A Response Spectrum Method for Seismic Design Evaluation of Rotating Machines

1992 ◽  
Vol 114 (4) ◽  
pp. 454-460 ◽  
Author(s):  
M. P. Singh ◽  
T. S. Chang ◽  
L. E. Suarez

The equations of motion of rotating machines subjected to seismic motions are quite complex, consisting of asymmetric general matrices with parametric and gyroscopic terms. Fortunately, the parametric and some other terms causing analytical complications can be ignored. This enables one to analyze rotating machines by a generalized modal analysis approach. This approach is used to develop a response spectrum approach for calculating the seismic design response for design inputs defined by response spectrum curves. Applicability of this proposed approach to rotor-bearing systems is verified through a time history ensemble analysis.

2021 ◽  
pp. 107754632110075
Author(s):  
Junling Chen ◽  
Jinwei Li ◽  
Dawei Wang ◽  
Youquan Feng

The steel–concrete hybrid wind turbine tower is characterized by the concrete tubular segment at the lower part and the traditional steel tubular segment at the upper part. Because of the great change of mass and stiffness along the height of the tower at the connection of steel segment and concrete segment, its dynamic responses under seismic ground motions are significantly different from those of the traditional steel tubular wind turbine tower. Two detailed finite element models of a full steel tubular tower and a steel–concrete hybrid tower for 2.0 MW wind turbine built in the same wind farm are, respectively, developed by using the finite element software ABAQUS. The response spectrum method is applied to analyze the seismic action effects of these two towers under three different ground types. Three groups of ground motions corresponding to three ground types are used to analyze the dynamic response of the steel–concrete hybrid tower by the nonlinear time history method. The numerical results show that the seismic action effect by the response spectrum method is lower than those by the nonlinear time history method. And then it can be concluded that the response spectrum method is not suitable for calculating the seismic action effects of the steel–concrete hybrid tower directly and the time history analyses should be a necessary supplement for its seismic design. The first three modes have obvious contributions on the dynamic response of the steel–concrete hybrid tower.


2009 ◽  
Vol 25 (3) ◽  
pp. 583-605 ◽  
Author(s):  
Wei Chiang Pang ◽  
David V. Rosowsky

This paper presents a direct displacement design (DDD) procedure that can be used for seismic design of multistory wood-framed structures. The proposed procedure is applicable to any pure shear deforming system. The design procedure is a promising design tool for performance-based seismic design since it allows consideration of multiple performance objectives (e.g., damage limitation, safety requirements) without requiring the engineer to perform a complex finite element or nonlinear time-history analysis of the complete structure. A simple procedure based on normalized modal analysis is used to convert the code-specified acceleration response spectrum into a set of interstory drift spectra. These spectra can be used to determine the minimum stiffness required for each floor based on the drift limit requirements. Specific shear walls can then be directly selected from a database of backbone curves. The procedure is illustrated on the design of two three-story ATC-63 archetype buildings, and the results are validated using nonlinear time-history analysis.


Author(s):  
Soon Myeon Wang ◽  
J. S. Kim ◽  
T. E. Jin ◽  
M. J. Jhung ◽  
Y. H. Choi ◽  
...  

The structural integrity of integral reactor assembly of 65Mwt thermal capacity is assessed by using the commercial finite element package ANSYS in order to evaluate the seismic safety margin. First of all, the modal analyses are performed using the various analysis models with/without the fluid coupling effect in order to validate a super element model and to evaluate the coupling effect on natural frequency. Based on the modal analysis results, the seismic analyses are performed using the ground response spectrum defined in Reg. Guide 1.60. Finally, time-history analyses are performed using the modal analysis results, the super element model and an inertia load approach. As a result, the reliable and efficient seismic analysis model for an integral reactor assembly is developed and it is found that an integral reactor assembly has the sufficient seismic safety margin.


2019 ◽  
Vol 118 ◽  
pp. 02039
Author(s):  
Jin Xiao ◽  
Mingduo Huang ◽  
Qiguo Sun

The finite element model of suspended converter valve in an UHVDC transmission project with characteristics of flexible is constructed, and its vibration characteristics are simulated and analyzed firstly. The results show that this kind of suspended converter valve has obvious long-period character. Secondly, the long period phase of standard response spectrum in Code for Seismic Design of Buildings (GB50011-2010) is modified, and then the artificial seismic wave is synthesized employing the triangular series method. The result shows that this artificial seismic wave has long-period character. Finally, the time-history seismic dynamic simulation of the converter valve is done, and the seismic responses of the converter valve excited by three kinds of seismic wave with different period characters are compared and analyzed. The results show that the swing and stress of the suspended converter valve are larger under the long-period seismic wave synthesized in this paper. The quasi-resonance damage caused by long-period seismic wave should be concerned specially in the actual UHVDC transmission project.


2013 ◽  
Vol 353-356 ◽  
pp. 2210-2215
Author(s):  
Jun Jun Wang ◽  
Lu Lu Yi

Modal analysis is also known as dynamic analysis for mode-superposition method. In the seismic response analysis of linear structural systems, it is one of the most commonly used and the most effective ways. Through the modal analysis of building structure, we can get some basic performance parameters of the structure. These parameters can help us make qualitative judgments for the respond of a structure first, and can help us judge whether they meet demands for conceptual design. Modal analysis is also the basis of other dynamic response analysis, including dynamic time history analysis and response spectrum analysis.


Author(s):  
Satoru Kai ◽  
Tomoyoshi Watakabe ◽  
Naoaki Kaneko ◽  
Kunihiro Tochiki ◽  
Makoto Moriizumi ◽  
...  

The piping in a nuclear power plant is laid across multiple floors of a single building or two buildings, which are supported at many points. As the piping is excited by multiple-inputs from the supporting points during an earthquake, seismic response analysis by multiple excitations is needed to obtain the exact seismic response of the piping. However, few experiments involving such multiple excitation have been performed to verify the validity of multiple excitation analysis. Therefore, analysis of the seismic design of piping in Japan is performed by the enveloped Floor Response Spectrum (FRS), which covers all floor response spectra at all supporting points. The piping response estimated by enveloped FRS is conservative in most cases compared with the actual seismic response by multiple excitations. To perform rational seismic design and evaluation, it is important to investigate the seismic response by multiple excitations and to verify the validity of the analytical method by multiple excitation test. This paper reports the validation results of the multiple-excitation analysis of piping compared with the results of the multiple excitations shaking test using triple uni-axial shaking table and a 3-dimensional piping model (89.1mm diameter and 5.5mm thickness). Three directional moments from the analysis and the shaking test were compared on the validation. As the result, it is confirmed that the analysis by multiple time history excitation corresponds with the test result.


2012 ◽  
Vol 5 ◽  
pp. 183-188
Author(s):  
Lian Zhen Zhang ◽  
Tian Liang Chen

Self-anchored suspension bridge is widely used in Chinese City bridge engineering for the past few years. Because the anchorage system of main cable has been changed from anchorage blocks to the ends of the girder, its’ dynamic mechanics behavior is greatly distinguished with the traditional earth anchored suspension bridge. This paper studies the dynamic characteristics and seismic response of one large-span self-anchored suspension bridge which is located in China/Shenyang city. Using a spatial dynamic analysis finite element mode, the dynamic characteristics are calculated out. An artificial seismic wave is adopted as the ground motion input which is fitted with acceleration response spectrum according to the Chinese bridge anti-seismic design code. Time-integration method is used to get the seismic time-history response. Geometry nonlinear effect is considered during the time-history analysis. At last, the dynamic characteristics and the behavior of earthquake response of this type bridge structure are discussed clearly. The research results can be used as the reference of seismic response analysis and anti-seismic design for the same type of bridge.


2020 ◽  
Vol 10 (11) ◽  
pp. 3942 ◽  
Author(s):  
Heungbae Gil ◽  
Kyoungbong Han ◽  
Junho Gong ◽  
Dooyong Cho

In areas of civil engineering, the resilient friction base isolator (R-FBI) system has been used due to its enhanced isolation performance under seismic excitations. However, because nonlinear behavior of the R-FBI should be reflected in seismic design, effective stiffness (Keff) of the R-FBI is uniformly applied at both peak ground acceleration (PGA) of 0.08 g and 0.154 g which use a multimodal response spectrum (RS) method analysis. For rational seismic design of bridges, it should be required to evaluate the dynamics of the R-FBI from in-field tests and to improve the seismic design procedure based on the performance level of the bridges. The objective of this study is to evaluate the dynamics of the R-FBI and to suggest the performance-based seismic design method for cable-supported bridges with the R-FBI. From the comparison between the experiments’ results and modal shape analyses, the modal shape analyses using primary (Ku) or infinite stiffness (fixed end) showed a great agreement with the experimental results compared to the application of Keff in the shape analysis. Additionally, the RS or nonlinear time history method analyses by the PGA levels should be applied by reflecting the dynamic characteristics of the R-FBI for the reasonable and efficient seismic design.