1990 Max Jakob Memorial Award Lecture: Viscoelastic Fluids: A New Challenge in Heat Transfer

1992 ◽  
Vol 114 (2) ◽  
pp. 296-303 ◽  
Author(s):  
J. P. Hartnett

A review of the current knowledge on the fluid mechanics and heat transfer behavior of viscoelastic aqueous polymer solutions in channel flow is presented. Both turbulent and laminar flow conditions are considered. Although the major emphasis is on fully established circular pipe flow, some results are also reported for flow in a 2:1 rectangular channel. For fully established turbulent channel flow, it was found that the friction factor, f, and the dimensionless heat transfer factor, jH, were functions of the Reynolds number and a dimensionless elasticity value, the Weissenberg number. For Weissenberg values greater than approximately 10 (the critical value) the friction factor was found to be a function only of the Reynolds number; for values less than 10 the friction factor was a function of both Re and Ws. For the dimensionless heat transfer coefficient jH the corresponding critical Weissenberg value was found to be about 100. The heat transfer reduction is always greater than the friction factor reduction; consequently, the heat transfer per unit pumping power decreases with increasing elasticity. For fully established laminar pipe flow of aqueous polymer solutions, the measured values of the friction factor and dimensionless heat transfer coefficient were in excellent agreement with the values predicted for a power law fluid. For laminar flow in a 2:1 rectangular channel the fully developed friction factor measurements were also in agreement with the power law prediction. In contrast, the measured local heat transfer coefficients for aqueous polymer solutions in laminar flow through the 2:1 rectangular duct were two to three times the values predicted for a purely viscous power law fluid. It is hypothesized that these high heat transfer coefficients are due to secondary motions, which come about as a result of the unequal normal stresses occurring in viscoelastic fluids. The anomalous behavior of one particular aqueous polymer solution—namely, polyacrylic acid (Carbopol)—is described in some detail, raising some interesting questions as to how viscoelastic fluids should be classified. In closing, a number of challenging research opportunities in the study of viscoelastic fluids are presented.

2006 ◽  
Author(s):  
Dennis A. Siginer ◽  
Mario F. Letelier

A survey of the developments in heat transfer studies of non-linear inelastic as well as elastic fluids in tubes is given. Experimental findings concerning heat transfer enhancement characteristics of viscoelastic aqueous polymer solutions are very significant. Specifically, it is reported that heat transfer results for viscoelastic aqueous polymer solutions are drastically higher than those found for water in laminar flow in rectangular ducts. A number of investigators suggested that the high experimental heat transfer values were due to secondary flows resulting from the elasticity of the fluids. In this context recent results concerning the fully developed thermal field in constant pressure gradient driven laminar flow of a class of viscoelastic fluids characterized by single mode, non-affine constitutive equations in straight pipes of arbitrary contour ∂D is reviewed. Heat transfer enhancement due to shear-thinning is identified together with the enhancement due to the inherent elasticity of the fluid. The latter is the result of secondary flows in the cross-section. Increasingly large enhancements are computed with increasing elasticity of the fluid as compared to its Newtonian counterpart. Large enhancements are possible even with dilute fluids. Isotherms for the temperature field are presented and discussed for several non-circular contours such as the ellipse and the equilateral triangle together with heat transfer behavior in terms of the Nusselt number Nu.


Author(s):  
Mei Wang ◽  
Yan Wen ◽  
Suizheng Qiu ◽  
Guanghui Su ◽  
Weifeng Ni

The purpose of this study is to discover the differences of pressure drop and heat transfer of single-phase water flow between conventional channels and narrow rectangular channels. Furthermore, the differences between the level and the vertical channel have been studied. The gap of the test channel is 1.8mm. Compared with conventional channels, the narrow rectangular channel showed differences in both flow and heat transfer characteristics. The critical Reynolds number of transition from laminar flow to turbulent flow is 900∼1300, which is smaller compared with conventional channels. The friction factor is larger than that of the conventional channels and the correlation of friction factor with Reynolds number was given by experimental results. From the relation graph of Nusselt number and Reynolds number, the demarcation of the laminar flow region and turbulence flow region is obvious. In laminar region, Nusselt number almost remained constant and approximately consistent with numerical simulation results. While in turbulent region, Nusselt number increased significantly with increasing Reynolds number. A new Nusselt number correlation was obtained based on Dittus-Boelter equation, and the coefficients were less about 13% than that of Dittus-Boelter equation.


Author(s):  
S. V. Prabhu ◽  
R. P. Vedula

A modified geometry for the internal cooling passages of a gas turbine rotor blade is suggested here. In this modified geometry, the Coriolis force induced enhanced heat transfer coefficients are experienced by both the coolant channel walls adjacent to the blade pressure and blade suction surfaces. This is made possible by permitting the flow to have a radially outward and a radially inward direction at different locations along the blade thickness at a given chordwise location. However, the flow geometry is complex and the corresponding pressure losses are also likely to be larger. The present investigation is a preliminary study of the pressure drop characteristics for the modified channel suggested above and the simplest case of a straight channel with ribs on only one surface is reported here. The pressure drop in a rectangular cross-sectioned duct with an aspect ratio of 2.0 rotating about an axis normal to the free-stream direction in the presence of rib turbulators glued on one of the surfaces of the test section with ribs normal to the flow direction is measured. The study has been conducted for Reynolds number varying from 10000–17000 and the rotation number varying from 0–0.21. Experiments were carried out for various pitch-to-rib height ratios (P/e) of 3, 5, 7.5 & 10 with a constant rib height-to-hydraulic diameter ratio (e/D) of 0.15. A significant increase of the friction factor is observed when the ribbed surface is the coolant channel trailing (pressure) surface in the presence of rotation. The highest friction factor is observed in a channel with a P/e ratio of 5 which would imply that there could be a significant increase in the heat transfer coefficient for this configuration. A pitch-to-height ratio of about 10, which is the most preferred choice for a stationary configuration, no longer appears to be the optimum in the presence of rotation.


1987 ◽  
Vol 109 (3) ◽  
pp. 599-605 ◽  
Author(s):  
An-Shik Yang ◽  
Ching-Chang Chieng

An anisotropic factor is carefully selected from eleven distributions and adopted to the k–ε two-equation model of turbulence to obtain detailed velocity and temperature fields for steady-state, fully developed turbulent flow through infinite triangular/square rod array. The present study covers the ranges of pitch-to-diameter ratio from 1.123 to 1.5, and Reynolds number from 2.4 × 104 to 106. Velocity and wall shear stress are calculated and compared to experimental data. Normalized fluid temperature, friction factor, and heat transfer coefficient are also computed. The correlations of friction factor and heat transfer coefficients for flow inside circular pipe and flow through finite rod arrays are compared with the results for flow through infinite rod arrays.


2005 ◽  
Vol 128 (6) ◽  
pp. 557-563 ◽  
Author(s):  
Paul L. Sears ◽  
Libing Yang

Heat transfer coefficients were measured for a solution of surfactant drag-reducing additive in the entrance region of a uniformly heated horizontal cylindrical pipe with Reynolds numbers from 25,000 to 140,000 and temperatures from 30to70°C. In the absence of circumferential buoyancy effects, the measured Nusselt numbers were found to be in good agreement with theoretical results for laminar flow. Buoyancy effects, manifested as substantially higher Nusselt numbers, were seen in experiments carried out at high heat flux.


Author(s):  
Sam Ghazi-Hesami ◽  
Dylan Wise ◽  
Keith Taylor ◽  
Peter Ireland ◽  
Étienne Robert

Abstract Turbulators are a promising avenue to enhance heat transfer in a wide variety of applications. An experimental and numerical investigation of heat transfer and pressure drop of a broken V (chevron) turbulator is presented at Reynolds numbers ranging from approximately 300,000 to 900,000 in a rectangular channel with an aspect ratio (width/height) of 1.29. The rib height is 3% of the channel hydraulic diameter while the rib spacing to rib height ratio is fixed at 10. Heat transfer measurements are performed on the flat surface between ribs using transient liquid crystal thermography. The experimental results reveal a significant increase of the heat transfer and friction factor of the ribbed surface compared to a smooth channel. Both parameters increase with Reynolds number, with a heat transfer enhancement ratio of up to 2.15 (relative to a smooth channel) and a friction factor ratio of up to 6.32 over the investigated Reynolds number range. Complementary CFD RANS (Reynolds-Averaged Navier-Stokes) simulations are performed with the κ-ω SST turbulence model in ANSYS Fluent® 17.1, and the numerical estimates are compared against the experimental data. The results reveal that the discrepancy between the experimentally measured area averaged Nusselt number and the numerical estimates increases from approximately 3% to 13% with increasing Reynolds number from 339,000 to 917,000. The numerical estimates indicate turbulators enhance heat transfer by interrupting the boundary layer as well as increasing near surface turbulent kinetic energy and mixing.


2017 ◽  
Vol 41 (5) ◽  
pp. 771-786 ◽  
Author(s):  
Ashif Perwez ◽  
Shreyak Shende ◽  
Rakesh Kumar

An experimental and numerical investigation is performed to study the effect of dimple and protrusion geometry on the heat transfer enhancement and the friction factor of surfaces with dimples and protrusions subjected to turbulent flow. The parameters used to compare the spherical dimples and protrusions are Nusselt Number, friction factor, and flow pattern. These parameters are obtained for a Reynolds number of 10500-60900. The spherical dimple results showed the greater heat transfer, which is about 6.97% higher and pressure loss which is 5.07% lower than the spherical protrusion. The realistic heat transfer augmentation capabilities of channels with dimples and protrusions can be studied from the experimental results. The comparison is made with respect to the smooth rectangular channel under the same flow and thermal boundary conditions. The numerical analysis is performed which shows the different vortex flow structures of the spherical dimples and protrusions channel.