Two-Phase Flow-Induced Vibration: An Overview (Survey Paper)

1994 ◽  
Vol 116 (3) ◽  
pp. 233-253 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor

Two-phase flow exists in many industrial components. To avoid costly vibration problems, sound technology in the area of two-phase flow-induced vibration is required. This paper is an overview of the principal mechanisms governing vibration in two-phase flow. Dynamic parameters such as hydrodynamic mass and damping are discussed. Vibration excitation mechanisms in axial flow are outlined. These include fluidelastic instability, phase-change noise, and random excitation. Vibration excitation mechanisms in cross-flow, such as fluidelastic instability, periodic wake shedding, and random excitation, are reviewed.

1991 ◽  
Vol 113 (2) ◽  
pp. 234-241 ◽  
Author(s):  
S. S. Chen

Two-phase flow exists in many shell-and-tube heat exchangers and power generation components. The flowing fluid is a source of energy that can induce small-amplitude subcritical oscillations and large-amplitude dynamic instabilities. In fact, many practical system components have experienced excessive flow-induced vibrations. This paper reviews the current understanding of vibration of circular cylinders in quiescent fluid, cross-flow, and axial flow, with emphasis on excitation mechanisms, mathematical models, and available experimental data. A unified theory is presented for cylinders oscillating under different flow conditions.


Author(s):  
Deepanjan Mitra ◽  
Vijay K. Dhir ◽  
Ivan Catton

In the past, fluid-elastic instability in two-phase flow has been largely investigated with air-water flow. In this work, new experiments are conducted in air-water cross-flow with a fully flexible 5 × 3 normal square array having pitch-to-diameter ratio of 1.4. The tubes have a diameter of 0.016 m and a length of 0.21 m. The vibrations are measured using strain gages installed on piano wires used to suspend the tubes. Experiments are carried out for void fractions from 0%–30%. A comparison of the results of the current tests with previous experiments conducted in air-water cross-flow shows that instability occurs earlier in a fully flexible array as compared to a flexible tube surrounded by rigid tubes in an array. An attempt is made to separate out the effects of structural parameters of three different experimental datasets by replotting the instability criterion by incorporating the instability constant K, in the reduced velocity parameter.


Author(s):  
H. Senez ◽  
N. W. Mureithi ◽  
M. J. Pettigrew

Two-phase cross flow exists in many shell-and-tube heat exchangers. Flow-induced vibration excitation forces can cause tube motion that will result in long-term fretting wear or fatigue. Detailed flow and vibration excitation force measurements in tube bundles subjected to two-phase cross flow are required to understand the underlying vibration excitation mechanisms. Studies on this subject have already been done, providing results on flow regimes, fluidelastic instabilities, and turbulence-induced vibration. The spectrum of turbulence-induced forces has usually been expected to be similar to that in single-phase flow. However, a recent study, using tubes with a diameter larger than that in a real steam generator, showed the existence of significant quasi-periodic forces in two-phase flow. An experimental program was undertaken with a rotated-triangular array of cylinders subjected to air-water cross-flow, to simulate two-phase mixtures. The tube bundle here has the same geometry as that of a real steam generator. The quasi-periodic forces have now also been observed in this tube bundle. The present work aims to understand turbulence-induced forces acting on the tube bundle, providing results on drag and lift force spectra and their behaviour according to flow parameters, and describing their correlations. Detailed experimental test results are presented in this paper. Comparison is also made with previous measurements with larger diameter tubes. The present results suggest that quasi-periodic fluid forces are not uncommon in tube arrays subjected to two-phase cross-flow.


Author(s):  
W. G. Sim

Two-phase cross flow exists in many shell- and tube heat exchangers such as condensers, evaporators and nuclear steam generators. During the last two decades, research devoted to two-phase flow induced vibrations has increased, mainly driven by the nuclear industry. Flow-induced vibration excitation forces can cause excessive vibration which will result in long-term fretting-wear or fatigue. To avoid potential tube failures in heat exchangers, it is required for designer to have guidelines that incorporate flow-induced vibration excitation forces. The phenomenon of the vibration of tubes in two-phase flow is very complex and depends on factors which are nonexistent in single-phase flows. To understand the fluid dynamic forces acting on a structure subjected to two-phase flow, it is essential to get detailed information about the characteristics of two-phase flow. Pressure distributions generated by two-phase flow over tube surfaces yield more general information than the local velocity distribution. The pressure coefficient distribution obtained by experimental test has been evaluated.


1995 ◽  
Vol 117 (4) ◽  
pp. 321-329 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor ◽  
J. H. Jong ◽  
I. G. Currie

Two-phase cross-flow exists in many shell-and-tube heat exchangers. The U-bend region of nuclear steam generators is a prime example. Testing in two-phase flow simulated by air-water provides useful results inexpensively. However, two-phase flow parameters, in particular surface tension and density ratio, are considerably different in air-water than in steam-water. A reasonable compromise is testing in liquid-vapor Freon, which is much closer to steam-water while much simpler experimentally. This paper presents the first results of a series of tests on the vibration behavior of tube bundles subjected to two-phase Freon cross-flow. A rotated triangular tube bundle of tube-to-diameter ratio of 1.5 was tested over a broad range of void fractions and mass fluxes. Fluidelastic instability, random turbulence excitation, and damping were investigated. Well-defined fluidelastic instabilities were observed in continuous two-phase flow regimes. However, intermittent two-phase flow regimes had a dramatic effect on fluidelastic instability. Generally, random turbulence excitation forces are much lower in Freon than in air-water. Damping is very dependent on void fraction, as expected.


2004 ◽  
Vol 126 (4) ◽  
pp. 523-533 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor

Two-phase flow exists in many shell-and-tube heat exchangers such as condensers, evaporators, and nuclear steam generators. Some knowledge on tube damping mechanisms is required to avoid flow-induced vibration problems. This paper outlines the development of a semi-empirical model to formulate damping of heat exchanger tube bundles in two-phase cross flow. The formulation is based on information available in the literature and on the results of recently completed experiments. The compilation of a database and the formulation of a design guideline are outlined in this paper. The effects of several parameters such as flow velocity, void fraction, confinement, flow regime and fluid properties are discussed. These parameters are taken into consideration in the formulation of a practical design guideline.


Author(s):  
Laurent Borsoi ◽  
Philippe Piteau ◽  
Xavier Delaune ◽  
Jose Antunes

Flow-induced vibration of heat-exchangers tubes is particularly studied in the nuclear industry for safety and cost reasons. It implies to have, among others, relevant characterizations of the random buffeting forces the cross-flow applies to the tube bundle. Work is still needed in this domain, particularly for two-phase flow, to improve the available data as the ones for PWR steam generator, currently very envelope. In parallel to get new experimental data, using “real” or substitutional mixtures (e.g. air-water instead of steam-water for PWR), it is essential to understand the basic excitation mechanisms which induce the vibrations under two-phase flow, as e.g. the influence of flow regimes. In this general framework, what can be learnt from deliberately simple models may be a contributive help. As a first attempt on this issue, the paper deals with the elementary case of a single rigid tube under air-water cross flow. This case is part of experiments carried out at CEA-Saclay with bundles where both tube support reactions and flow characteristics are measured, with respectively piezo-electrical sensors and bi-optical probes (BOP). The information provided by the BOP (mean interface velocity, statistical distribution, etc.) feeds a primitive model of water “droplet” impulses on the tube, based on a lot of crude assumptions about impact velocity, momentum conservation, impulse shape, statistical independence, etc., and which uses analytical results of random processes constructed from the superposition of random pulses. The “equivalent” excitation force, obtained in terms of dimensional PSD, is compared to the one measured in the drag and lift direction with an acceptable agreement, at least in order of magnitude. Comments and lessons are drawn from this first attempt, and some paths are advanced to improve this kind of primitive models, especially for treating rigid square bundles under air-water cross flow.


2009 ◽  
Vol 131 (3) ◽  
Author(s):  
Paul Feenstra ◽  
David S. Weaver ◽  
Tomomichi Nakamura

Laboratory experiments were conducted to determine the flow-induced vibration response and fluidelastic instability threshold of model heat exchanger tube bundles subjected to a cross-flow of refrigerant 11. Tube bundles were specially built with tubes cantilever-mounted on rectangular brass support bars so that the stiffness in the streamwise direction was about double that in the transverse direction. This was designed to simulate the tube dynamics in the U-bend region of a recirculating-type nuclear steam generator. Three model tube bundles were studied, one with a pitch ratio of 1.49 and two with a smaller pitch ratio of 1.33. The primary intent of the research was to improve our understanding of the flow-induced vibrations of heat exchanger tube arrays subjected to two-phase cross-flow. Of particular concern was to compare the effect of the asymmetric stiffness on the fluidelastic stability threshold with that of axisymmetric stiffness arrays tested most prominently in literature. The experimental results are analyzed and compared with existing data from literature using various definitions of two-phase fluid parameters. The fluidelastic stability thresholds of the present study agree well with results from previous studies for single-phase flow. In two-phase flow, the comparison of the stability data depends on the definition of two-phase flow velocity.


Author(s):  
R. Violette ◽  
N. W. Mureithi ◽  
M. J. Pettigrew

Tests were done to study the fluidelastic instability of a cluster of seven cylinders much more flexible in the flow direction than in the lift direction. The array configuration is rotated triangular with a pitch to diameter ratio of 1.5. The array was subjected to two-phase (air-water) cross flow. Cylinder natural frequencies of 14 and 28 Hz were tested. Fluidelastic instabilities were observed at 65, 80, 90 and 95% void fraction albeit at a somewhat higher flow velocity than that expected for axisymetrically flexible arrays. These results and additional wind tunnel results are compared to existing data on fluidelastic instability.


Author(s):  
Paul Feenstra ◽  
David S. Weaver ◽  
Tomomichi Nakamura

Laboratory experiments were conducted to determine the flow-induced vibration response and fluidelastic instability threshold of a model heat exchanger tube bundle subjected to a cross-flow of refrigerant 11. Tube bundles were specially built with cantilevered tubes mounted on asymmetric supports so that the stiffness in the streamwise direction was about double that of the transverse direction. This was designed to simulate the tube dynamics in the U-bend region of a recirculating-type nuclear steam generator. Three model tube bundles were tested, one with a pitch ratio of 1.49 and two with a smaller pitch ratio of 1.33. The primary intent of the research was to improve our understanding of the flow-induced vibrations of heat exchanger tube arrays subjected to two-phase cross-flow. Of particular concern was to compare the effect of the asymmetric support stiffness on the fluidelastic stability threshold with that of symmetric stiffness arrays tested most prominently in the literature. The experimental results are analysed and compared with existing data from the literature using various definitions of two-phase fluid parameters. The fluidelastic stability thresholds of the present study agree well with results from previous studies for single phase flow. In two-phase flow, the comparison of the stability data depends upon the definition of two-phase flow velocity.


Sign in / Sign up

Export Citation Format

Share Document