Measurements in Vertical Plane Turbulent Plumes

1989 ◽  
Vol 111 (1) ◽  
pp. 69-77 ◽  
Author(s):  
B. R. Ramaprian ◽  
M. S. Chandrasekhara

Mean-flow and turbulence measurements have been obtained in two-dimensional vertical turbulent plumes in a nominally still ambient. The plumes were generated by injecting hot water vertically upwards from the bottom of a reservior containing cold water. A two-component Laser Doppler Anemometer (LDA) and a “cold-film” resistance thermometer were used to obtain instantaneous velocity and temperature measurements in the plume. The present mean-flow measurements have confirmed many of the earlier measurements on plane plumes, but have also indicated some important differences. The use of the two-component LDA made it possible to obtain data on turbulent intensities, turbulent fluxes and other details of the structure of turbulence in plane plumes. The turbulence measurements have shown that the eddy viscosity and turbulence are significantly higher in the plume compared to an isothermal jet. Detailed measurements of energy balance suggest that buoyant production contributes substantially to this increase.

2018 ◽  
Vol 6 (3) ◽  
pp. 1-12
Author(s):  
Kamil Abdul Hussien

Abstract-The present work investigates the enhancement of heat transfer by using different number of circular fins (8, 10, 12, 16, and 20) in double tube counter flow heat exchanger experimentally. The fins are made of copper with dimensions 66 mm OD, 22 mm ID and 1 mm thickness. Each fin has three of 14 mm diameter perforations located at 120o from each to another. The fins are fixed on a straight smooth copper tube of 1 m length, 19.9 mm ID and 22.2 mm OD. The tube is inserted inside the insulated PVC tube of 100 mm ID. The cold water is pumped around the finned copper tube, inside the PVC, at mass flow rates range (0.01019 - 0.0219) kg/s. The Reynold's number of hot water ranges (640 - 1921). The experiment results are obtained using six double tube heat exchanger (1 smooth tube and the other 5 are finned one). The results, illustrated that the heat transfer coefficient proportionally with the number of fin. The results also showed that the enhancement ratio of heat transfer for finned tube is higher than for smooth tube with (9.2, 10.2, 11.1, 12.1 13.1) times for number of fins (8, 10, 12, 16 and 20) respectively.


1975 ◽  
Vol 45 (1) ◽  
pp. 17-21
Author(s):  
J. M. Little ◽  
A. G. R. Sheil ◽  
J. Loewenthal ◽  
J. May ◽  
A. H. Goodman
Keyword(s):  

2017 ◽  
Vol 6 (2) ◽  
pp. 82
Author(s):  
Sean X. Liu ◽  
Diejun Chen ◽  
George E. Inglett ◽  
Jingyuan Xu

Amaranth-oat composites were developed using gluten free amaranth flour containing essential amino acids and minerals with oat products containing β-glucan, known for lowering blood cholesterol. Amaranth flour and oat bran concentrate (OBC) composites (1:4) were processed using different technologies, including dry mixing, baking, steaming, cold wet blending, and high speed homogenizing (Polytron PT6000) with cold water or hot water. The results showed that water holding capacities, pasting, and rheological properties were dramatically increased by wet blending, Polytron with cold water, and Polytron with hot water followed by drum drying. The processing procedures created dissimilar physical properties that will enhance the application of ancient grains and oat for functional foods that are suitable for people who are gluten-intolerant. In addition, the dietary fiber contents of composites were increased by the incorporation of OBC. The composites can be inexpensively prepared and processed. The new healthful products will be affordable for people who suffer from celiac disease or gluten-intolerant. These innovative gluten-free functional food products will help millions of gluten sensitive consumers enjoy heart-healthy functional foods.


Author(s):  
P. Gaetani ◽  
G. Persico ◽  
V. Dossena ◽  
C. Osnaghi

An extensive experimental analysis was carried out at Politecnico di Milano on the subject of unsteady flow in high pressure (HP) turbine stages. In this paper the unsteady flow measured downstream of a modern HP turbine stage is discussed. Traverses in two planes downstream of the rotor are considered and, in one of them, the effects of two very different axial gaps are investigated: the maximum axial gap, equal to one stator axial chord, is chosen to “switch off” the rotor inlet unsteadiness, while the nominal gap, equal to 1/3 of the stator axial chord, is representative of actual engines. The experiments were performed by means of a fast-response pressure probe, allowing for two-dimensional phase-resolved flow measurements in a bandwidth of 80 kHz. The main properties of the probe and the data processing are described. The core of the paper is the analysis of the unsteady rotor aerodynamics; for this purpose, instantaneous snapshots of the rotor flow in the relative frame are used. The rotor mean flow and its interaction with the stator wakes and vortices are also described. In the outer part of the channel only the rotor cascade effects can be observed, with a dominant role played by the tip-leakage flow and by the rotor tip passage vortex. In the hub region, where the secondary flows downstream of the stator are stronger, the persistence of stator vortices is slightly visible in the maximum stator-rotor axial gap configuration, while in the minimum stator-rotor axial gap configuration the interaction with the rotor vortices dominates the flow field. A fair agreement with the wakes and vortices transport models has been achieved. A discussion of the interaction process is reported giving particular emphasis to the effects of the different cascade axial gaps. Some final considerations on the effects of the different axial gap over the stage performances are reported.


2018 ◽  
Vol 141 (5) ◽  
Author(s):  
Raf Theunissen ◽  
Robert Worboys

Porous disks are commonly encountered in experimental studies dealing with flow through objects such as wind turbines, parachutes, and fluidic devices to regulate pressure and/or downstream turbulence. Perforations are typically staggered and only porosity is altered to attain the required disk drag coefficient, despite a documented influence of topology. Few works have reported, however, to which extent the spatial distribution of the circular perforations affect the mean flow pertaining freestanding disks, and for this reason, this work presents a first, more systematic study focused on the effect of azimuthally varying hole topology and porosity on disk drag and near-wake characteristics. An experimental study performed in airflows of negligible freestream turbulence at Reynolds numbers in the order of 105 is reported and related to the existing literature to ensure reliability. Complementary to drag measurements, near-wake surveys have been performed on a variety of perforation layouts using two-component laser Doppler velocimetry and two-component particle image velocimetry. It is shown that minor changes in perforations can cause drastic changes in near-wake flow topology and no perforation layout can be consistently associated with highest drag. Explicit empirical expressions for drag coefficient linked with the simplified topologies considered have been derived.


1988 ◽  
Vol 1 (21) ◽  
pp. 33 ◽  
Author(s):  
Akio Okayasu ◽  
Tomoya Shibayama ◽  
Kiyoshi Horikawa

In order to establish a model of the vertical distribution of the undertow, laboratory experiments were performed on uniform slopes of 1/20 and 1/30. The turbulent velocity in the surf zone including the area close to the bottom was measured by using a two-component laser doppler velocimeter. The distributions of the mean Reynolds stress and the mean eddy viscosity coefficient were calculated. Based on the experimental results, a model to predict the vertical profile of the undertow was presented.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


Author(s):  
N. F. Timerbaev ◽  
A. K. Ali ◽  
Omar Abdulhadi Mustafa Almohamed ◽  
A. R. Koryakin

In this article, a mathematical simulation of a double pipe heat exchanger is carried out, having the longitudinal rectangular fins with the dimension of (2*3*1000) mm, mounted on the outer surface of the inner tube of the heat exchanger. In this paper, the advantage of using of that type of fins and its effect on the effectiveness of the heat exchanger are studied with the help of the computer program. The carried out research allowsmaking the calculation to find the optimum design parameters of heat exchangers. The outer tube diameter is (34.1mm) while the inner tube diameter is (16.05mm). The tubes wall thickness is (1.5mm) and the model length was (1 m). The hot water is flowing through the inner tube in parallel with the cold water that passing the outer tube. The hot and cold water temperature at the inlet is (75°C & 30°C) respectively. The mass flow rate inside the central pipe is (0.1 kg/s) while the annular pipe carrying (0.3 kg/s). In the present work, the program ANSYS Workbench 15.0 was used to find out the results of heat transfer as well as the behavior of liquids inside the heat exchangers.


2010 ◽  
Vol 7 (3) ◽  
pp. 1159-1165
Author(s):  
Baghdad Science Journal

The antimicrobial activity of ginger extracts ( cold-water, hot-water, ethanolic and essential oil ) against some of pathogenic bacteria ( Escherichia coli , Salmonella sp , Klebsiella sp , Serratia marcescens, Vibrio cholerae , Staphylococcus aureus , Streptococcus sp) was investigated using Disc diffusion method , and the results were compared with the antimicrobial activity of 12 antibiotics on the same bacteria . The results showed that the ginger extracts were more effective on gram-positive bacteria than gram-negative . V. cholerae and S. marcescens,were the most resistant bacteria to the extracts used , while highest inhibition was noticed against Streptococcus sp (28 mm) . The ethanolic extract showed the broadest antibacterial activity ( 11 to 28 mm ) , in comparison with moderate activity of essential oil , it was observed that the cold-water extract was more effective on the bacteria than hot-water extract . Ginger ethanolic extract presented higher diameter of inhibition zone for Streptococcus sp than in Ciprofloxacin , Cefotaxime , Cefalotin , Cephalexin and Cephaloridine , also it was found a similarity between the higher inhibition zones of ethanolic extract of ginger and some antibiotics for S. aureus , E. coli , Salmonella sp and Klebsiella sp . V. cholerae and S. marcescens,also highly resistant to antibiotics . Phytochemical analysis of ethanolic extract of ginger revealed the present of glycosides, terpenoids, flavonids and phenolic compounds


Sign in / Sign up

Export Citation Format

Share Document