transfer coefficient are also computed. The correlations of friction factor and heat transfer coefficients for flow inside circular pipe and flow through finite rod arrays are compared with the results for flow through infinite rod arrays.


Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1853 ◽  
Author(s):  
Pavel Neuberger ◽  
Radomír Adamovský

The efficiency of a heat pump energy system is significantly influenced by its low-temperature heat source. This paper presents the results of operational monitoring, analysis and comparison of heat transfer fluid temperatures, outputs and extracted energies at the most widely used low temperature heat sources within 218 days of a heating period. The monitoring involved horizontal ground heat exchangers (HGHEs) of linear and Slinky type, vertical ground heat exchangers (VGHEs) with single and double U-tube exchanger as well as the ambient air. The results of the verification indicated that it was not possible to specify clearly the most advantageous low-temperature heat source that meets the requirements of the efficiency of the heat pump operation. The highest average heat transfer fluid temperatures were achieved at linear HGHE (8.13 ± 4.50 °C) and double U-tube VGHE (8.13 ± 3.12 °C). The highest average specific heat output 59.97 ± 41.80 W/m2 and specific energy extracted from the ground mass 2723.40 ± 1785.58 kJ/m2·day were recorded at single U-tube VGHE. The lowest thermal resistance value of 0.07 K·m2/W, specifying the efficiency of the heat transfer process between the ground mass and the heat transfer fluid, was monitored at linear HGHE. The use of ambient air as a low-temperature heat pump source was considered to be the least advantageous in terms of its temperature parameters.


2005 ◽  
Vol 129 (2) ◽  
pp. 236-240 ◽  
Author(s):  
Jun Wen ◽  
M. M. Khonsari

An analytical technique is presented for treating heat conduction problems involving a body experiencing oscillating heat flux on its boundary. The boundary heat flux is treated as a combination of many point heat sources, each of which emits heat intermittently based on the motion of the flux. The working function of the intermittent heat source with respect to time is evaluated by using the Fourier series and temperature profile of each point heat source is derived by using the Duhamel’s theorem. Finally, by superposition of the temperature fields over all the point heat sources, the temperature profile due to the original moving heat flux is determined. Prediction results and verification using finite element method are presented for an oscillatory heat flux in a rectangular domain.


Mathematics ◽  
2022 ◽  
Vol 10 (2) ◽  
pp. 178
Author(s):  
Mohammed Alghaseb ◽  
Walid Hassen ◽  
Abdelhakim Mesloub ◽  
Lioua Kolsi

In this study, a 3D numerical study of free ventilated room equipped with a discrete heat source was performed using the Finite Volume Method (FVM). To ensure good ventilation, two parallel openings were created in the room. A suction opening was located at the bottom of the left wall and another opening was located at the top of the opposite wall; the heat source was placed at various positions in order to compare the heating efficiency. The effects of Rayleigh number (103 ≤ Ra ≤ 106) for six heater positions was studied. The results focus on the impact of these parameters on the particle trajectories, temperature fields and on the heat transfer inside the room. It was found that the position of the heater has a dramatic effect on the behavior and topography of the flow in the room. When the heat source was placed on the wall with the suction opening, two antagonistic behaviors were recorded: an improvement in heat transfer of about 31.6%, compared to the other positions, and a low Rayleigh number against 22% attenuation for high Ra values was noted.


Author(s):  
Rami Homsi ◽  
MD Islam ◽  
Yap Yit Fatt ◽  
Isam Janajreh

Abstract Heated and unheated flows with forced convection over two fixed circular cylinders in tandem are studied numerically for 80 ≤ Re ≤ 250 and 1 ≤ T* ≤ 2.3. Three different spacing ratios (L/D) = [2, 4, 8] are considered under three heating conditions. The scenarios considered are (1) heated upstream and unheated downstream cylinders, (2) unheated upstream and heated downstream cylinders and (3) heated upstream and downstream cylinders. These scenarios represent the limiting case for a cross-flow heat exchanger, where the downstream tubes are at increasingly lower or higher temperature for cooling or heating, respectively. The global aerodynamic forces on the cylinder as vortices shed was investigated. The flow is visualized by plotting the streamlines, temperature fields, and velocity magnitude contours for the different spacing ratios and compared to the flow regimes in literature namely, Extended-body, Reattachment, and Co-shedding regimes. The drag and surface heat transfer coefficients are analyzed for different scenarios. The effect of heating on the fluid properties and the resulted wakes in the flow are found to be strongly influenced by Re and L/D. The scenario of heated upstream and unheated downstream cylinders was found to increase the mean drag coefficient Cd on the upstream cylinder for L/D = 2 & 4 but is not as evident for the downstream cylinder. The heat transfer coefficient h on the upstream cylinder remained approximately the same regardless of a heated or unheated downstream cylinder. In contrast, h of the downstream cylinder decreases for the scenario of heated upstream and downstream cylinder.


1994 ◽  
Vol 116 (2) ◽  
pp. 465-472 ◽  
Author(s):  
A. Hadim

A numerical study is performed to analyze steady laminar forced convection in a channel filled with a fluid-saturated porous medium and containing discrete heat sources on the bottom wall. Hydrodynamic and heat transfer results are reported for two configurations: (1) a fully porous channel, and (2) a partially porous channel, which contains porous layers above the heat sources and is nonporous elsewhere. The flow in the porous medium is modeled using the Brinkman-Forchheimer extended Darcy model. Heat transfer rates and pressure drop are evaluated for wide ranges of Darcy and Reynolds numbers. Detailed results of the evolution of the hydrodynamic and thermal boundary layers are also provided. The results indicate that as the Darcy number decreases, a significant increase in heat transfer is obtained, especially at the leading edge of each heat source. For fixed Reynolds number, the length-averaged Nusselt number reaches an asymptotic value in the Darcian regime. In the partially porous channel, it is found that when the width of the heat source and the spacing between the porous layers are of the same magnitude as the channel height, the heat transfer enhancement is almost the same as in the fully porous channel while the pressure drop is significantly lower. These results suggest that the partially porous channel configuration is a potentially attractive heat transfer augmentation technique for electronic equipment cooling, an end that motivated this study.


1981 ◽  
Vol 103 (4) ◽  
pp. 720-726 ◽  
Author(s):  
A. G. Bathelt ◽  
R. Viskanta

The effectiveness of extended surfaces on a horizontal, cylindrical heat source/sink was studied experimentally during solid-liquid phase change heat transfer. Melting and freezing experiments were performed in a test cell suitable for photographic and shadowgraphic observations using a circular cylinder with three rectangular fins parallel to the axis and evenly distributed around the circumference of the heat exchanger. Results are reported for n-heptadecane as the phase change material. Orientation of fins on the heat exchanger with respect to the gravitational field are found to have more influence on the melting than on the freezing processes. The use of fins was found to be more effective for melting than for freezing. The instantaneous local and circumferentially averaged heat transfer coefficients at the heat source surface for melting from a cylinder with fins were usually within ±20 percent of those for melting from a bare cylinder. During solidification the degree of heat transfer enhancement due to finning is greatest when the frozen layer is thin and decreases as the layer grows thicker.


2008 ◽  
Vol 580-582 ◽  
pp. 279-282
Author(s):  
Zhi Ning Li ◽  
Bao Hua Chang ◽  
Dong Du ◽  
Hua Zhang

A three dimensional heat transfer model on laser-plasma hybrid welding has been proposed, that takes into account the interaction between laser beam and plasma arc. Through FEM computation, the temperature fields were computed and analyzed for an Al-Li alloy during laserplasma hybrid welding with different distances between the two heat sources. The simulation results are in agreement with the experimental results.


Sign in / Sign up

Export Citation Format

Share Document