Forced Convective Boiling of Nonazeotropic Refrigerant Mixtures Inside Tubes

1993 ◽  
Vol 115 (3) ◽  
pp. 680-689 ◽  
Author(s):  
K. Murata ◽  
K. Hashizume

Forced convective boiling of nonazeotropic mixtures inside horizontal tubes was investigated experimentally. The heat transfer coefficient and pressure drop of pure refrigerant R123 and a mixture of R123 and R134a were measured in both a smooth tube and a spirally grooved tube. The heat transfer coefficient for the mixture was found to be lower than that for an equivalent pure refrigerant with the same phsycial properties, not only in the boiling-dominant region but also in the convection-dominant region. On the basis of this experiment, correlations were proposed for heat transfer coefficients in smooth and grooved tubes; the reduction in heat transfer coefficient for the mixture is attributed to the mixture effects on nucleate boiling and to the heat transfer resistance in the vapor phase. This heat transfer resistance is caused by the sensible heating of the vapor phase accompanying the rise in saturation temperature. These correlations are able to predict the heat transfer data within ± 20 percent

Author(s):  
Nae-Hyun Kim ◽  
Wang-Kyu Oh ◽  
Jung-Ho Ham ◽  
Do-Young Kim ◽  
Tae-Ryong Shin

Convective boiling heat transfer coefficients of R-22 were obtained in a flat extruded aluminum tube with Dh = 1.41 mm. The test range covered mass flux from 100 to 600 kg/m2 s, heat flux from 5 to 15 kW/m2 and saturation temperature from 5°C to 15°C. The heat transfer coefficient curve shows a decreasing trend after a certain quality (critical quality). The critical quality decreases as the heat flux increases, and as the mass flux decreases. The early dryout at a high heat flux results in a unique ‘cross-over’ of the heat transfer coefficient curves. The heat transfer coefficient increases as the mass flux increases. At a low quality region, however, the effect of mass flux is not prominent. The heat transfer coefficient increases as the saturation temperature increases. The effect of saturation temperature, however, diminishes as the heat flux decreases. Both the Shah and the Kandlikar correlations underpredict the low mass flux and overpredict the high mass flux data.


Energies ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 160 ◽  
Author(s):  
Bartosz Gil ◽  
Beata Fijałkowska

This paper investigates the nucleate boiling process of dimethyl ether and selected hydrocarbons. The main goal of this study is to measure the heat transfer coefficients of RE170, R600a, and R601, and to compare them with R134a. The experiments were carried out for heat fluxes up to 70 kW/m2. Experimental results have shown a typical trend that the heat transfer coefficient of flammable refrigerants increases as the heat flux increases. Among the tested fluids, the highest values of heat transfer coefficient were obtained for RE170. Available correlations describing this coefficient showed a deviation of up to 93%, as compared to the data obtained. The new correlation was developed by regression analysis taking into account dimensionless variables affecting the boiling process.


Author(s):  
Nae-Hyun Kim ◽  
Young-Sup Sim ◽  
Chang-Keun Min

Convective boiling heat transfer coefficients of R-22 were obtained in a flat extruded aluminum tube with Dh = 1.41 mm. The test range covered mass flux from 200 to 600 kg/m2 s, heat flux from 5 to 15 kW/m2 and saturation temperature from 5°C to 15°C. The heat transfer coefficient curve shows a decreasing trend after a certain quality (critical quality). The critical quality decreases as the heat flux increases, and as the mass flux decreases. The early dryout at a high heat flux results in a unique ‘cross-over’ of the heat transfer coefficient curves. The heat transfer coefficient increases as the mass flux increases. At a low quality region, however, the effect of mass flux is not prominent. The heat transfer coefficient increases as the saturation temperature increases. The effect of saturation temperature, however, diminishes as the heat flux decreases. Both the Shah and the Kandlikar correlations underpredict the low mass flux and overpredict the high mass flux data.


Author(s):  
Stefano Bortolin ◽  
Alberto Cavallini ◽  
Davide Del Col ◽  
Marko Matkovic ◽  
Luisa Rossetto

The present paper reports the heat transfer coefficients measured during flow boiling of HFC-32 and HFC-134a in a 0.96 mm diameter single circular channel. The test runs have been performed during vaporization at around 30°C saturation temperature, correspondent to 19.3 bar for R32 and 7.7 bar for R134a. As a peculiar characteristic of the present technique, the heat transfer coefficient is not measured by imposing the heat flux; instead, the boiling process is governed by controlling the inlet temperature of the heating secondary fluid. The quality of the inner surface of the test tube has been measured to check the influence of surface roughness on the heat transfer coefficient. The flow boiling data taken in the present test section is presented and discussed, with particular regard to the effect of heat flux, mass velocity, vapor quality and fluid properties.


2018 ◽  
Vol 17 (2) ◽  
pp. 57
Author(s):  
H. L. S. L. Leão ◽  
D. B. Marchetto ◽  
G. Ribatski

A comparative study of the performance of of refrigerants R134a, R407C, R245fa and R600a during flow boiling was performed for a 123x494 µm2 heat sink composed of 50 parallel rectangular microchannels. Heat transfer experimental results for heat fluxes up to 310 kW/m2, mass velocities from 300 to 800 kg/(m2 s), liquid subcoolings of 5 and 10 °C and saturation temperature close to 30 ºC were obtained. Global heat transfer coefficients (footprint) up to 10 kW/(m2 °C) were found. The liquid superheating necessary for the onset of nucleate boiling (ONB) was also characterized, and the fluids R245fa and R407C presented the highest and lowest, respectively, superheating to trigger the boiling process. Moreover, for a fixed averaged vapor quality, the average effective heat transfer coefficient increases with increasing mass velocity and liquid subcooling. The refrigerants R600a and R407C presented the highest and the lowest heat transfer coefficients, respectively. Five heat transfer predictive methods from literature provided accurate predictions of the data for R134a, R245fa and R600a, capturing most of the data trends. No one method provided accurate predictions of the heat transfer coefficient data of R407C.


Author(s):  
Ann-Christin Fleer ◽  
Markus Richter ◽  
Roland Span

AbstractInvestigations of flow boiling in highly viscous fluids show that heat transfer mechanisms in such fluids are different from those in fluids of low viscosity like refrigerants or water. To gain a better understanding, a modified standard apparatus was developed; it was specifically designed for fluids of high viscosity up to 1000 Pa∙s and enables heat transfer measurements with a single horizontal test tube over a wide range of heat fluxes. Here, we present measurements of the heat transfer coefficient at pool boiling conditions in highly viscous binary mixtures of three different polydimethylsiloxanes (PDMS) and n-pentane, which is the volatile component in the mixture. Systematic measurements were carried out to investigate pool boiling in mixtures with a focus on the temperature, the viscosity of the non-volatile component and the fraction of the volatile component on the heat transfer coefficient. Furthermore, copper test tubes with polished and sanded surfaces were used to evaluate the influence of the surface structure on the heat transfer coefficient. The results show that viscosity and composition of the mixture have the strongest effect on the heat transfer coefficient in highly viscous mixtures, whereby the viscosity of the mixture depends on the base viscosity of the used PDMS, on the concentration of n-pentane in the mixture, and on the temperature. For nucleate boiling, the influence of the surface structure of the test tube is less pronounced than observed in boiling experiments with pure fluids of low viscosity, but the relative enhancement of the heat transfer coefficient is still significant. In particular for mixtures with high concentrations of the volatile component and at high pool temperature, heat transfer coefficients increase with heat flux until they reach a maximum. At further increased heat fluxes the heat transfer coefficients decrease again. Observed temperature differences between heating surface and pool are much larger than for boiling fluids with low viscosity. Temperature differences up to 137 K (for a mixture containing 5% n-pentane by mass at a heat flux of 13.6 kW/m2) were measured.


2000 ◽  
Author(s):  
Edward V. McAssey ◽  
Jinfeng Wu ◽  
Thomas Dougherty ◽  
Bao Wen Yang

Abstract Data are presented for sub-cooled boiling of water in the range of two to four atmospheres. The results show that the sharp increase in heat transfer coefficient associated with nucleate boiling occurs at wall superheats of 20 °C to 30 °C. Comparisons between experimental and predicted heat transfer coefficients are also presented. The two prediction methods examined are the Chen correlation and the Kandlikar correlation.


Metals ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. 1367
Author(s):  
Nino Wolff ◽  
Golo Zimmermann ◽  
Uwe Vroomen ◽  
Andreas Bührig-Polaczek

Local heat transfer in gravity die casting is of great importance for precision in terms of distortion, mechanical properties, and the quality of the castings due to its effect on solidification. Depending on contact conditions such as liquid melt to solid mold, a gap between mold and component, or contact pressure between casting and mold as a result of shrinkage, there are very large differences in heat transfer. The influences of mold material, mold coating and its influence of aging, mold temperature control, and layout on the heat transfer coefficient (HTC) were investigated experimentally for different contact cases. The experiments were carried out on a rotationally symmetrical experimental setup with modular exchangeable die inserts and cores using an AlSi7Mg0.3 alloy. From the results of the individual test series, the quantitative shares of the above-mentioned influencing variables in the respective effective heat transfer coefficients were determined by means of analysis of variance. From this, the parameters having the most significant influence on the local heat balance were derived.


1998 ◽  
Vol 120 (4) ◽  
pp. 831-838 ◽  
Author(s):  
M. E. Taslim ◽  
G. J. Korotky

Cooling channels, roughened with repeated ribs, are commonly employed as a means of cooling turbine blades. The increased level of mixing induced by these ribs enhances the convective heat transfer in the blade cooling cavities. Many previous investigations have focused on the heat transfer coefficient on the surfaces between these ribs and only a few studies report the heat transfer coefficient on the rib surfaces themselves. The present study investigated the heat transfer coefficient on the surfaces of round-corner, low-aspect-ratio (ARrib = 0.667) ribs. Twelve rib geometries, comprising three rib height-to-channel hydraulic diameters (blockage ratios) of 0.133, 0.167, and 0.25 as well as three rib spacings (pitch-to-height ratios) of 5, 8.5, and 10 were investigated for two distinct thermal boundary conditions of heated and unheated channel walls. A square channel, roughened with low-aspect-ratio ribs on two opposite walls in a staggered manner and perpendicular to the flow direction, was tested. An instrumented copper rib was positioned either in the middle of the rib arrangements or in the furthest upstream location. Both rib heat transfer coefficient and channel friction factor for these low-aspect-ratio ribs were also compared with those of square ribs, reported previously by the authors. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the rib-roughened region of the passage wall were also compared.