Entrainment Limitations in Thermosyphons and Heat Pipes

1991 ◽  
Vol 113 (3) ◽  
pp. 147-153 ◽  
Author(s):  
G. P. Peterson ◽  
B. K. Bage

The isothermal characteristics and high effective thermal conductivity of heat pipes and thermosyphons make them particularly useful in air to air and process to air heat recovery systems. Although previous investigations have developed successful techniques for predicting many of the transport limitations, entrainment remains the least understood. Current entrainment modeling techniques have resulted in a large range in the predicted axial heat flux required for the onset of entrainment. Included here is a review of the present analytical methods used to predict the liquid entrainment as a function of the pipe’s physical parameters and working fluid properties, for both thermosyphons and heat pipes. The results of the models are compared with existing experimental data in an effort to determine the accuracy of the predictive techniques. Using a sample copper/water thermosyphon and a similar screen wicked heat pipe, comparisons of the experimental entrainment limit and those predicted by seven thermosyphon and four heat pipe models were made. The results of this comparison can provide insight for designers developing heat pipe exchangers and will provide a basis for further understanding the phenomena which govern this limit.

2021 ◽  
Vol 2119 (1) ◽  
pp. 012088
Author(s):  
A. A. Litvintceva ◽  
N. I. Volkov ◽  
N. I. Vorogushina ◽  
V. A. Moskovskikh ◽  
V. V. Cheverda

Abstract Heat pipes are a good solution for temperature stabilization, for example, of microelectronics, because these kinds of systems are without any moving parts. Experimental research of the effect of operating parameters on the heat transfer in a cylindrical heat pipe has been conducted. The effect of the working fluid properties and the porous layer thickness on the heat flux and temperature difference in the heat pipe has been investigated. The temperature field of the heat pipe has been investigated using the IR-camera and K-type thermocouples. The data obtained by IR-camera and K-type thermocouples have been compared. It is demonstrated the power transferred from the evaporator to the condenser is a linear function of the temperature difference between them.


1972 ◽  
Vol 94 (2) ◽  
pp. 155-162 ◽  
Author(s):  
D. K. Edwards ◽  
B. D. Marcus

An analysis is presented of axially conducting gas-controlled heat pipes leading to a predictive capability for the heat and mass transfer along the heat pipe. In addition, experimental results are presented which verify the analysis, and computational results are presented which show the relative influence of various parameters which affect the system behavior. In particular it was found that axial heat conduction is of much greater importance than axial mass diffusion in establishing the wall temperature profiles and condenser heat-transfer characteristics of gas-loaded heat pipes. However, mass diffusion and, consequently, the choice of working fluid and control gas are of considerable importance in establishing the “diffusion freezeout rate” if the potential exists for freezing of vapor which penetrates the gas-blocked portion of the condenser. It is believed that the analysis and associated computer program are useful tools for designing gas-loaded heat pipes.


2018 ◽  
Vol 67 ◽  
pp. 02056
Author(s):  
Imansyah Ibnu Hakim ◽  
Nandy Putra ◽  
Adam Prihananda Marda ◽  
Muhammad Alvin Alvaro ◽  
Adi Winarta

Heating, Ventilation, and Air Conditioning (HVAC) system in hospital's clean room is required to continue working for 24 hours to provide the ideal air quality for the activities therein. This causes a huge amount of energy consumption in hospital buildings itself. This study aims to determine the effectiveness and heat recovery of Heat Pipe Heat Exchanger (HPHE). The HPHE used in this study consisted of 12 heat pipes per module, in which the line was arranged staggered. The number of the module is varied 3 times, which are 1, 2, and 3 modules. The heat pipe is made of copper and contains working fluid in the form of water with 50% filling ratio. HPHE equipped with fins to expand the contact surface with airflow. Each variation of the number of modules is tested on the HVAC system model of the clean room. In the evaporator inlet, air flowing to the variation of temperature: 28, 30, 35, and 40°C, and at speeds of 1.5, 2.0, 2.5 m/s. The use of HPHE can recover heat as much as 1654.72 kJ/h. The highest effectiveness of this HPHE is 48.729%, was obtained when using three modules, air temperature inlet evaporator (Te,i) = 35°C, and airspeed of inlet 1.5 m/s.


1998 ◽  
Vol 120 (4) ◽  
pp. 1064-1071 ◽  
Author(s):  
J. M. Ha ◽  
G. P. Peterson

The original analytical model for predicting the maximum heat transport capacity in micro heat pipes, as developed by Cotter, has been re-evaluated in light of the currently available experimental data. As is the case for most models, the original model assumed a fixed evaporator region and while it yields trends that are consistent with the experimental results, it significantly overpredicts the maximum heat transport capacity. In an effort to provide a more accurate predictive tool, a semi-empirical correlation has been developed. This modified model incorporates the effects of the temporal intrusion of the evaporating region into the adiabatic section of the heat pipe, which occurs as the heat pipe approaches dryout conditions. In so doing, the current model provides a more realistic picture of the actual physical situation. In addition to incorporating these effects, Cotter’s original expression for the liquid flow shape factor has been modified. These modifications are then incorporated into the original model and the results compared with the available experimental data. The results of this comparison indicate that the new semiempirical model significantly improves the correlation between the experimental and predicted results and more accurately represents the actual physical behavior of these devices.


Author(s):  
Michael Ozeh ◽  
A. G. Agwu Nnanna

Powering small electronics like mobile devices off-grid has remained a challenge; hence, there exists a need for an alternate source of powering these devices. This paper examines the efficacy of a novel nanoparticle-immobilized polyethylene wick in maintaining sufficient thermal gradient across a thermoelectric generator to power these devices with energy from waste heat. The work examines several other heat exchangers including heat pipes and loop heat pipe setups. The experimental evidence reveals that the nanoparticle-immobilized polyethylene wick is capable of generating sufficient thermal potential resulting in 5V, which is the minimum voltage required to power small mobile devices. In the opinion of the authors, this is the first ever recorded account of utilizing waste heat to generate enough voltage to power a mobile device. Experiment demonstrated that the nanoparticle-immobilized polyethylene wick showed over 40% thermoelectric voltage generation increment over a plain polyethylene wick and a metal wick in a loop heat pipe setup.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


2020 ◽  
Vol 21 (3) ◽  
pp. 309
Author(s):  
Maryam Fallah Abbasi ◽  
Hossein Shokouhmand ◽  
Morteza Khayat

Electronic industries have always been trying to improve the efficiency of electronic devices with small dimensions through thermal management of this equipment, thus increasing the use of small thermal sinks. In this study micro heat pipes with triangular and square cross sections have been manufactured and tested. One of the main objectives is to obtain an understanding of micro heat pipes and their role in energy transmission with electrical double layer (EDL). Micro heat pipes are highly efficient heat transfer devices, which use the continuous evaporation/condensation of a suitable working fluid for two-phase heat transport in a closed system. Since the latent heat of vaporization is very large, heat pipes transport heat at small temperature difference, with high rates. Because of variety of advantage features these devices have found a number of applications both in space and terrestrial technologies. The theory of operation micro heat pipes with EDL is described and the micro heat pipe has been studied. The temperature distribution have achieved through five thermocouples installed on the body. Water and different solution mixture of water and ethanol have used to investigate effect of the electric double layer heat transfer. It was noticed that the electric double layer of ionized fluid has caused reduction of heat transfer.


2014 ◽  
Vol 1082 ◽  
pp. 309-314 ◽  
Author(s):  
Diogo L.F. Santos ◽  
Larissa S. Marquardt ◽  
Paulo H.D. Santos ◽  
Thiago Antonini Alves

This work presents a theoretical and experimental analysis of a heat exchanger assisted by five heat pipes made of copper with a metallic mesh 100 of stainless steel which was used as capillary structure. All heat pipes used water as the working fluid and were designed based on the capillary limit model. The heat pipes were developed and tested under heat loads varying from 20 to 50 W before application into the heat exchanger. The theoretical and experimental results were compared and all heat pipes worked satisfactorily. Thereafter, it is presented the development of heat pipe heat exchanger which was tested under heat loads varying from 100 to 250 W. The highest temperature measured on the external surface of the heat pipes was 90 oC and the heat exchanger thermal efficiency varied from 74 to 80%. It is showed that the use of a stainless steel mesh as a porous wick was proved to work successfully in heat pipes.


Volume 3 ◽  
2004 ◽  
Author(s):  
R. Kempers ◽  
A. Robinson ◽  
C. Ching ◽  
D. Ewing

A study was performed to experimentally characterize the effect of fluid loading on the heat transport performance of wicked heat pipes. In particular, experiments were performed to characterize the performance of heat pipes with insufficient fluid to saturate the wick and excess fluid for a variety of orientations. It was found that excess working fluid in the heat pipe increased the thermal resistance of the heat pipe, but increased maximum heat flux through the pipe in a horizontal orientation. The thermal performance of the heat pipe was reduced when the amount of working fluid was less than required to saturate the wick, but the maximum heat flux through the heat pipe was significantly reduced at all orientations. It was also found in this case the performance of this heat pipe deteriorated once dry-out occurred.


Author(s):  
Garrett A. Glover ◽  
Yongguo Chen ◽  
Annie Luo ◽  
Herman Chu

The current work is a survey of applied applications of passive 2-phase technologies, such as heat pipe and vapor chamber, in heat sink designs with thin base for electronic cooling. The latest improvements of the technologies and manufacturing processes allow achievable heat sink base thickness of 3 mm as compared to around 5 mm previously. The key technical challenge has been on maintaining structural integrity for adequate hollow space for the working fluid vapor in order to retain high performance while reducing the thickness of the overall vapor chamber or flattened heat pipe. Several designs of thin vapor chamber base heat sink and embedded heat pipe heat sink from different vendors are presented for a moderate power density application of a 60 W, 13.2 mm square heat source. Numerous works have been published by both academia and commercial applications in studying the fundamental science of passive 2-phase flow technologies; their performance has been compared to solid materials, like aluminum and copper. These works have established the merits of using heat pipes and vapor chambers in electronic cooling. The intent of this paper is to provide a methodical approach to help to accelerate the process in evaluating the arrays of different commercial designs of these devices in our product design cycle. In this paper, the trade-offs between the different types of technologies are discussed for parameters such as performance advantages, physical attributes, and some cost considerations. This is a bake-off evaluation of the complete heat sink solutions from the various vendors and not a fundamental research of vapor chambers and heat pipes — for that, it is best left to the vendors and universities.


Sign in / Sign up

Export Citation Format

Share Document