A Finite-Element Model of Blood Flow in Arteries Including Taper, Branches, and Obstructions

1986 ◽  
Vol 108 (2) ◽  
pp. 161-167 ◽  
Author(s):  
G. Porenta ◽  
D. F. Young ◽  
T. R. Rogge

A nonlinear mathematical model of arterial blood flow, which can account for tapering, branching, and the presence of stenosed segments, is presented. With the finite-element method, the model equations are transformed into a system of algebraic equations that can be solved on a high-speed digital computer to yield values of pressure and volume rate of flow as functions of time and arterial position. A model of the human femoral artery is used to compare the effects of linear and nonlinear modeling. During periods of rapid alterations in pressure or flow, the nonlinear model shows significantly different results than the linear model. The effect of a stenosis on pressure and flow waveforms is also simulated, and the results indicate that these waveforms are significantly altered by moderate and severe stenoses.

Sensors ◽  
2020 ◽  
Vol 20 (16) ◽  
pp. 4547
Author(s):  
Yanjun Liu ◽  
Guoqiang Liu ◽  
Dan Yang ◽  
Bin Xu

Background and Objectives: Cardiovascular and cerebrovascular diseases caused by arterial stenosis and sclerosis are the main causes of human death. Although there are mature diagnostic techniques in clinical practice, they are not suitable for early disease prediction and monitoring due to their high cost and complex operation. The purpose of this paper is to study the coupling effect of arterial blood flow and linear gradient magnetic field, and to propose a method for the reconstruction of the arterial profile, which will lay a theoretical foundation for new electromagnetic artery scanning imaging technology. Methods and Models: A combination coil composed of gradient coils and drive coils is applied as a magnetic field excitation source. By controlling the excitation current, a linearly gradient magnetic field with a line-shaped zero magnetic field is generated, and the zero magnetic field is driven to scan in a specific direction. According to the magnetoelectric effect of blood flow, under the action of the external magnetic field, the voltage signals on the body surface can be detected by measuring electrodes. The location of the artery center line can be determined by the time–space relationship between voltage signals and zero magnetic field scanning. In addition, based on the reciprocity theorem integral equation, a numerical model between the amplitude of the voltage signal and the arterial radius is derived to reconstruct the arterial radius. The above physical process was simulated in the finite element analysis software COMSOL, and the voltage signals obtained from the simulation verified the arterial profile reconstruction. Results: Through finite element simulation verification, the imaging method based on a linear gradient magnetic field has a numerical accuracy of 90% and a spatial resolution of 1 mm. Moreover, under 100 Hz low-frequency alternating current excitation, the single scanning time is 0.005 s, which is far shorter than the arterial blood flow change cycle, meeting the requirements of real-time imaging. The results demonstrate the effectiveness and high theoretical feasibility of the proposed method in real-time arterial imaging. Conclusions: This study indicates the potential application of linear gradient magnetic fields in arterial profile imaging. Compared with traditional electromagnetic imaging methods, the proposed method has the advantages of fast imaging speed and high resolution, showing the certain application value in early real-time imaging of arterial disease. However, further studies are necessary to confirm its effectiveness in clinical practice by more medical data and real cases.


Author(s):  
M. H. A. van Geel ◽  
C. G. Giannopapa ◽  
B. J. van der Linden

In cardiovascular research, FSI is expressed by the interaction of the blood with the vessel or the heart. FSI plays a crucial role when the deformation of the boundary, in this case the vessel wall, cannot be neglected. Arterial blood flow and wave propagation in liquid filled vessels has been investigated by many researchers. Their work comprises computational, theoretical and experimental investigations and will be outlined below. This paper presents the development and validation of an arterial blood flow model. The model has been developed using finite elements and the fluid and the solid are coupled using the ALE method. This method allows moving boundaries without the need for the mesh movement to follow the material. In this paper both straight and tapered aortic analogues are included in the investigation. The pressure, pressure gradient, fluid flow and wall distension obtained from the finite element model is compared with an unique experimental data set and analytical theory. There is a good agreement between the computational, analytical and experimental results.


2013 ◽  
Vol 23 (2) ◽  
Author(s):  
Xenia Descovich ◽  
Giuseppe Pontrelli ◽  
Sauro Succi ◽  
Simone Melchionna ◽  
Manfred Bammer

Children ◽  
2021 ◽  
Vol 8 (5) ◽  
pp. 353
Author(s):  
Jayasree Nair ◽  
Lauren Davidson ◽  
Sylvia Gugino ◽  
Carmon Koenigsknecht ◽  
Justin Helman ◽  
...  

The optimal timing of cord clamping in asphyxia is not known. Our aims were to determine the effect of ventilation (sustained inflation–SI vs. positive pressure ventilation–V) with early (ECC) or delayed cord clamping (DCC) in asphyxiated near-term lambs. We hypothesized that SI with DCC improves gas exchange and hemodynamics in near-term lambs with asphyxial bradycardia. A total of 28 lambs were asphyxiated to a mean blood pressure of 22 mmHg. Lambs were randomized based on the timing of cord clamping (ECC—immediate, DCC—60 s) and mode of initial ventilation into five groups: ECC + V, ECC + SI, DCC, DCC + V and DCC + SI. The magnitude of placental transfusion was assessed using biotinylated RBC. Though an asphyxial bradycardia model, 2–3 lambs in each group were arrested. There was no difference in primary outcomes, the time to reach baseline carotid blood flow (CBF), HR ≥ 100 bpm or MBP ≥ 40 mmHg. SI reduced pulmonary (PBF) and umbilical venous (UV) blood flow without affecting CBF or umbilical arterial blood flow. A significant reduction in PBF with SI persisted for a few minutes after birth. In our model of perinatal asphyxia, an initial SI breath increased airway pressure, and reduced PBF and UV return with an intact cord. Further clinical studies evaluating the timing of cord clamping and ventilation strategy in asphyxiated infants are warranted.


2015 ◽  
Vol 26 (8) ◽  
pp. 2779-2789 ◽  
Author(s):  
Claus Christian Pieper ◽  
Winfried A. Willinek ◽  
Daniel Thomas ◽  
Hojjat Ahmadzadehfar ◽  
Markus Essler ◽  
...  