An Omnidirectional Wall Shear Meter

1980 ◽  
Vol 102 (1) ◽  
pp. 21-25 ◽  
Author(s):  
M. H. Tennant ◽  
F. J. Pierce ◽  
J. E. McAllister

An omnidirectional wall shear meter has been developed which is capable of the direct measurement of both magnitude and direction of wall shear stress. Linearity, resolution, and accuracy have been demonstrated analytically and experimentally by static and dynamic calibration. The floating element device works on the cantilevered beam principle. Eddy current probes, set at right angles to the beam and to each other, sense the magnitude and direction of deflection which can be calibrated against known force loadings. The device is used to measure wall shear stress in three-dimensional flows, and was specifically developed as a means of validating proposed three-dimensional near-wall similarity laws.

Circulation ◽  
2014 ◽  
Vol 129 (6) ◽  
pp. 673-682 ◽  
Author(s):  
Riti Mahadevia ◽  
Alex J. Barker ◽  
Susanne Schnell ◽  
Pegah Entezari ◽  
Preeti Kansal ◽  
...  

Author(s):  
Leonie Rouleau ◽  
Joanna Rossi ◽  
Jean-Claude Tardif ◽  
Rosaire Mongrain ◽  
Richard L. Leask

Endothelial cells (ECs) are believed to respond differentially to hemodynamic forces in the vascular tree. Once atherosclerotic plaque has formed in a vessel, the obstruction creates complex spatial gradients in wall shear stress (WSS). In vitro models have used mostly unrealistic and simplified geometries, which cannot reproduce accurately physiological conditions. The objective of this study was to expose ECs to the complex WSS pattern created by an asymmetric stenosis. Endothelial cells were grown and exposed for different times to physiological steady flows in straight dynamic controls and in idealized asymmetric stenosis models. Cell morphology was noticeably different in the regions with spatial WSS gradients, being more randomly oriented and of cobblestone shape. Inflammatory molecule expression was also altered by exposure to shear and endothelial nitric oxide synthase (eNOS) was upregulated by its presence. A regional response in terms of inflammation was observed through confocal microscopy. This work provides a more realistic model to study endothelial cell response to spatial and temporal WSS gradients that are present in vivo and is an important advancement towards a better understanding of the mechanisms involved in coronary artery disease.


2019 ◽  
Vol 31 (12) ◽  
pp. 121903 ◽  
Author(s):  
Christopher Cox ◽  
Mohammad Reza Najjari ◽  
Michael W. Plesniak

2009 ◽  
Vol 7 (42) ◽  
pp. 91-103 ◽  
Author(s):  
C. Poelma ◽  
K. Van der Heiden ◽  
B. P. Hierck ◽  
R. E. Poelmann ◽  
J. Westerweel

In order to study the role of blood–tissue interaction in the developing chicken embryo heart, detailed information about the haemodynamic forces is needed. In this study, we present the first in vivo measurements of the three-dimensional distribution of wall shear stress (WSS) in the outflow tract (OFT) of an embryonic chicken heart. The data are obtained in a two-step process: first, the three-dimensional flow fields are measured during the cardiac cycle using scanning microscopic particle image velocimetry; second, the location of the wall and the WSS are determined by post-processing flow velocity data (finding velocity gradients at locations where the flow approaches zero). The results are a three-dimensional reconstruction of the geometry, with a spatial resolution of 15–20 µm, and provides detailed information about the WSS in the OFT. The most significant error is the location of the wall, which results in an estimate of the uncertainty in the WSS values of 20 per cent.


1982 ◽  
Vol 104 (2) ◽  
pp. 150-155 ◽  
Author(s):  
J. E. McAllister ◽  
F. J. Pierce ◽  
M. H. Tennant

Unique, simultaneous direct measurements of the magnitude and direction of the local wall shear stress in a pressure-driven three-dimensional turbulent boundary layer are presented. The flow is also described with an oil streak wall flow pattern, a map of the wall shear stress-wall pressure gradient orientations, a comparison of the wall shear stress directions relative to the directions of the nearest wall velocity as measured with a typical, small boundary layer directionally sensitive claw probe, as well as limiting wall streamline directions from the oil streak patterns, and a comparison of the freestream streamlines and the wall flow streamlines. A review of corrections for direct force sensing shear meters for two-dimensional flows is presented with a brief discussion of their applicability to three-dimensional devices.


Author(s):  
O. N. Kashinsky ◽  
P. D. Lobanov ◽  
A. S. Kurdyumov ◽  
N. A. Pribaturin

Experimental study of gas-liquid two-phase flow in an annular channel is performed. The channel consisted of two coaxial tubes with the diameters of 42 and 20 mm. An obstacle covering a quarter of the channel section was placed in the channel to produce a strong three-dimensional disturbance of the flow. Gas-liquid flow was produced by injecting air bubbles at the channel entrance through a special mixer. Measurements of local wall shear stress are performed using an electrochemical technique. Measurements of time-averaged and fluctuational wall shear stress are performed at various points relative to the obstacle, this allowed to study the field of the hydrodynamic parameters of the flow. Local void fraction is measured using a conductivity probe which traversed across the channel. The distribution of local void fraction in the region downstream the obstacle is obtained. Increased values of local void fraction in the region close to the obstacle are detected. The experimental data obtained can be used for validation of existing and developing computer codes accounting for a 3-D structure of two-phase flows.


2005 ◽  
Vol 128 (3) ◽  
pp. 347-359 ◽  
Author(s):  
Divakar Rajamohan ◽  
Rupak K. Banerjee ◽  
Lloyd H. Back ◽  
Ashraf A. Ibrahim ◽  
Milind A. Jog

A major consequence of stent implantation is restenosis that occurs due to neointimal formation. This patho-physiologic process of tissue growth may not be completely eliminated. Recent evidence suggests that there are several factors such as geometry and size of vessel, and stent design that alter hemodynamic parameters, including local wall shear stress distributions, all of which influence the restenosis process. The present three-dimensional analysis of developing pulsatile flow in a deployed coronary stent quantifies hemodynamic parameters and illustrates the changes in local wall shear stress distributions and their impact on restenosis. The present model evaluates the effect of entrance flow, where the stent is placed at the entrance region of a branched coronary artery. Stent geometry showed a complex three-dimensional variation of wall shear stress distributions within the stented region. Higher order of magnitude of wall shear stress of 530dyn∕cm2 is observed on the surface of cross-link intersections at the entrance of the stent. A low positive wall shear stress of 10dyn∕cm2 and a negative wall shear stress of −10dyn∕cm2 are seen at the immediate upstream and downstream regions of strut intersections, respectively. Modified oscillatory shear index is calculated which showed persistent recirculation at the downstream region of each strut intersection. The portions of the vessel where there is low and negative wall shear stress may represent locations of thrombus formation and platelet accumulation. The present results indicate that the immediate downstream regions of strut intersections are areas highly susceptible to restenosis, whereas a high shear stress at the strut intersection may cause platelet activation and free emboli formation.


Sign in / Sign up

Export Citation Format

Share Document