Experimental Study of PCM Inclusion in Different Building Envelopes

2009 ◽  
Vol 131 (4) ◽  
Author(s):  
C. Castellón ◽  
A. Castell ◽  
M. Medrano ◽  
I. Martorell ◽  
L. F. Cabeza

The main objective of this paper is to demonstrate experimentally that it is possible to improve the thermal comfort and reduce the energy consumption of a building without substantial increase in the weight of the construction materials with the inclusion of phase change materials (PCM). PCM are a suitable and promising technology for this application. This paper presents an experimental setup to test PCM with various typical insulation and construction materials in real conditions in Puigverd de Lleida (Lleida, Spain). Nine small house-sized cubicles were constructed: two with concrete, five with conventional brick, and two with alveolar brick. PCM was added in one cubicle of each typology. For each type of construction specific experiments were done. In all cubicles, free-floating temperature experiments were performed to determine the benefits of using PCM. A Trombe wall was added in both concrete cubicles and its influence was investigated. All brick cubicles were equipped with domestic heat pumps as Heating, Ventilation, and Air Conditioning (HVAC) system; therefore, the energy consumption was registered, providing real information about the energy savings. Results were very good for the concrete cubicles, since temperature oscillation were reduced by up to 4°C through the use of PCM and also peak temperatures in the PCM cubicle were shifted in later hours. In the brick cubicles, the energy consumption of the HVAC system in summer was reduced by using PCM for set points higher than 20°C. During winter an insulation effect of the PCM is observed, keeping the temperatures of the cubicles warmer, especially during the cold hours of the day.

2012 ◽  
Vol 9 (2) ◽  
pp. 65
Author(s):  
Alhassan Salami Tijani ◽  
Nazri Mohammed ◽  
Werner Witt

Industrial heat pumps are heat-recovery systems that allow the temperature ofwaste-heat stream to be increased to a higher, more efficient temperature. Consequently, heat pumps can improve energy efficiency in industrial processes as well as energy savings when conventional passive-heat recovery is not possible. In this paper, possible ways of saving energy in the chemical industry are considered, the objective is to reduce the primary energy (such as coal) consumption of power plant. Particularly the thermodynamic analyses ofintegrating backpressure turbine ofa power plant with distillation units have been considered. Some practical examples such as conventional distillation unit and heat pump are used as a means of reducing primary energy consumption with tangible indications of energy savings. The heat pump distillation is operated via electrical power from the power plant. The exergy efficiency ofthe primary fuel is calculated for different operating range ofthe heat pump distillation. This is then compared with a conventional distillation unit that depends on saturated steam from a power plant as the source of energy. The results obtained show that heat pump distillation is an economic way to save energy if the temperaturedifference between the overhead and the bottom is small. Based on the result, the energy saved by the application of a heat pump distillation is improved compared to conventional distillation unit.


2012 ◽  
Vol 9 (2) ◽  
pp. 65
Author(s):  
Alhassan Salami Tijani ◽  
Nazri Mohammed ◽  
Werner Witt

Industrial heat pumps are heat-recovery systems that allow the temperature of waste-heat stream to be increased to a higher, more efficient temperature. Consequently, heat pumps can improve energy efficiency in industrial processes as well as energy savings when conventional passive-heat recovery is not possible. In this paper, possible ways of saving energy in the chemical industry are considered, the objective is to reduce the primary energy (such as coal) consumption of power plant. Particularly the thermodynamic analyses of integrating backpressure turbine of a power plant with distillation units have been considered. Some practical examples such as conventional distillation unit and heat pump are used as a means of reducing primary energy consumption with tangible indications of energy savings. The heat pump distillation is operated via electrical power from the power plant. The exergy efficiency of the primary fuel is calculated for different operating range of the heat pump distillation. This is then compared with a conventional distillation unit that depends on saturated steam from a power plant as the source of energy. The results obtained show that heat pump distillation is an economic way to save energy if the temperature difference between the overhead and the bottom is small. Based on the result, the energy saved by the application of a heat pump distillation is improved compared to conventional distillation unit. 


Author(s):  
Eray Mertkan Meric ◽  
Savas Erdem ◽  
Ezgi Gurbuz

There has been a continuous increase in world population and industrialization. In parallel, energy consumption grew substantially in the world. The residential buildings constitute the majority of the total consumption in the developed world. Therefore, energy saving and reducing heat losses of buildings are of major concern for our society. At this point, phase changing materials (PCMs) show up as one of the most useful materials in building design. In this study, PCMs, which are used at places such as facade of buildings, bricks, and inside of concrete in order to be able to reduce the energy consumption due to heating and cooling, to provide comfort temperature inside buildings, are extensively reviewed.


2020 ◽  
Vol 12 (6) ◽  
pp. 2573
Author(s):  
Maatouk Khoukhi ◽  
Abeer Fuad Darsaleh ◽  
Sara Ali

Retrofitting an existing building can oftentimes be more cost-effective than building a new facility. Since buildings consume a significant amount of energy, particularly for heating and cooling, and because existing buildings comprise the largest segment of the built environment, it is important to initiate energy conservation retrofits to reduce energy consumption and the cost of heating, cooling, and lighting buildings. However, conserving energy is not the only reason for retrofitting existing buildings. The goal should be to create a high-performance building by applying an integrated, whole-building design process to the project during the planning phase that ensures that all key design objectives are met. This paper presents a real case study of the retrofitting of an existing building to achieve lower energy consumption. Indeed, most of the constructed buildings in the UAE are unsuitable for the region, which is characterized by a very harsh climate that causes massive cooling loads and energy consumption due to an appropriate selection of design parameters at the design level. In this study, a monthly computer simulation of energy consumption of an office building in Sharjah was carried out under UAE weather conditions. Several parameters, including the building orientation, heating, ventilation, and air conditioning (HVAC) system, external shading, window-to-wall ratio, and the U-values of the walls and the roof, were investigated and optimized to achieve lower energy consumption. The simulation shows that the best case is 41.7% more efficient than the real (original) case and 30.6% more than the base case. The most sensitive parameter in the retrofitting alternatives is the roof component, which affects the energy savings by 8.49%, followed by the AC system with 8.34% energy savings if well selected using the base case. Among the selected five components, a new roof structure contributed the most to the decrease in the overall energy consumption (approximately 38%). This is followed by a new HVAC system, which leads to a 37% decrease, followed by a new wall type with insulation, resulting in a 20% decrease.


2021 ◽  
Author(s):  
Lindsay Fialkov

This major research project focuses on reducing the energy consumption, by modelling a radiant floor heating system with phase change materials, in the Toronto climate. Computer generated simulations were performed using DesignBuilder software, using an example of a typical condominium in Toronto .Two south facing suites and two north facing suites were investigated. Of those suites, one north facing suite had PCM below the finished floor, as well as one south facing suite. The objective of these simulations was to determine the impact of using PCM in the condo suites. Three different types of PCM were used, in order to determine which type had the biggest energy savings. The PCMs were M91/Q21, M51/Q21 and M27/Q21. The final results showed that the suites with the M27/Q21 PCM had the lowest energy usage. A cost savings comparison was performed based on the rate of energy used and the cost of the energy, provided by the Ontario Energy Board.


2021 ◽  
Vol 13 (23) ◽  
pp. 12936
Author(s):  
Muriel Iten

A latent energy storage (LES) unit is presented in this paper for free space cooling and ventilation application. The unit includes multiple phase change materials (PCM) to advance the thermal performance of common LES units. It is composed by metallic rectangular panels containing commercial paraffins with melting temperatures ranging among 20 °C and 25 °C and surrounded by air channels. The average cooling load of the unit corresponds to approximately 1 kW over 8 h. It fulfils the peak ventilation cooling load during summer of an office building in Portugal. The study provides a techno-economic analysis and the environmental benefits of the LES technology compared to a traditional air conditioning (AC) unit for the cooling and ventilation of an office building. During daytime, the air-multiple PCM unit allows reducing the energy consumption by nearly 200 kWh. The full charging of the PMs during nighttime, requires significant energy consumption due to the high air flowrate demand for full solidification. The competitiveness of such units can be achieved by introducing fins into the panels, allowing double the energy savings. In an overall perspective, the unit presents several benefits such as lower initial cost and reduced maintenance requirements (non-use of refrigerants and batteries) that also allows better personal health issues when related to traditional ACs.


Energies ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 6198
Author(s):  
Joachim Baumeister ◽  
Jörg Weise ◽  
Sebastian Myslicki ◽  
Esther Kieseritzky ◽  
Götz Lindenberg

Thermal comfort (heating, ventilation and air conditioning, HVAC) and the energy consumption involved with it can put a strain on the driving range of fully electric vehicles (FEV), especially in certain times of the year as midsummer or winter. In order to reduce the energy consumption of HVAC, improved thermal management and adapted means of energy storage are needed. One part of the solution can be the use of phase change materials (PCM) for storing waste heat. For the specific application, however, a high loading/unloading power rate is required, which is challenging as the PCMs exhibit low heat conductivities. In the presented work, a storage demonstrator system was investigated which is part of an HVAC system of a specific fully electric vehicle. The profile of requirements of the system (power, stored capacity and allowed volume) make a new design of the storage necessary. Two demonstrator units, in which the PCM was combined with aluminum foam, were manufactured and their power output in dependency on the fluid flow of the coolant system was compared. An adapted squeeze casting process with polymer placeholders was used for the production of the aluminium foam. This process results in foams with a specific pore structure and allows the in-situ integration of the heat transfer fluid (HTF) pipes. Both newly developed PCM storage systems satisfy the HVAC system requirements.


Energies ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5541
Author(s):  
Alessandro Franco ◽  
Lorenzo Miserocchi ◽  
Daniele Testi

The paper analyzes and compares the perspectives for reducing the energy consumption associated to the operation of Heating Ventilation and Air Conditioning system for climatic control of large-size non-residential buildings. Three different control strategies are considered comparing the use of boiler and heat pumps as heating systems and analyzing the use of demand-controlled ventilation, operating on the effective occupancy of the building. The control strategies are applied to two different educational buildings with shapes representative of typical educational structures. The results of the analysis show how the energy consumption can be reduced up to 70%, shifting from the actual values of the energy intensity of over 300 kWh/m2 for year to values of less than 100 kWh/m2 per year. The significance of the energy savings achieved in such different buildings has led to the identification of a possible benchmark for HVAC systems in the next future years which could help reach the environmental targets in this sector.


2021 ◽  
Author(s):  
Lindsay Fialkov

This major research project focuses on reducing the energy consumption, by modelling a radiant floor heating system with phase change materials, in the Toronto climate. Computer generated simulations were performed using DesignBuilder software, using an example of a typical condominium in Toronto .Two south facing suites and two north facing suites were investigated. Of those suites, one north facing suite had PCM below the finished floor, as well as one south facing suite. The objective of these simulations was to determine the impact of using PCM in the condo suites. Three different types of PCM were used, in order to determine which type had the biggest energy savings. The PCMs were M91/Q21, M51/Q21 and M27/Q21. The final results showed that the suites with the M27/Q21 PCM had the lowest energy usage. A cost savings comparison was performed based on the rate of energy used and the cost of the energy, provided by the Ontario Energy Board.


2021 ◽  
Vol 286 ◽  
pp. 01012
Author(s):  
Jamal Al Douri ◽  
Kamel S. Hmood ◽  
Valentin Apostol ◽  
Horatiu Pop ◽  
Saleh J. Alqaisy ◽  
...  

The paper presents a literature review regarding defrosting methods for household refrigeration and heat pumps. The literature review covers the period between 2008 and 2020. A number of 61 papers have been studied. The literature review was conducted by dividing the defrost methods into passive and active. Passive methods involve surface coating and off-cycle. The active defrost methods involve reverse cycle, ultrasonic vibration, hot–gas defrost, electric heating and hot fluid. Surface coating and ultrasonic vibration are recent defrost methods proposed in the literature. Also, recently, phase change materials have been used in household refrigerators to improve their efficiency. This is a topic that needs further investigation and is a subject of interest as it can lead to lower energy consumption during defrost cycles. From the present study, the research direction regarding the use of PCMs in defrost cycles can be highlighted.