Experimental and Numerical Analysis of Low-Temperature Heat Pipes With Multiple Heat Sources

1991 ◽  
Vol 113 (3) ◽  
pp. 728-734 ◽  
Author(s):  
A. Faghri ◽  
M. Buchko

A numerical analysis and experimental verification of the effects of heat load distribution on the vapor temperature, wall temperature, and the heat transport capacity for heat pipes with multiple heat sources is presented. A numerical solution of the elliptic conjugate mass, momentum and energy equations in conjunction with the thermodynamic equilibrium relations and appropriate boundary conditions for the vapor region, wick structure, and the heat pipe wall are given. The experimental testing of a copper-water heat pipe with multiple heat sources was also made showing excellent agreement with the numerical results. An optimization of the heat distribution for such heat pipes was performed and it was concluded that by redistribution of the heat load, the heat capacity can be increased.

2004 ◽  
Vol 126 (3) ◽  
pp. 347-354 ◽  
Author(s):  
Unnikrishnan Vadakkan ◽  
Suresh V. Garimella ◽  
Jayathi Y. Murthy

A three-dimensional model has been developed to analyze the transient and steady-state performance of flat heat pipes subjected to heating with multiple discrete heat sources. Three-dimensional flow and energy equations are solved in the vapor and liquid regions, along with conduction in the wall. Saturated flow models are used for heat transfer and fluid flow through the wick. In the wick region, the analysis uses an equilibrium model for heat transfer and a Brinkman-Forchheimer extended Darcy model for fluid flow. Averaged properties weighted with the porosity are used for the wick analysis. The state equation is used in the vapor core to relate density change to the operating pressure. The density change due to pressurization of the vapor core is accounted for in the continuity equation. Vapor flow, temperature and hydrodynamic pressure fields are computed at each time step from coupled continuity/momentum and energy equations in the wick and vapor regions. The mass flow rate at the interface is obtained from the application of kinetic theory. Predictions are made for the magnitude of heat flux at which dryout would occur in a flat heat pipe. The input heat flux and the spacing between the discrete heat sources are studied as parameters. The location in the heat pipe at which dryout is initiated is found to be different from that of the maximum temperature. The location where the maximum capillary pressure head is realized also changes during the transient. Axial conduction through the wall and wick are seen to play a significant role in determining the axial temperature variation.


Warmth pipes come convenient now-a-days as they work with most noteworthy warmth conductance contrasted with some other method of warmth move and accessible over wide scope parameters. In the present investigation de-ionized water stream in plain thermo siphon, Sintered Copper wick and Helical scored heat pipes with synchronous vanishing, adiabatic and buildup wonder are contemplated utilizing Heat pipe test gear. In this hardware warmth pipe exposed to foreordain heat load an obstruction radiator at its evaporator end water coat with controlled progression water is utilized disperse warmth vitality at condenser end. Every one temperatures are estimated necessary computations are done get rate efficiencies at different stream rates warmth inputs. The exhibition warmth funnels correlation between their efficiencies is done. The sintered copper wick structure pipe have been found capable when stood out from other two with heat inputs beginning from 50 to 800 watts evaporator 30, condenser 72, adiabatic 110, flate heat pipe width 7.6mm, thickness 3.4 mm, first dia 6mm warmth pipe holder thickness in 0.5mm working liquid ethanol wick in view prevailing Capillarity property. The varieties of evaporator and condenser surface temperatures are plotted for changing warmth information sources and stream rate changes at condenser water coat. ANSYS programming is utilized for computational investigation and exploratory outcomes are in great concurrence with the examination.


Author(s):  
Unnikrishnan Vadakkan ◽  
Suresh V. Garimella ◽  
Jayathi Y. Murthy

A three-dimensional model has been developed to analyze the transient and steady-state performance of flat heat pipes with discrete heat sources. Three-dimensional flow and energy equations are solved in the vapor and liquid regions, along with conduction in the wall. Saturated flow models are used for heat transfer and fluid flow through the wick. In the wick region, the analysis uses an equilibrium model for heat transfer and a Brinkman-Forchheimer extended Darcy model for fluid flow. Averaged properties weighted with the porosity are used for the wick analysis. The state equation is used in the vapor core to relate density change to the operating pressure. The density change due to pressurization of the vapor core is accounted for in the continuity equation. Vapor flow, temperature and hydrodynamic pressure fields are computed at each time step from coupled continuity/momentum and energy equations in the wick and vapor regions. The mass flow rate at the interface is obtained from the application of kinetic theory. Predictions are made for the magnitude of heat flux at which dryout would occur in a flat heat pipe. The input heat flux and the spacing between the discrete heat sources are studied as parameters. The location in the heat pipe at which dryout is initiated is found to be different from that of the maximum temperature. The location where the maximum capillary pressure head is realized also changes during the transient. Axial conduction through the wall and wick are seen to play a significant role in determining the axial temperature variation.


2011 ◽  
Vol 483 ◽  
pp. 603-606
Author(s):  
Tian Han ◽  
Xiao Wei Liu ◽  
Chao Wang

A kind of flat micro heat pipe with glass fiber wick structure is designed and fabricated. The structure of the wick is presented and also the excellence of the structure is described. For the glass fiber wick, the maximum heat transports is calculated by one-dimensional steady governing equations. Experimental testing is performed for the fabricated micro heat pipe in vacuum. The testing results is presented and analyzed.


Author(s):  
Pramod Chamarthy ◽  
H. Peter J. de Bock ◽  
Boris Russ ◽  
Shakti Chauhan ◽  
Brian Rush ◽  
...  

Heat pipes have been gaining a lot of popularity in electronics cooling applications due to their ease of operation, reliability, and high effective thermal conductivity. An important component of a heat pipe is the wick structure, which transports the condensate from condenser to evaporator. The design of wick structures is complicated by competing requirements to create high capillary driving forces and maintain high permeability. While generating large pore sizes will help achieve high permeability, it will significantly reduce the wick’s capillary performance. This study presents a novel experimental method to simultaneously measure capillary and permeability characteristics of the wick structures using fluorescent visualization. This technique will be used to study the effects of pore size and gravitational force on the flow-related properties of the wick structures. Initial results are presented on wick samples visually characterized from zero to nine g acceleration on a centrifuge. These results will provide a tool to understand the physics involved in transport through porous structures and help in the design of high performance heat pipes.


Author(s):  
Alberto Mucci ◽  
Foster Kwame Kholi ◽  
Man Yeong Ha ◽  
Jason Chetwynd-Chatwin ◽  
June Kee Min

Abstract The Pulsating Heat Pipe (PHP) is a promising device in the family of heat pipes. With no need for a wick, they exhibit a high heat transfer to weight ratio. Moreover, the wickless design removes limits commonly associated with conventional heat pipes, increasing the maximum power transfer per single heat pipe. These peculiarities make it an ideal candidate for many high power applications. Nonetheless, there is though only partial knowledge on the driving mechanism, which restricts prediction accuracy. Most Pulsating Heat Pipe studies rely on experiments to test configurations, while simulations usually depend on semi-empirical correlations or adaptations of reduced theoretical models. Experiments provide detailed data for a particular geometry in lab fixed conditions, but it offers limited flexibility to test alternative configurations. Semi-empirical models use previous experimental data to create non-dimensional formulations. Though approaching an increased set of conditions, correlations apply with reasonable accuracy only to a small range, outside of which the prediction ability progressively falls. High order numerical analysis such as Computational Fluid Dynamics (CFD) modeling could potentially provide full visualization, but due to the complex flow behavior, previous studies used this method only in simple configurations with a small number of turns. The present research will expand the potential of this modeling technique by presenting the CFD analysis of a complex Pulsating Heat Pipe configuration. The importance of this study lies in the fact that this configuration, with a number of turns greater than a critical parameter, shows a reduced sensitivity to gravity and is therefore particularly important for applications where restrictions on installations make the positioning sub-optimal. The research simulates using a CFD commercial software a two-dimensional Pulsating Heat Pipe with sixteen turns. The heat pipe, with a 2 mm internal diameter, is filled with water at 50% of mass. To visualize the oscillation pattern of liquid and vapor slugs and plugs inside the Pulsating Heat Pipe, the model performs a transient analysis on the device. A Volume of Fluid (VOF) solver for multiphase analysis, coupled with the Lee model for evaporation and condensation mass transfer, calculates the interactions between the liquid and the gas phase inside the tube. The study follows the geometric and operational conditions from previous experiments. The analysis regards a Pulsating Heat Pipe operating in a vertical position with the condenser section placed in the upper sector. During the initial operations, the system flow distribution fluctuates between different flow modes as the fluid slugs and plugs structure forms. After stabilizing the heat transfer results well agree with the tested values. Moreover, the increased resolution allows us to fully visualize the internal operation, retrieving additional information on the temperature and ratio of liquid and gas phase along the heat pipe.


2013 ◽  
Vol 135 (11) ◽  
Author(s):  
Lazarus Godson Asirvatham ◽  
Rajesh Nimmagadda ◽  
Somchai Wongwises

The paper presents the enhancement in the operational limits (boiling, entrainment, sonic, viscous and capillary limits) of heat pipes using silver nanoparticles dispersed in de-ionized (DI) water. The tested nanoparticles concentration ranged from 0.003 vol. % to 0.009 vol. % with particle diameter of <100 nm. The nanofluid as working fluid enhances the effective thermal conductivity of heat pipe by 40%, 58%, and 70%, respectively, for volume concentrations of 0.003%, 0.006%, and 0.009%. For an input heat load of 60 W, the adiabatic vapor temperatures of nanofluid based heat pipes are reduced by 9 °C, 18 °C, and 20 °C, when compared with DI water. This reduction in the operating temperature enhances the thermophysical properties of working fluid and gives a change in the various operational limits of heat pipes. The use of silver nanoparticles with 0.009 vol. % concentration increases the capillary limit value of heat pipe by 54% when compared with DI water. This in turn improves the performance and operating range of the heat pipe.


1990 ◽  
Vol 112 (3) ◽  
pp. 602-607 ◽  
Author(s):  
B. R. Babin ◽  
G. P. Peterson

A computer model was developed to aid in the design of a flexible bellows heat pipe for cooling small discrete heat sources or arrays of small heat sources. This model was used to evaluate the operational characteristics and performance limitations of these heat pipes and to formulate and optimize a series of conceptual designs. Three flexible bellows heat pipes approximately 40 mm in length and 6 mm in diameter were constructed and tested using three different wick configurations. The test pipes were found to be boiling limited over most of the operating temperature range tested. Heat fluxes in excess of 200 W/cm2 were obtained and thermal resistance values of less than 0.7 °C/W were measured. Although the computer model slightly underestimated the experimentally determined transport limit for one of the wicking configurations, the remaining transport predictions were consistently within 8 percent of the experimental values.


Author(s):  
Weilin Zhao ◽  
Jun Xu ◽  
Jinkai Li

Abstract The graphene oxide-deionized water (GO-DW) and graphene oxide-ethylence glycol (GO-EG) nanofluids were synthesized. The better suspension of nanofluids was achieved. The thermal conductivity of both nanofluids was analyzed. It indicates that GO nanoparticles can strengthen the thermal conductivity of DW base fluids by 22.6%–61.7% and EG base fluids by 15.3%–32.8%. Four copper heat pipes charged with GO-DW and GO-EG nanofluids as well as DW and EG base fluids were experimentally researched, it is discovered that the addition of GO nonoparticles in heat pipe can elevate the condenser wall temperature and reduce the temperature difference. Future analysis finds that, with respect to DW and EG fluids heat pipe, the thermal resistances of GO-DW and GO-EG nanofluids heat pipe are respectively decreased 42.6–52.4% and 31.9%–38.4% for air cooling, and 15.5–16.7% and 11.5%–18.9% for water cooling at condenser section. Besides, the wick structure of GO-DW nanofluids heat pipe was examined by Scanning Electron Microscope, and the effective thermal conductivity of fluid-wick combination was evaluated. The outcomes demonstrate that the evaporator wick surface contains about 0375–1.24μm coating film of GO nanoparticles. Assumed the coating film is 0.75μm, the effective thermal conductivity of fluid-wick combination is respectively enhanced by 66.92 % for GO-DW nonofluids heat pipe and 37.32% for GO-EG nonofluids heat pipe at 70 °C.