Effects of Camera Switching on Fine Accuracy in a Motion Capture System

2008 ◽  
Vol 131 (1) ◽  
Author(s):  
Laurel Kuxhaus ◽  
Patrick J. Schimoler ◽  
Jeffrey S. Vipperman ◽  
Mark Carl Miller

When using optical motion capture systems, increasing the number of cameras improves the visibility. However, the software used to deal with the information fusion from multiple cameras may compromise the accuracy of the system due to camera dropout, which can vary with time. In cadaver studies of radial head motion, increasing the number of cameras used by the motion capture system seemed to decrease the accuracy of the measurements. This study investigates the cause. The hypothesis was that errors in position can be induced when markers are obscured from and then restored to a camera’s viewable range, as can happen in biomechanical studies. Accuracy studies quantified the capabilities of the motion capture system with precision translation and rotation movements. To illustrate the effect that abrupt perceived changes in a marker’s position can have on the calculation of radial head travel, simulated motion experiments were performed. In these studies, random noise was added to simulated data, which obscured the resultant path of motion. Finally, camera-blocking experiments were performed in which precise movements were measured with a six-camera Vicon system and the errors between the actual and perceived motion were computed. During measurement, cameras were selectively blocked and restored to view. The maximum errors in translation and rotation were 3.7 mm and 0.837 deg, respectively. Repeated measures analysis of variance (ANOVAs) (α=0.05) confirmed that the camera-blocking influenced the results. Taken together, these results indicate that camera-switching can affect the observation of fine movements using a motion analysis system with a large number of cameras. One solution is to offer opportunity for user interaction in the software to choose the cameras used for each instant of time.

2011 ◽  
Vol 08 (02) ◽  
pp. 275-299 ◽  
Author(s):  
JUNG-YUP KIM ◽  
YOUNG-SEOG KIM

This paper, describes the development of a motion capture system with novel features for biped robots. In general, motion capture is effectively utilized in the field of computer animation. In the field of humanoid robotics, the number of studies attempting to design human-like gaits by using expensive optical motion capture systems is increasing. The optical motion capture systems used in these studies have involved a large number of cameras because such systems use small-sized ball markers; hence the position accuracy of the markers and the system calibration are very significant. However, since the human walking gait is a simple periodic motion rather than a complex motion, we have developed a specialized motion capture system for this study using dual video cameras and large band-type markers without high-level system calibration in order to capture the human walking gait. In addition to its lower complexity, the proposed capture method requires only a low-cost system and has high space efficiency. An image processing algorithm is also proposed for deriving the human gait data. Finally, we verify the reliability and accuracy of our system by comparing a zero moment point (ZMP) trajectory calculated by the motion captured data with a ZMP trajectory measured by foot force sensors.


2017 ◽  
Vol 2017 (0) ◽  
pp. A-36
Author(s):  
Tatsuro Ishizuka ◽  
Tokio Maeda ◽  
Sakura Yamaji ◽  
Yuji Ohgi ◽  
Humiaki Shibayama ◽  
...  

2020 ◽  
Author(s):  
Oliver A Silverson ◽  
Nicole G Cascia ◽  
Carolyn M Hettrich ◽  
Nicholas R Heebner ◽  
Tim L Uhl

Abstract Context: A single clinical assessment device that objectively measures scapular motion in each anatomical plane is not currently available. The development of a novel electric goniometer affords the ability to quantify scapular motion in all three anatomical planes. Objective: Investigate the reliability and validity of an electric goniometer to measure scapular motion in each anatomical plane during arm elevation. Design: Cross-sectional. Setting: Laboratory setting. Patients or Other Participants: Sixty participants (29 females, 31 males) were recruited from the general population. Intervention(s): An electric goniometer was used to record clinical measurements of scapular position at rest and total arc of motion (excursion) during active arm elevation in two testing sessions separated by several days. Measurements were recorded independently by two examiners. In one session, scapular motion was recorded simultaneously with a 14-camera three-dimensional optical motion capture system. Main Outcome Measures: Reliability analysis included examination of clinical measurements for scapular position at rest and excursion during each condition. Both the intra-rater reliability between testing sessions and the inter-rater reliability recorded within the same session were assessed using Intraclass Correlation Coefficients (ICC2,3). The criterion-validity was examined by comparing the mean excursion values of each condition recorded by the electric goniometer to the 3D optical motion capture system. Validity was assessed by evaluating the average difference and root mean square error (RMSE). Results: The between session intra-rater reliability was moderate to good (ICC2,3: 0.628–0.874). The within session inter-rater reliability was moderate to excellent (ICC2,3: 0.545–0.912). The average difference between the electric goniometer and 3D optical motion capture system ranged from −7° to 4° and the RMSE was between 7–10°. Conclusions: The reliability of scapular measurements is best when a standard operating procedure is used. The electric goniometer provides an accurate measurement of scapular excursions in all three anatomical planes during arm elevation.