Heat Transfer to a Fluid in Radial, Outward Flow Between Two Coaxial Stationary or Corotating Disks

1983 ◽  
Vol 105 (3) ◽  
pp. 519-526 ◽  
Author(s):  
N. V. Suryanarayana ◽  
T. Scofield ◽  
R. E. Kleiss

An experimental study of heat transfer rates to air flowing radially outward between two coaxial, corotating disks was made. Heat transfer data were obtained for five mass flow rates with stationary disks and four mass flow rates and five rotational speeds with rotating disks. Rotation of the disks slightly decreased the average Nusselt numbers compared with the average Nusselt numbers without rotation at the highest speed of rotation (600 rmp), but at lower speeds no consistent trends were observed. The average Nusselt numbers, with and without rotation, can be related as Nu = 0.0529 Re0.71 and the local Nusselt number as Nu = 0.124 Re0.608.

2018 ◽  
Vol 144 ◽  
pp. 04012
Author(s):  
Akarsh Kumar ◽  
Ujjawal Sureka ◽  
Shiva Kumar

In the present study numerical analysis of enhancement in heat transfer characteristics in a double pipe heat exchanger is studied using a holed twisted tape.The twisted tape with a constant twist ratio is inserted in a double pipe heat exchanger. Holes of diameter 1mm, 3 mm and 5 mm were drilled at regular pitch throughout the length of the tape. Numerical modeling of a double pipe heat exchanger with the holed twisted tape was constructed considering hot fluid flowing in the inner pipe and cold fluid through the annulus.Simulation was done for varied mass flow rates of hot fluid in the turbulent condition keeping the mass flow rate of cold fluid being constant. Thermal properties like Outlet temperatures, Nusselt number, overall heat transfer coefficient, heat transfer rate and pressure drop were determined for all the cases. Results indicated that normaltwisted tape without holes performed better than the bare tube. In the tested range of mass flow rates the average Nusselt number and heat transfer rate were increased by 85% and 34% respectively. Performance of Twisted tape with holes was slightly reduced than the normal twisted tape and it deteriorated further for higher values hole diameter. Pressure drop was found to be higher for the holed twisted tape than the normal tape.


Author(s):  
Anika Steurer ◽  
Rico Poser ◽  
Jens von Wolfersdorf ◽  
Stefan Retzko

The present study deals with the application of the transient thermochromic liquid crystal (TLC) technique in a flow network of intersecting circular passages as a potential internal turbine component cooling geometry. The investigated network consists of six circular passages with a diameter d = 20mm that intersect coplanar at an angle θ = 40°, the innermost in three, the outermost in one intersection level. Two additional non-intersecting passages serve as references. Such a flow network entails specific characteristics associated with the transient TLC method that have to be accounted for in the evaluation process: the strongly curved surfaces, the mixing and mass flow redistribution at each intersection point, and the resulting gradients between the wall and passage centerline temperatures. All this impedes the choice of a representative fluid reference temperature, which results in deviations using established evaluation methods. An alternative evaluation approach is introduced, which is supported by computational results obtained from steady-state three-dimensional RANS simulations using the SST turbulence model. The presented analysis uncouples local heat transfer coefficients from actually measured local temperatures but uses the time information of the thermocouples instead that represents the fluid temperature step change and evolution along the passages. This experimental time information is transferred to the steady-state numerical bulk temperatures, which are finally used as local references to evaluate the transient TLC experiments. As effective local mass flow rates in the passage sections are considered, the approach eventually allows for a conclusion whether heat transfer is locally enhanced due to higher mass flow rates or the intersection effects.


Author(s):  
Vahid Madadi ◽  
Touraj Tavakoli ◽  
Amir Rahimi

AbstractThe energy and exergy performance of a parabolic dish collector is investigated experimentally and theoretically. The effect of receiver type, inlet temperature and mass flow rate of heat transfer fluid (HTF), receiver temperature, receiver aspect ratio and solar radiation are investigated. To evaluate the effect of the receiver aperture area on the system performance, three aperture diameters are considered. It is deduced that the fully opened receivers have the greatest exergy and thermal efficiency. The cylindrical receiver has greater energy and exergy efficiency than the conical one due to less exergy destruction. It is found that the highest exergy destruction is due to heat transfer between the sun and the receivers and counts for 35 % to 60 % of the total wasted exergy. For three selected receiver aperture diameters, the exergy efficiency is minimum for a specified HTF mass flow rate. High solar radiation allows the system to work at higher HTF inlet temperatures. To use this system in applications that need high temperatures, in cylindrical and conical receivers, the HTF mass flow rates lower than 0.05 and 0.09 kg/s are suggested, respectively. For applications that need higher amounts of energy content, higher HTF mass flow rates than the above mentioned values are recommended.


1974 ◽  
Vol 96 (3) ◽  
pp. 282-288 ◽  
Author(s):  
K. R. Hedges ◽  
P. G. Hill

An experimental study has been made of compressible jet mixing in an axisymmetric ejector of converging-diverging geometry. The mass flow ratio was in the range 1.3 to 2.6 and the nozzle exit Mach number was 1.82. Ejector performance characteristics were obtained as well as measurements of pressure and velocity distribution over a range of mass flow rates. The experimental results were used to test the reliability of the analytical model of the flow described in Part I of the paper.


Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6543
Author(s):  
Mieczysław Dzierzgowski

Laboratory measurements and analyses conducted in a wide range of changes of water temperature and mass flow rate for different types of radiators allowed to provides limitations and assessment of the current radiators heat transfer model according to EN 442. The inaccuracy to determinate the radiator heat output according to EN 442, in case of low water mass flow rates may achieve up to 22.3% A revised New Extended Heat Transfer Model in Radiators NEHTMiRmd is general and suitable for different types of radiators both new radiators and radiators existing after a certain period of operation is presented. The NEHTMiRmd with very high accuracy describes the heat transfer processes not only in the nominal conditions—in which the radiators are designed, but what is particularly important also in operating conditions when the radiators water mass flow differ significantly from the nominal value and at the same time the supply temperature changes in the whole range radiators operating during the heating season. In order to prove that the presented new model NEHTMiRmd is general, the article presents numerous calculation examples for various types of radiators currently used. Achieved the high compatibility of the results of the simulation calculations with the measurement results for different types of radiators: iron elements (not ribbed), plate radiators (medium degree ribbed), convectors (high degree ribbed) in a very wide range of changes in the water mass flow rates and the supply temperature indicates that a verified NEHTMiRmd can also be used in designing and simulating calculations of the central heating installations, for the rational conversion of existing installations and district heating systems into low temperature energy efficient systems as well as to directly determine the actual energy efficiency, also to improve the indications of the heat cost allocators. In addition, it may form the basis for the future modification of the European Standards for radiator testing.


Author(s):  
Y. S. Muzychka ◽  
M. Ghobadi

Heat transfer in micro and mini-scale ducts and channels is considered. In particular, issues of thermal performance are considered in systems with constant wall temperature at low to moderate Reynolds numbers or small dimensional scales which lead to conditions characteristic of thermally fully developed flows or within the transition region leading to thermally fully developed flows. An analysis of two approaches to representing experimental data is given. One using the traditional Nusselt number and another using the dimensionless mean wall flux. Both approaches offer a number of advantages and disadvantages. In particular, it is shown that while good data can be obtained which agree with predicted heat transfer rates, the same data can be problematic if one desires a Nusselt number. Other issues such as boundary conditions pertaining to measuring thermally developing and fully developed flow Nusselt numbers are also discussed in detail.


Author(s):  
Muhammad Ali Kamran ◽  
Shahryar Manzoor

A comprehensive experimental study on the effects of different operating parameters on the efficiency of tesla turbine is reported. A bladeless turbine with nine discs and up to four turbine inlets was used, with water as the working fluid. The parameters investigated are the nozzle angle, number of turbine inlets and mass flow rates. Contrary to earlier studies, an effort was made to determine the performance under varying loading conditions, and hence identify the complete performance characteristics. The study revealed that efficiency of the turbine increases at lower nozzle angles and higher number of turbine inlets. It was observed that the nozzle angle becomes a significant parameter when the number of turbine inlets is increased. Efficiencies up to 78% were achieved when the working fluid entered the turbine through two nozzles at an angle of 7°. It was also noted that the turbine is most efficient at the designed mass flow rate, and the efficiency reduces appreciably if lower mass flow rates are fed to the turbine. The results obtained are an important contribution to the available knowledge and can be used as design references for further studies.


1988 ◽  
Vol 110 (2) ◽  
pp. 90-97 ◽  
Author(s):  
R. Celentano ◽  
R. Kirchner

An experimental study was conducted on the operation of a “once-through” thermosiphon system. This new type of natural circulation system, unlike the standard thermosiphon system, heats the collector fluid in one pass without any recirculation. An electrically heated manifold was used to simulate the useful solar gain. Power was varied with time in 22 half-hour increments to simulate the actual daily useful solar gain. The time-dependent responses of the system in terms of temperatures and mass flow rates were recorded and plotted. The response time for mass flow and temperature to approach steady state varied directly with the size of the power step. Two experiments were conducted; one which tracked mass flows and outlet temperatures for variable useful solar gains, and a second which tracked mass flows at constant outlet temperature for variable useful solar gains.


2018 ◽  
Vol 141 (3) ◽  
Author(s):  
Eric C. Okonkwo ◽  
Muhammad Abid ◽  
Tahir A. H. Ratlamwala ◽  
Serkan Abbasoglu ◽  
Mustafa Dagbasi

This study presents an experimental nanoparticle synthesis and the numerical analysis of a parabolic trough collector (PTC) operating with olive leaf synthesized TiO2/water nanofluid. The PTC is modeled after the LS-2 collector for various operating conditions. An analysis of the heat transfer and entropy generation in the PTC is carried out based on the first and second laws of thermodynamics for various parameters of nanoparticle volumetric concentration (0 ≤ φ ≤ 8%), mass flow rate (0.1 ≤ m˙ ≤ 1.1 kg/s), and inlet temperatures (350–450 K) under turbulent flow regime. The effect of these parameters is evaluated on the Nusselt number, thermal losses, heat convection coefficient, outlet temperature, pressure drop, entropy generation rate, and Bejan number. The results show that the values of the Nusselt number decrease with higher concentrations of the nanoparticles. Also, the addition of nanoparticles increases the heat convection coefficient of the nanofluid compared to water. The thermal efficiency of the system is improved with the use of the new nanofluid by 0.27% at flow rates of 0.1 kg/s. The entropy generation study shows that increasing the concentration of nanoparticles considerably decreases the rate of entropy generation in the system. It is also observed that increasing the volumetric concentration of nanoparticles at low mass flow rates has minimal effect on the rate of entropy generation. Finally, a correlation that provides a value of mass flow rate that minimizes the entropy generation rate is also presented for each values of inlet temperature and nanoparticle volumetric concentration.