Hot-Film Wall Shear Probe Measurements Inside a Ventricular Assist Device

1988 ◽  
Vol 110 (4) ◽  
pp. 326-333 ◽  
Author(s):  
J. T. Baldwin ◽  
J. M. Tarbell ◽  
S. Deutsch ◽  
D. B. Geselowitz ◽  
G. Rosenberg

Wall shear rates at eleven sites within the Penn State Electric Ventricular Assist Device (EVAD) were determined with the pump operating under conditions of 30 and 50 percent systolic duration and a mean flow rate of 5.8 L/min using a flush-mounted hot-film probe. Probe calibrations were performed with the hot-film in two orientations relative to the flow direction: a standard orientation and an orientation in which the hot-film was rotated by 90 deg from the standard orientation. The magnitude and direction of the wall shear stress at each site within the EVAD were estimated from ensemble averaged voltage data recorded for similar standard and rotated film orientations. The results indicate that, during diastole the wall shear stress direction around the pump’s periphery for both operating conditions is predominantly perpendicular to the inflow-outflow plane (in the direction of the pusher plate motion) and reaches a peak value of approximately 350 dynes/cm2. The highest wall shear stresses were found near the prosthetic aortic valve (inside the EVAD) under the 30 percent systolic duration condition and are estimated to be as high as 2700 dynes/cm2. Peak shear stress values of 1400 dynes/cm2 were observed in the vicinity of the prosthetic mitral valve under both operating conditions. The results suggested that the valve regions are substantially more hemolytic than other wall regions of the EVAD; the magnitudes of the wall shear stresses are sensitive to operating conditions; and that wall shear in the direction of pusher plate motion can be significant.

1988 ◽  
Vol 16 (2) ◽  
pp. 235-238
Author(s):  
Subhashis Nandy ◽  
Alex Yefim Bekker ◽  
Gregory Allen Winchell ◽  
John Francis O'Riordan

1994 ◽  
Vol 116 (3) ◽  
pp. 645-649 ◽  
Author(s):  
Josef Daniel Ackerman ◽  
Louis Wong ◽  
C. Ross Ethier ◽  
D. Grant Allen ◽  
Jan K. Spelt

We present a Preston tube device that combines both total and static pressure readings for the measurement of wall shear stress. As such, the device facilitates the measurement of wall shear stress under conditions where there is streamline curvature and/or over surfaces on which it is difficult to either manufacture an array of static-pressure taps or to position a single tap. Our “Preston-static” device is easily and conveniently constructed from commercially available regular and side-bored syringe needles. The pressure difference between the total pressure measured in the regular syringe needle and the static pressure measured in the side-bored one is used to determine the wall shear stress. Wall shear stresses measured in pipe flow were consistent with independently determined values and values obtained using a conventional Preston tube. These results indicate that Preston-static tubes provide a reliable and convenient method of measuring wall shear stress.


2021 ◽  
Vol 12 ◽  
Author(s):  
Yu Wang ◽  
Junwei Wang ◽  
Jing Peng ◽  
Mingming Huo ◽  
Zhiqiang Yang ◽  
...  

Patients with heart failure (HF) or undergoing cardiogenic shock and percutaneous coronary intervention require short-term cardiac support. Short-term cardiac support using a left ventricular assist device (LVAD) alters the pressure and flows of the vasculature by enhancing perfusion and improving the hemodynamic performance for the HF patients. However, due to the position of the inflow and outflow of the LVAD, the local hemodynamics within the aorta is altered with the LVAD support. Specifically, blood velocity, wall shear stress, and pressure difference are altered within the aorta. In this study, computational fluid dynamics (CFD) was used to elucidate the effects of a short-term LVAD for hemodynamic performance in a patient-specific aorta model. The three-dimensional (3D) geometric models of a patient-specific aorta and a short-term LVAD, Impella CP, were created. Velocity, wall shear stress, and pressure difference in the patient-specific aorta model with the Impella CP assistance were calculated and compared with the baseline values of the aorta without Impella CP support. Impella CP support augmented cardiac output, blood velocity, wall shear stress, and pressure difference in the aorta. The proposed CFD study could analyze the quantitative changes in the important hemodynamic parameters while considering the effects of Impella CP, and provide a scientific basis for further predicting and assessing the effects of these hemodynamic signals on the aorta.


2000 ◽  
Vol 123 (2) ◽  
pp. 134-144 ◽  
Author(s):  
Sujata Prakash ◽  
C. Ross Ethier

Computational techniques are widely used for studying large artery hemodynamics. Current trends favor analyzing flow in more anatomically realistic arteries. A significant obstacle to such analyses is generation of computational meshes that accurately resolve both the complex geometry and the physiologically relevant flow features. Here we examine, for a single arterial geometry, how velocity and wall shear stress patterns depend on mesh characteristics. A well-validated Navier-Stokes solver was used to simulate flow in an anatomically realistic human right coronary artery (RCA) using unstructured high-order tetrahedral finite element meshes. Velocities, wall shear stresses (WSS), and wall shear stress gradients were computed on a conventional “high-resolution” mesh series (60,000 to 160,000 velocity nodes) generated with a commercial meshing package. Similar calculations were then performed in a series of meshes generated through an adaptive mesh refinement (AMR) methodology. Mesh-independent velocity fields were not very difficult to obtain for both the conventional and adaptive mesh series. However, wall shear stress fields, and, in particular, wall shear stress gradient fields, were much more difficult to accurately resolve. The conventional (nonadaptive) mesh series did not show a consistent trend towards mesh-independence of WSS results. For the adaptive series, it required approximately 190,000 velocity nodes to reach an r.m.s. error in normalized WSS of less than 10 percent. Achieving mesh-independence in computed WSS fields requires a surprisingly large number of nodes, and is best approached through a systematic solution-adaptive mesh refinement technique. Calculations of WSS, and particularly WSS gradients, show appreciable errors even on meshes that appear to produce mesh-independent velocity fields.


2018 ◽  
Vol 152 ◽  
pp. 02004 ◽  
Author(s):  
Jacky Ling ◽  
Felicia Wong Yen Myan

Biofouling is the accumulation of unwanted material on surfaces submerged or semi submerged over an extended period. This study investigates the antifouling performance of a new bioinspired topography design. A shark riblets inspired topography was designed with Solidworks and CFD simulations were antifouling performance. The study focuses on the fluid flow velocity, the wall shear stress and the appearance of vortices are to be noted to determine the possible locations biofouling would most probably occur. The inlet mass flow rate is 0.01 kgs-1 and a no-slip boundary condition was applied to the walls of the fluid domain. Simulations indicate that Velocity around the topography averaged at 7.213 x 10-3 ms-1. However, vortices were observed between the gaps. High wall shear stress is observed at the peak of each topography. In contrast, wall shear stress is significantly low at the bed of the topography. This suggests the potential location for the accumulation of biofouling. Results show that bioinspired antifouling topography can be improved by reducing the frequency of gaps between features. Linear surfaces on the topography should also be minimized. This increases the avenues of flow for the fluid, thus potentially increasing shear stresses with surrounding fluid leading to better antifouling performance.


2018 ◽  
Vol 2018 ◽  
pp. 1-16 ◽  
Author(s):  
Mongkol Kaewbumrung ◽  
Somsak Orankitjaroen ◽  
Pichit Boonkrong ◽  
Buraskorn Nuntadilok ◽  
Benchawan Wiwatanapataphee

A mathematical model of dispersed bioparticle-blood flow through the stenosed coronary artery under the pulsatile boundary conditions is proposed. Blood is assumed to be an incompressible non-Newtonian fluid and its flow is considered as turbulence described by the Reynolds-averaged Navier-Stokes equations. Bioparticles are assumed to be spherical shape with the same density as blood, and their translation and rotational motions are governed by Newtonian equations. Impact of particle movement on the blood velocity, the pressure distribution, and the wall shear stress distribution in three different severity degrees of stenosis including 25%, 50%, and 75% are investigated through the numerical simulation using ANSYS 18.2. Increasing degree of stenosis severity results in higher values of the pressure drop and wall shear stresses. The higher level of bioparticle motion directly varies with the pressure drop and wall shear stress. The area of coronary artery with higher density of bioparticles also presents the higher wall shear stress.


2019 ◽  
Vol 141 (11) ◽  
Author(s):  
Patrick Weidman

The problem of stagnation-point flow impinging radially on a linearly twisting cylinder is considered. This advances previous work on the motion outside a cylinder undergoing linear torsional motion. The problem is governed by a Reynolds number R and a dimensionless torsion rate σ. Numerical calculations are carried out using the ODEINT program, and convergence of the shooting method is obtained using the MNEWT program. The radial and azimuthal wall shear stresses are found over a range of R and σ, and radial and azimuthal velocity profiles at σ={0,1,2} are presented for various values of R. The interesting feature is that the axial wall shear stress parameter f″(1) is a very weak function of σ while the azimuthal wall shear stress parameter g′(1) is a strong function of σ although both stress parameters are a strong function of R.


Sign in / Sign up

Export Citation Format

Share Document