Boiling Heat Transfer With Freon 11 (R11) in Brazed Aluminum, Plate-Fin Heat Exchangers

1983 ◽  
Vol 105 (3) ◽  
pp. 605-610 ◽  
Author(s):  
J. M. Robertson ◽  
P. C. Lovegrove

The results of laboratory experiments with Freon 11 (R11) flowing in an electrically heated, serrated-fin test section to measure local boiling coefficients over a wide range of vapor quality, with mass fluxes up to 150 kg/m2 s, heat fluxes to 4 kW/m2, and pressure from 3–7 bar, are reported. These low mass and heat fluxes reflect the industrial process application of these heat exchangers where exceedingly small temperature differences may exist between streams. Results are compared with the very similar boiling characteristics previously reported elsewhere for the same test section, with liquid nitrogen as a test fluid under comparable flow conditions. A simple method using the Reynolds number of the total flow regarded as a liquid has been used to correlate boiling heat transfer coefficients with quality for both fluids. The use of a liquid-film flow model to produce a nondimensional correlation connecting the Nusselt, Reynolds, and Prandtl numbers of the film is discussed.

Author(s):  
Todd M. Bandhauer ◽  
Taylor A. Bevis

The principle limit for achieving higher brightness of laser diode arrays is thermal management. State of the art laser diodes generate heat at fluxes in excess of 1 kW cm−2 on a plane parallel to the light emitting edge. As the laser diode bars are packed closer together, it becomes increasingly difficult to remove large amounts of heat in the diminishing space between neighboring diode bars. Thermal management of these diode arrays using conduction and natural convection is practically impossible, and, therefore, some form of forced convective cooling must be utilized. Cooling large arrays of laser diodes using single-phase convection heat transfer has been investigated for more than two decades by multiple investigators. Unfortunately, either large fluid temperature increases or very high flow velocities must be utilized to reject heat to a single phase fluid, and the practical threshold for single phase convective cooling of laser diodes appears to have been reached. In contrast, liquid-vapor phase change heat transport can occur with a negligible increase in temperature and, due to a high enthalpy of vaporization, at comparatively low mass flow rates. However, there have been no prior investigations at the conditions required for high brightness edge emitting laser diode arrays: >1 kW cm−2 and >10 kW cm−3. In the current investigation, flow boiling heat transfer at heat fluxes up to 1.1 kW cm−2 was studied in a microchannel heat sink with plurality of very small channels (45 × 200 microns) using R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio in the vicinity of the laser diode. To characterize the heat transfer performance, a test facility was constructed that enabled testing over a range of fluid saturation temperatures (15°C to 25°C). Due to the very small geometric features, significant heat spreading was observed, necessitating numerical methods to determine the average heat transfer coefficient from test data. This technique is crucial to accurately calculate the heat transfer coefficients for the current investigation, and it is shown that the analytical approach used by many previous investigations requires assumptions that are inadequate for the very small dimensions and heat fluxes observed in the present study. During the tests, the calculated outlet vapor quality exceeded 0.6 and the base heat flux reached a maximum of 1.1 kW cm−2. The resulting experimental heat transfer coefficients are found to be as large a 58.1 kW m−2 K−1 with an average uncertainty of ±11.1%, which includes uncertainty from all measured and calculated values, required assumptions, and geometric discretization error from meshing.


Author(s):  
Kwang-Hyun Bang ◽  
Kun-Eui Hong ◽  
In-Seon Hwang

This paper reports an experimental study on flow boiling of water in a minichannel. Flow boiling heat transfer coefficients and pressure drops were measured and the data were compared with existing correlations. The effect of pressure was the major objectives in this study and the range of pressure was 1 to 18 bars. The experimental apparatus consisted mainly of a minichannel test section, gear pump, pre-heater, pressurizer, condenser and evaporator. The evaporator was used for variation of vapor quality at the inlet of test section. The pressurizer controls the desired system pressure. The test section is a round tube of 1.73 mm inside diameter, made of 316 stainless steel. The test section and the evaporator tubes were heated by DC electric current through the tubes. The measured flow boiling heat transfer coefficients showed two distinct regions; relatively high heat transfer coefficients at low vapor quality and lower heat transfer coefficients at higher vapor quality. This observation implies the change of flow regime, slug to annular flow. Comparisons of the experimental data and the prediction of correlations (Gungor & Winterton, 1987; Tran et al., 1996; Kandlikar, 2003) showed large discrepancy in both regions.


Author(s):  
Koichi Hata ◽  
Suguru Masuzaki

The subcooled boiling heat transfer (HT) and the steady-state critical heat fluxes (CHFs) in a short SUS304-tube with twisted-tape insert are systematically measured for mass velocities (G = 4016 to 13850 kg/m2s), inlet liquid temperatures (Tin = 285.82 to 363.96 K), outlet pressures (Pout = 764.76 to 889.02 kPa) and exponentially increasing heat input (Q = Q0exp(t/τ), τ = 8.5 s) by the experimental water loop comprised of a multistage canned-type circulation pump controlled by an inverter. The SUS304 test tube of inner diameter (d = 6 mm), heated length (L = 59.5 mm), effective length (Leff = 49.1 mm), L/d (= 9.92), Leff/d (= 8.18) and wall thickness (δ = 0.5 mm) with average surface roughness (Ra = 3.18 μm) is used in this work. The SUS304 twisted tape with twist ratio, y [= H/d = (pitch of 180° rotation)/d], of 3.39 is used. The relation between inner surface temperature and heat flux for the SUS304-tube with the twisted-tape insert are clarified from non-boiling to CHF. The subcooled boiling heat transfer for SUS304-tube with the twisted-tape insert is compared with our empty SUS304-tube data and the values calculated by our and other workers’ correlations for the subcooled boiling heat transfer. The influences of the twisted-tape insert and the swirl velocity on the subcooled boiling heat transfer and the CHFs are investigated into details and the widely and precisely predictable correlations of the subcooled boiling heat transfer and the CHFs for turbulent flow of water in the SUS304-tube with twisted-tape insert are given based on the experimental data. The correlations can describe the subcooled boiling heat transfer coefficients and the CHFs obtained in this work within −25 to +15% difference.


Author(s):  
Gilberto Moreno ◽  
Sreekant Narumanchi ◽  
Charles King

This fundamental study characterizes the pool boiling performance of a new refrigerant, HFO-1234yf (hydrofluoroolefin 2,3,3,3-tetrafluoropropene). The similarities in thermophysical properties with HFC-134a and low global warming potential make HFO-1234yf the prospective next generation refrigerant in automotive air-conditioning systems. This study examines the possibility of using this refrigerant for two-phase cooling of hybrid and electric vehicle power electronic components. Pool boiling experiments were conducted with HFO-1234yf and HFC-134a at system pressures ranging from 0.7 to 1.7 MPa using horizontally oriented 1 cm2 heat sources. Results show that the boiling heat transfer coefficients of HFO-1234yf and HFC-134a are nearly identical at lower heat fluxes. HFO-1234yf yielded lower heat transfer coefficients at higher heat fluxes and lower critical heat flux (CHF) as compared with HFC-134a. To enhance boiling heat transfer, a copper microporous coating was applied to the test surfaces. The coating provided enhancement to both the boiling heat transfer coefficients and CHF, for both refrigerants, at all tested pressures. Increasing pressure decreases the level of heat transfer coefficient enhancements while increasing the level of CHF enhancements.


2005 ◽  
Vol 127 (8) ◽  
pp. 897-902 ◽  
Author(s):  
Majid Bazargan ◽  
Daniel Fraser ◽  
Vijay Chatoorgan

Heat transfer to supercritical water and buoyancy∕natural convection effects are becoming increasingly important areas of research due to current trends in nuclear reactor design and supercritical water oxidation facilities. A pilot-scale supercritical water oxidation loop was constructed at the University of British Columbia. For this work, the facility was used to study the relative importance of buoyancy effects on supercritical water flowing in a horizontal pipe. Local heat transfer coefficients at the top and bottom surfaces of the horizontal test section were systematically measured over a wide range of conditions at supercritical pressures between 23 to 27 MPa, uniform heat fluxes were up to 310kW∕m2, and the mass flux ranged from 330 to 1230kg∕m2s. It was found that neglecting buoyancy effects could cause large discrepancies between the predictions of available empirical correlations and the experimental data. The data was used to assess available criteria for the buoyancy-free region during horizontal supercritical fluid flows. The criterion of Petukhov and Polyakov, which, for the range of parameters in this study, was found to be accurate in predicting the onset of buoyancy effects. The experimental investigation is confined to supercritical flows with heat addition only. Hence, no heat loss conditions at supercritical temperatures were investigated.


Author(s):  
Chong Chen ◽  
Pu-zhen Gao

Experimental investigations on boiling heat transfer coefficients of boiling flows in rectangular narrow channel under rolling motion condition are performed. The cross section of the testing rectangular narrow channel is 2×40 mm, and the mechanical rolling thermal-hydraulic experimental facility is used in the experimental research of boiling heat transfer characteristics. Deionized water is used as the working fluid. The results show that the amplitude of boiling heat transfer coefficients of rectangular narrow channel increases with increasing rolling amplitude and rolling period of the rolling platform, the time average boiling heat transfer coefficients of test section in rolling motion are equal to the coefficients of the test section at equilibrium position, and with the increase of rolling amplitude and rolling period the time average boiling heat transfer coefficient almost unchanged. The amplitude of boiling heat transfer coefficients increases with increasing heat flux and flow rate, while decreases with the increase of system pressure. The curve of boiling heat transfer coefficient fluctuations of rectangular narrow channel is close to sine or cosine curve when the rolling period less than 15 seconds.


Author(s):  
Hakim Maloufi ◽  
Hanqing Xie ◽  
Andrew Zopf ◽  
William Anderson ◽  
Christian Langevin ◽  
...  

Currently, there is a number of Generation-IV SuperCritical Water-cooled nuclear-Reactor (SCWR) concepts under development worldwide. These high temperature and pressure reactors will have significantly higher operating parameters compared to those of current water-cooled nuclear-power reactors (i.e., “steam” pressures of about 25 MPa and “steam” outlet temperatures up to 625 °C). Additionally, SCWRs will have a simplified flow circuit in which steam generators, steam dryers, steam separators, etc. will be eliminated, as the steam will be flowing directly to a steam turbine. In support of developing SCWRs studies are being conducted on heat transfer at SuperCritical Pressures (SCPs). Currently, there are very few experimental datasets for heat transfer at SCPs in power-reactor fuel bundles to a coolant (water) available in open literature. Therefore, for preliminary calculations, heat-transfer correlations developed with bare-tube data can be used as a conservative approach. Selected empirical heat-transfer correlations, based on experimentally obtained datasets, have been put forward to calculate Heat Transfer Coefficients (HTCs) in forced convective in various fluids, including water at SCPs. The Mokry et al. correlation (2011) has shown a good fit for experimental data at supercritical conditions within a wide range of operating conditions in Normal and Improved Heat-Transfer (NHT and IHT) regimes. However, it is known that a Deteriorated Heat-Transfer (DHT) regime appears in bare tubes earlier than that in bundle flow geometries. Therefore, it is important to know if bare-tube heat-transfer correlations for SCW can predict HTCs at heat fluxes beyond those defined as starting of DHT regime in bare tubes. The Mokry et al. (2011) correlation fits the best SCW experimental data for HTCs and inner wall temperature for bare tubes at SCPs within the NHT and IHT regimes. However, this correlation might have problems with convergence of iterations at heat fluxes above 1000 kW/m2.


Author(s):  
Yutaka Ebihara ◽  
Atsushi Katsuta ◽  
Yasuo Koizumi ◽  
Hiroyasu Ohtake

Heat transfer and flow behavior in the mini rod bank were examined. The tubes are simulated with a 1 mm diameter nickel wire. The tube bank was composed of the 5×5 square-lattice array and the 5×5 staggered array. The tube banks were arranged in the flow channel of 30 mm wide or 15 mm wide, 15 mm high and 480 mm long. Water was used as the test fluid. A flow rate was varied in the range of the Reynolds number Re = uD/ν of 1 ∼ 800, where D is the tube diameter. The approaching velocity of fluid in the channel was in the range of 0.0036 m/s ∼ 0.68 m/s. Experiments were performed at atmospheric pressure. The measured heat transfer coefficients of the rows after the second row were lower than those of the first row and the difference between those increased as the Reynolds number was increased. The difference turned to decrease around Reynolds number = 50 in the 15 mm wide test section experiments of the square–lattice array and around Reynolds number = 200 in the 30 mm wide test section experiments of the staggered array. The heat transfer coefficients reached back to the first row value around Re = 400 in the former experiments. It was confirmed through the present results and the previous results that the heat transfer in the rear rows is deteriorated by the flow stagnation in the wake region of the preceding rod and the deterioration is recovered as the Reynolds number is increased since the wake region becomes disturbed.


Author(s):  
Koichi Hata ◽  
Suguru Masuzaki

The subcooled boiling heat transfer and the steady state critical heat fluxes (CHFs) in a short vertical SUS304-tube for the flow velocities (u = 17.28 to 40.20 m/s), the inlet liquid temperatures (Tin = 293.30 to 362.49 K), the inlet pressures (Pin = 842.90 to 1467.93 kPa) and the exponentially increasing heat input (Q = Q0 exp(t/τ), τ = 10 s) were systematically measured by the experimental water loop comprised of a multistage canned-type circulation pump with high pump head. The SUS304 test tubes of inner diameters (d = 3 and 6 mm), heated lengths (L = 33 and 59.5 mm), effective lengths (Leff = 23.3 and 49.1 mm), L/d (= 11 and 9.92), Leff/d (= 7.77 and 8.18), and wall thickness (δ = 0.5 mm) with average surface roughness (Ra = 3.18 μm) are used in this work. The inner surface temperature and the heat flux from non-boiling to CHF were clarified. The subcooled boiling heat transfer for SUS304 test tube was compared with our Platinum test tube data and the values calculated by other workers’ correlations for the subcooled boiling heat transfer. The influence of flow velocity on the subcooled boiling heat transfer and the CHF is investigated into details and the widely and precisely predictable correlation of the subcooled boiling heat transfer for turbulent flow of water in a short vertical SUS304-tube is given based on the experimental data. The correlation can describe the subcooled boiling heat transfer coefficients obtained in this work within 15% difference. Nucleate boiling surface superheats for the SUS304 test tube become very high. Those at the high liquid Reynolds number are close to the lower limit of Heterogeneous Spontaneous Nucleation Temperature. The dominant mechanisms of the flow boiling CHF in a short vertical SUS304-tube are discussed.


Author(s):  
Tong Lv ◽  
Boren Zheng ◽  
Wei Li ◽  
Zahid Ayub

Abstract Corrugated plate heat exchangers are increasingly used in two-phase flow applications for their flexible and compact size and the efficient heat transfer performance. This paper presents a review of recent studies on the subject and creates a database containing 533 data points from experiment studies. The collected database covers seven working fluids, a wide range of vapor quality (both mean and local) 0.01–0.94, heat flux 0.5–46 kW m−2, mass flux 5.5–137 kg m−2 s−1, chevron angle 30°–70°, and hydraulic diameter 1.7–4.0 mm. Based on the database a brief comparison between several previous correlations are discussed. A new prediction method for flow boiling heat transfer coefficient is generated by multiple regression analysis and modifying an existing correlation. It was observed that the modified correlation shows a better agreement and predicts 74.3% of data points within ±30% error band and 94.9% within ±50% error band.