Free Convection in a Vertical Annulus With Constant Heat Flux on the Inner Wall

1983 ◽  
Vol 105 (3) ◽  
pp. 454-459 ◽  
Author(s):  
M. Keyhani ◽  
F. A. Kulacki ◽  
R. N. Christensen

Heat transfer measurements are presented for free convection in a vertical annulus wherein the inner cylinder is at constant surface heat flux and the outer cylinder is at constant temperature. Overall heat transfer data are corrected for thermal radiation in the annulus. Rayleigh numbers span the conduction, transition and boundary layer regimes of flow, and average heat transfer coefficients are obtained with air and helium as the working fluids. The range of Rayleigh number is 103 < Ra < 2.3 × 106; the radius ratio is 4.33; and the aspect ratio (cylinder length divided by annular gap) is 27.6. Energy transferred by thermal radiation varies with Rayleigh number and working fluid. With air, thermal radiation can account for up to 50 percent of the heat transfer. With helium, radiation can account for up to 30 percent of the heat transfer rate. The results of the study provide data relevant to the design and performance assessment of spent fuel packages as part of the National Waste Terminal Storage Program for nuclear waste isolation.

Author(s):  
C. Aprea ◽  
A. Greco ◽  
G. P. Vanoli

R22 is the most widely employed HCFC working fluid in vapour compression plant. HCFCs must be replaced within 2020. Major problems arise with the substitution of the working fluids, related to the decrease in performance of the plant. Therefore, extremely accurate design procedures are needed. The relative sizing of each of the components of the plant is crucial for cycle performance. For this reason, the knowledge of the new fluids heat transfer characteristics in condensers and evaporators is required. The local heat transfer coefficients and pressure drop of pure R22 and of the azeotropic mixture R507 (R125-R143a 50%/50% in weight) have been measured during convective boiling. The test section is a smooth horizontal tube made of a with a 6 mm I.D. stainless steel tube, 6 m length, uniformly heated by Joule effect. The effects of heat flux, mass flux and evaporation pressure on the heat transfer coefficients are investigated. The evaporating pressure varies within the range 3 ÷10 bar, the refrigerant mass flux within the range 200 ÷ 1000 kg/m2s, the heat flux within 0 ÷ 44 kW/m2. A comparison have been carried out between the experimental data and those predicted by means of the most credited literature relationships.


Author(s):  
Ankit Kalani ◽  
Satish G. Kandlikar

Flow boiling with microchannel can dissipate high heat fluxes at low surface temperature difference. A number of issues, such as instabilities, low critical heat flux (CHF) and low heat transfer coefficients, have prevented it from reaching its full potential. A new design incorporating open microchannels with uniform and tapered manifold (OMM) was shown to mitigate these issues successfully. Distilled, degassed water at 80 mL/min is used as the working fluid. Plain and open microchannel surfaces are used as the test sections. Heat transfer and pressure drop performance for uniform and tapered manifold with both the surfaces are discussed. A low pressure drop of 7.5 kPa is obtained with tapered manifold and microchannel chip at a heat flux of 263 W/cm2 without reaching CHF. The pressure drop data is further compared with the homogenous model and the initial results are presented.


2017 ◽  
Vol 25 (02) ◽  
pp. 1750013 ◽  
Author(s):  
Pham-Quang Vu ◽  
Kwang-Il Choi ◽  
Jong-Taek Oh ◽  
Honggi Cho

The condensation heat transfer coefficients and pressure drops of R410A and R22 flowing inside a horizontal aluminum multiport mini-channel tube having 18 channels are investigated. Experimental data are presented for the range of vapor quality from 0.1 to 0.9, mass flux from 50 to 500[Formula: see text]kg/m2s, heat flux from 3 to 15[Formula: see text]kW/m2 and the saturation temperature at 48[Formula: see text]C. The pressure drop across the test section was directly measured by a differential pressure transducer. At a small scale, the noncircular cross-sections can enhance the effect of the surface tension. The average heat transfer coefficient increased with the increase of vapor quality, mass flux and heat flux. Under the same test conditions, the heat transfer coefficients of R22 are higher than those for R410A, the pressure drops for R410A are 7–19% lower than those of R22. The lower pressure drop of R410A has an important advantage as an alternative working fluid for R22 in air-conditioning and heat pump systems.


Author(s):  
B.S. Larkin

This paper reports tests on a wickless heat pipe to be used for transporting heat from the ground to protect an electronic package from low ambient temperatures. Evaporating heat transfer coefficients were measured for low heat fluxes where the behaviour of the evaporating film is unpredictable. The effects of type of working fluid, heat flux, charge quantity and tube inclination were investigated.


1985 ◽  
Vol 107 (3) ◽  
pp. 611-623 ◽  
Author(s):  
M. Keyhani ◽  
F. A. Kulacki ◽  
R. N. Christensen

Free convection in two vertical, enclosed rod bundles has been experimentally investigated for a wide range of Rayleigh numbers. A uniform power dissipation per unit length is supplied to each rod, and the enclosing outer cylinder is maintained at constant temperature. Nusselt numbers for each rod, as well as an overall value for each bundle, have been obtained as a function of Rayleigh number. Comparison of the results for air and water as the working fluid indicate that, for a fixed Rayleigh number, an increase in the Prandtl number produces a reduction in the Nusselt number. This is contrary to what has been reported for vertical cavities and is attributed to curvature effects. Furthermore, the data reveal the interesting fact that it is quite possible for the individual rods in the bundle to exchange energy with the working fluid via different but coexisting regimes at a given power dissipation. Also, as the Rayleigh number is increased, the rods each tend to assume nearly the same heat transfer coefficient. Finally, a correlation for the overall convective Nusselt number is developed in terms of Rayleigh number and geometric parameters.


1967 ◽  
Vol 89 (3) ◽  
pp. 258-268 ◽  
Author(s):  
A. W. Black ◽  
E. M. Sparrow

An experimental investigation, supported by analysis, was performed to determine the heat transfer characteristics for turbulent flow in a circular tube with circumferentially varying wall temperature and wall heat flux. Air was the working fluid. The desired boundary conditions were achieved by electric heating within the wall of a tube whose thickness varied circumferentially. In this way, ratios of maximum-to-minimum wall heat flux as large as two were attained. Local heat transfer coefficients, deduced from the experimental data, display a circumferential variation that is substantially smaller than the heat flux variation. In general, lower heat transfer coefficients correspond to circumferential locations of greater heating, while higher coefficients correspond to locations of lesser heating. The predictions of prior analyses appear to overestimate the circumferential variation of the heat transfer coefficient. A specially designed probe was employed to measure the radial and circumferential temperature distributions within the flowing airstream. On the basis of these measurements, as well as from the heat transfer results, it is concluded that, in the neighborhood of the wall, the tangential turbulent diffusivity is greater than the radial turbulent diffusivity. The axial thermal development was found to be more rapid on the lesser-heated side of the tube than on the greater-heated side. Experimentally determined circumferential-average heat transfer coefficients agreed well with the predictions of analysis.


Author(s):  
Suraj Joottu Thiagarajan ◽  
Sreekant Narumanchi ◽  
Charles King ◽  
Wei Wang ◽  
Ronggui Yang

The National Renewable Energy Laboratory (NREL) is leading a national effort to develop next-generation cooling technologies for hybrid vehicle electronics, as part of the Advanced Power Electronics and Electrical Machines program area in the U.S. Department of Energy’s (DOE’s) Vehicle Technologies Program. The overarching goal is to reduce the size, weight, and cost of power electronic modules that convert direct current from the batteries to alternating current for the motor, and vice versa. Aggressive thermal management techniques help in achieving the goals of increased power density and reduced weight and volume, while keeping the chip temperatures within acceptable limits. The viability of aggressive cooling schemes such as spray and jet impingement in conjunction with enhanced surfaces is being explored as part of the program. In this work, we present results from a series of experiments with pool and spray boiling on enhanced surfaces, such as a microporous layer of copper and copper nanowires, using HFE-7100 as the working fluid. Spray impingement on the microporous coated surface showed an enhancement of 100%–300% in the heat transfer coefficient at a given wall superheat with respect to spray impingement on a plain surface under similar operating conditions. The critical heat flux also increased by 7%–20%, depending on the flow rates. Heat transfer coefficients obtained on the nanowire-grown surface are considerably better than those obtained on the plain surface, although the enhancement is lower than those obtained on the microporous surface. The critical heat flux is also considerably lower for the nanowire surface than for the plain surface.


Author(s):  
Naushad Hasin Khan ◽  
M. A. Hassan

The numerical investigation of laminar natural convection of viscoplastic fluid in a two dimensional square enclosure has been reported in this work. The enclosed fluid is subjected to partial bi-heating from the bottom wall and symmetrical cooling from the sides under steady condition. Yield stress fluid has been heated through two heaters symmetrically placed on the either side of the centre of the bottom wall of the square enclosure. The viscoplastic fluid is the one which requires a minimum critical stress called yield stress to flow otherwise behave as a solid, have been modeled with Herschel–Bulkley model. Such fluids have significant technological relevance due to its wide application ranging from cosmetics products, food processing industries, pharmaceuticals to natural occurring like flow of debris and lava. The solution of governing partial differential equations has been approached using finite volume based formulation. Non uniform set of grid has been used. The effects of yield stress, heat flux, and power law index on the flow and thermal characteristics of the free convection of Herschel-Bulkley fluids have been studied for a particular value of Prandtl number. The flow and thermal fields have been investigated for the following ranges of conditions: Rayleigh number varies between 103 and 106 whereas power law index ranges from 0 to 1. The heat transfer characteristic has been depicted with the help of isotherms and the flow field has been illustrated by streamlines. The onset of convection is substantially delayed due to presence of yield stress of the fluid. This results in enhanced critical Rayleigh number for onset of convection. With increase in the Yield number in turn yield stress, results in the weakening of heat transfer through convection and at a particular relatively higher value of Yield number the heat transfer is solely taken place by conduction mode. Due to the symmetry in both heating and boundary conditions, the obtained isotherms and streamlines of the right half are symmetrical to the left half of the square enclosure. The conductive mode of heat transfer becomes dominated by increasing yield stress and reducing Ra and vice versa. The simultaneous presence of yielded and unyielded region presents an interesting pattern in the convection zone. Furthermore, it can be seen that rise in heat flux, in turn Ra, promotes the buoyancy driven circulation of viscoplastic fluid i.e. enhances natural convective heat transfer. In addition, the effect of power law index has been investigated. Power law index has little effect on thermal distribution and flow field.


Author(s):  
K. H. Bang ◽  
T. Y. Yoon

This paper reports an experimental study of flow boiling in a microchannel and this work has been focused on the investigation on the effect of operating pressure. The experimental apparatus consisted mainly of peristaltic pump, preheater, microchannel test tube, and vacuum chamber for control of operating pressure. Deionized water was used as the working fluid. The test section was a round tube of 310 μm inside diameter, made of 304 stainless steel. The experiment has been performed for the conditions of heat flux of 35∼85 kW/m2, mass flux of 200∼300 kg/m2s (160∼250 of liquid Reynolds numbers), and the operating pressure of 10∼20 kPa. The measured flow boiling heat transfer coefficients in the microchannel were in the range of 3.0 to 27 kW/m2K and the experimental data showed that the flow boiling heat transfer coefficients in microchannels were affected mainly by the wall heat flux and the operating pressure.


Author(s):  
Aranya Chauhan ◽  
Satish G. Kandlikar

The efficient cooling of servers in data center offers unique challenge to reduce the worldwide energy consumption and fluid inventory. The presented work addresses the great potential of a thermosiphon system using two-phase heat transfer process which improves the efficiency of the system by significantly improving the heat dissipation ability. The latent heat transfer is more effective than sensible heat. However, the system performance is limited by Critical Heat Flux (CHF) and Heat Transfer Coefficients (HTC). An increase in CHF offers wide temperature operating range while HTC defines the efficiency of the process. In the current design of the cooling solution, a manifold with a taper is employed over the heater surface to guide vapor away from the surface along the flow length. The incoming liquid flows over the heating surface unobstructed developing separate liquid-vapor pathways. A 6° taper manifold is analyzed with HFE7000 as the working fluid. The performance of thermosiphon loop is evaluated for three different liquid volumes resulting in three different liquid heads available in the thermosiphon loop. The respective heat flux and HTC are compared. The maximum heat dissipation was observed for 325ml liquid with a microchannel chip resulting in a CHF of 42.1W/cm2 at a wall superheat of 17.8°C. The observed performance data shows that thermosiphon loop is an eligible replacement for conventional single-phase cooling techniques used for CPU cooling in data centers.