Numerical Analysis of the Cooling Effect of Blood Over Inflamed Atherosclerotic Plaque

2008 ◽  
Vol 130 (3) ◽  
Author(s):  
Taehong Kim ◽  
Obdulia Ley

Atherosclerotic plaques with high likelihood of rupture often show local temperature increase with respect to the surrounding arterial wall temperature. In this work, atherosclerotic plaque temperature was numerically determined during the different levels of blood flow reduction produced by the introduction of catheters at the vessel lumen. The temperature was calculated by solving the energy equation and the Navier–Stokes equations in 2D idealized arterial models. Arterial wall temperature depends on three basic factors: metabolic activity of the inflammatory cells embedded in the plaque, heat convection due to luminal blood flow, and heat conduction through the arterial wall and plaque. The calculations performed serve to simulate transient blood flow reduction produced by the presence of thermography catheters used to measure arterial wall temperature. The calculations estimate the spatial and temporal alterations in the cooling effect of blood flow and plaque temperature during the measurement process. The mathematical model developed provides a tool for analyzing the contribution of factors known to affect heat transfer at the plaque surface. Blood flow reduction leads to a nonuniform temperature increase ranging from 0.1°Cto0.25°Celsius in the plaque/lumen interface of the arterial geometries considered in this study. The temperature variation as well as the Nusselt number calculated along the plaque surface strongly depended on the arterial geometry and distribution of inflammatory cells. The calculations indicate that the minimum required time to obtain a steady temperature profile after arterial occlusion is 6s. It was seen that in arteries with geometries involving bends, the temperature profiles appear asymmetrical and lean toward the downstream edge of the plaque.

2005 ◽  
Vol 21 (s2) ◽  
pp. 55-59 ◽  
Author(s):  
J. Hata ◽  
T. Kamada ◽  
N. Manabe ◽  
H. Kusunoki ◽  
D. Kamino ◽  
...  

Author(s):  
Yusuke SHIMIZU ◽  
Susumu ISHIKAWA ◽  
Hideki MISHIMA ◽  
Yuki MATSUNAGA ◽  
Yuki NISHIHARA ◽  
...  

2011 ◽  
Vol 171 (2) ◽  
pp. 532-539 ◽  
Author(s):  
Ruy J. Cruz ◽  
Alejandra G. Garrido ◽  
Décio de Natale Caly ◽  
Mauricio Rocha-e-Silva

Neurology ◽  
2002 ◽  
Vol 59 (3) ◽  
pp. 321-326 ◽  
Author(s):  
M. O'Sullivan ◽  
D. J. Lythgoe ◽  
A. C. Pereira ◽  
P. E. Summers ◽  
J. M. Jarosz ◽  
...  

2019 ◽  
Vol 51 (2) ◽  
pp. 130-136
Author(s):  
Franca Tecchio ◽  
Federico Cecconi ◽  
Elisabetta Colamartino ◽  
Matteo Padalino ◽  
Luca Valci ◽  
...  

Somatosensory evoked potential (SEP) monitoring is a standard tool during clipping of aneurysms of the middle cerebral artery (MCA), and the parameter used to detect a state of cortical ischemia is amplitude. We think that the sensitivity of SEP can however be improved by using other parameters. Our study moves in this direction via SEP morphology. In this pilot preliminary study, involving a small sample without postoperative neurological deficit, we aimed at investigating the value of SEP morphology (in the 15- to 35-ms time frame), in comparison with SEP amplitude (N20 peak-to-peak), as a measure of sensitivity to blood flow reduction. The changes in the SEP morphology of 16 patients undergoing clipping of an unruptured MCA aneurysm was studied. We applied the Morph-Fréchet index for each recorded SEP (at 30-second intervals), quantifying the pattern shape change with regard to the average SEP recorded after dura opening (baseline). We also compared 3 measurements of the SEP morphology, without and with GARCH-derived filter. Filtered Morph-Fréchet never exceeded the individual’s “normality” range in baseline but did so in 81% of the risk phase on average across the 16 subjects, which is more than that for amplitude (36%, P = .002). This pilot study indicates that a measurement derived from the networking nature of the brain was sensitive to blood flow reduction. The SEP morphology approach promises to improve SEP monitoring sensitivity during clipping of unruptured MCA aneurysms. New and Noteworthy. The higher sensitivity to blood flow reduction of SEP morphology than amplitude promises to improve the effectiveness of intraoperative monitoring during MCA aneurysm clipping procedures.


1996 ◽  
Vol 270 (1) ◽  
pp. R246-R253 ◽  
Author(s):  
D. W. Boyle ◽  
S. Lecklitner ◽  
E. A. Liechty

The purpose of the present investigation was to study the effect of 7 days of uterine blood flow reduction on fetal growth. Reduction in uterine blood flow was accomplished by external occlusion of the terminal aorta in 20 pregnant sheep. Linear growth was monitored daily by means of a crown-rump length measuring device. The deliveries of oxygen, glucose, and lactate to the fetus, as well as their uptakes by the fetus, were determined before and after 7 days of uterine blood flow reduction and correlated with rates of fetal growth. Identical studies were conducted in nine control animals. Uterine blood flow reduction resulted in a significant decrease in fetal oxygen delivery and fetal arterial oxygen content. Linear growth rate decreased by 38% in the occluded animals during hypoxemia. In addition, there was a 20% reduction in daily weight gain in occluded animals compared with controls. There were no differences in the uptakes of oxygen, glucose, and lactate by the fetus. Positive correlations were found between linear growth rate and fetal arterial oxygen content (r2 = 0.25, P = 0.0001) and between linear growth rate and fetal oxygen delivery (r2 = 0.21, P = 0.0006). The correlations between linear growth rate and fetal oxygenation provide strong evidence of the central role of oxygen in the regulation of fetal growth.


Sign in / Sign up

Export Citation Format

Share Document