Modeling of the Two-Phase Closed Thermosyphon

1987 ◽  
Vol 109 (3) ◽  
pp. 722-730 ◽  
Author(s):  
J. G. Reed ◽  
C. L. Tien

A comprehensive model is developed to predict the steady-state and transient performance of the two-phase closed thermosyphon. One-dimensional governing equations for the liquid and vapor phases are developed using available correlations to specify the shear stress and heat transfer coefficients. Steady-state solutions agree well with thermosyphon flooding data from several sources and with film thickness data obtained in the present investigation. While no data are available with which to compare the transient analysis, the results indicate that, for most systems, the governing time scale for system transients is the film residence time, which is typically much longer than the times required for viscous and thermal diffusion through the film. The proposed model offers a versatile and comprehensive analysis tool which is relatively simple.

Author(s):  
Koichi Araga ◽  
Keisuke Okamoto ◽  
Keiji Murata

This paper presents an experimental investigation of the forced convective boiling of refrigerant HCFC123 in a mini-tube. The inner diameters of the test tubes, D, were 0.51 mm and 0.30 mm. First, two-phase frictional pressure drops were measured under adiabatic conditions and compared with the correlations for conventional tubes. The frictional pressure drop data were lower than the correlation for conventional tubes. However, the data were qualitatively in accord with those for conventional tubes and were correlated in the form φL2−1/Xtt. Next, heat transfer coefficients were measured under the conditions of constant heat flux and compared with those for conventional tubes and for pool boiling. The heat transfer characteristics for mini-tubes were different from those for conventional tubes and quite complicated. The heat transfer coefficients for D = 0.51 mm increased with heat flux but were almost independent of mass flux. Although the heat transfer coefficients were higher than those for a conventional tube with D = 10.3 mm and for pool boiling in the low quality region, they decreased gradually with increasing quality. The heat transfer coefficients for D = 0.30 mm were higher than those for D = 0.51 mm and were almost independent of both mass flux and heat flux.


Author(s):  
Bao H. Truong

Nanofluids are engineered colloids composed of nano-size particles dispersed in common fluids such as water or refrigerants. Using an electrically controlled wire heater, pool boiling Critical Heat Flux (CHF) of Alumina and Silica water-based nanofluids of concentration less than or equal to 0.1 percent by volume were measured. Silica nanofluids showed a CHF enhancement up to 68% and there seems to be a monotonic relationship between the nanoparticle concentration and the magnitude of enhancement. Alumina nanofluids had a CHF enhancement up to 56% but the peak occurred at the intermediate concentration. The boiling curves in nanofluid were found to shift to the left of that of water and correspond to higher nucleate boiling heat transfer coefficients in the two-phase flow regime. Scanning Electron Microscopy (SEM) images show a porous coating layer of nanoparticles on wires subjected to nanofluid CHF tests. These coating layers change the morphology of the heater’s surface, and are responsible for the CHF enhancement. The thickness of the coating was estimated using SEM and was found ranging from 3.0 to 6.0 micrometers for Alumina, and 3.0 to 15.0 micrometers for Silica.


Author(s):  
Wenhai Li ◽  
Ken Alabi ◽  
Foluso Ladeinde

Over the years, empirical correlations have been developed for predicting saturated flow boiling [1–15] and condensation [16–30] heat transfer coefficients inside horizontal/vertical tubes or micro-channels. In the present work, we have examined 30 of these models, and modified many of them for use in compact plate-fin heat exchangers. However, the various correlations, which have been developed for pipes and ducts, have been modified in our work to make them applicable to extended fin surfaces. The various correlations have been used in a low-order, one-dimensional, finite-volume type numerical integration of the flow and heat transfer equations in heat exchangers. The NIST’s REFPROP database [31] is used to account for the large variations in the fluid thermo-physical properties during phase change. The numerical results are compared with Yara’s experimental data [32]. The validity of the various boiling and condensation models for a real plate-fin heat exchanger design is discussed. The results show that some of the modified boiling and condensation correlations can provide acceptable prediction of heat transfer coefficient for two-phase flows in compact plate-fin heat exchangers.


2020 ◽  
Vol 142 (3) ◽  
Author(s):  
Ruiyang Wang ◽  
Bingen Yang

Abstract In Part I of this two-part paper, a new benchmark transient model of Inductrack systems is developed. In this Part II, the proposed model, which is governed by a set of non-linear integro-differential governing equations, is used to predict the dynamic response of Inductrack systems. In the development, a state-space representation of the non-linear governing equations is established and a numerical procedure with a specific moving circuit window for transient solutions is designed. The dynamic analysis of Inductrack systems with the proposed model has two major tasks. First, the proposed model is validated through comparison with the noted steady-state results in the literature. Second, the transient response of an Inductrack system is simulated and analyzed in several typical dynamic scenarios. The steady-state response results predicted by the new model agree with those obtained in the previous studies. On the other hand, the transient response simulation results reveal that an ideal steady-state response can hardly exist in those investigated dynamic scenarios. It is believed that the newly developed transient model provides a useful tool for dynamic analysis of Inductrack systems and for in-depth understanding of the complicated electro-magneto-mechanical interactions in this type of dynamic systems.


Author(s):  
Cheol Huh ◽  
Moo Hwan Kim

With a single microchannel and a series of microheaters made with MEMS technique, two-phase pressure drop and local flow boiling heat transfer were investigated using deionized water in a single horizontal rectangular microchannel. The test microchannel has a hydraulic diameter of 100 μm and length of 40 mm. A real time observation of the flow patterns with simultaneous measurement are made possible. Tests are performed for mass fluxes of 90, 169, and 267 kg/m2s and heat fluxes of from 100 to 600 kW/m2. The experimental local flow boiling heat transfer coefficients and two-phase frictional pressure gradient are evaluated and the effects of heat flux, mass flux, and vapor qualities on flow boiling are studied. Both the evaluated experimental data are compared with existing correlations. The experimental heat transfer coefficients are nearly independent on mass flux and the vapor quality. Most of all correlations do not provide reliable heat transfer coefficients predictions with vapor quality and prediction accuracy. As for two-phase pressure drop, the measured pressure drop increases with the mass flux and heat flux. Most of all existing correlations of two-phase frictional pressure gradient do not predict the experimental data except some limited conditions.


Author(s):  
Jason Chan ◽  
Brian E. Fehring ◽  
Roman W. Morse ◽  
Kristofer M. Dressler ◽  
Gregory F. Nellis ◽  
...  

Abstract A thermoreflectance method to measure wall temperature in two-phase annular flow is described. In high heat flux conditions, momentary dry-out occurs as the liquid film vaporizes, resulting in dramatic decreases in heat transfer coefficient. Simultaneous liquid and vapor thermoreflectance measurements allow calculations of instantaneous and time-averaged heat transfer coefficients. Validation, calibration and uncertainty of the technique are discussed.


Author(s):  
Haruhiko Ohta ◽  
Koichi Inoue ◽  
Yuichiro Shimada

Flow boiling heat transfer in a single small tube is investigated by using FC72 as a working fluid. The heat transfer coefficients are measured in the ranges of heat flux 2–24kW/m2 and mass velocity 100–400kg/m2s under the condition of near atmospheric pressure. Test tube, made of stainless steel, has an inner diameter of 0.51mm and a heated length of 200mm. The tube is located horizontally in a vacuum chamber to reduce the heat loss and to minimize the time to obtain data regarded as that of steady state. In the single-phase region, heat transfer coefficients due to forced convection are in good agreement with the values from the conventional theories. In the saturated region, measured heat transfer characteristics are quite different depending on whether the test liquid is deaerated or not deaerated before the experiments. By using deaerated liquid, three different heat transfer regimes are observed: In the first regime, the heat transfer is dominated by nucleate boiling in low vapor quality, and the heat transfer is deteriorated or enhanced depending on the channel confinement and heat flux. In the second regime, the heat transfer is dominated by two-phase forced convection in moderate quality as is well known for the tubes of normal size. In the third regime, the heat transfer is dominated again by two-phase forced convection, but is deteriorated in high quality. One or two regimes can disappear or become unclear depending on the conditions of flow and heating. The effects of vapor quality and mass velocity on the heat transfer characteristics due to two-phase forced convection in the moderate vapor quality are clarified in the experimental ranges tested. And a reason for the gradual heat transfer deterioration observed in high quality is discussed based on the liquid-vapor behaviors inherent in small diameter tubes.


Author(s):  
Seungwhan Baek ◽  
Sangkwon Jeong

Mixed Refrigerant Joule Thomson (MR-JT) refrigerators are widely used in various kinds of cryogenic systems these days. Although heat transfer coefficient estimation for a multiphase and multi-component fluid in cryogenic temperature range is necessarily required in the heat exchanger design of MR-JT refrigerator, it has been rarely discussed so far. In this paper, condensation and evaporation heat transfer coefficients of mixed refrigerant are measured in a microchannel heat exchanger. Printed Circuit Heat Exchanger (PCHE) has been developed as a compact microchannel heat exchanger and used in the experiment. Several two-phase heat transfer coefficient correlations are examined to discuss the experimental measurement results. The result of this paper shows that cryogenic mixed refrigerant heat transfer coefficients can be estimated by conventional two-phase heat transfer coefficient correlations.