scholarly journals In Vitro Fatigue Failure of Cemented Acetabular Replacements: A Hip Simulator Study

2008 ◽  
Vol 130 (2) ◽  
Author(s):  
N. P. Zant ◽  
P. Heaton-Adegbile ◽  
J. G. Hussell ◽  
J. Tong

Although hip simulators for in vitro wear testing of prosthetic materials used in total hip arthroplasty (THA) have been available for a number of years, similar equipment has yet to appear for endurance testing of fixation in cemented THA, despite considerable evidence of late aseptic loosening as one of the most significant failure mechanisms in this type of replacements. An in vitro study of fatigue behavior in cemented acetabular replacements has been carried out, utilizing a newly developed hip simulator. The machine was designed to simulate the direction and the magnitude of the hip contact force under typical physiological loading conditions, including normal walking and stair climbing, as reported by Bergmann et al. (2001, Hip 98, Freie Universitaet, Berlin). A 3D finite element analysis has been carried out to validate the function of the hip simulator and to evaluate the effects of boundary conditions and geometry of the specimen on the stress distribution in the cement mantle. Bovine pelvic bones were implanted with a Charnley cup, using standard manual cementing techniques. Experiments were carried out under normal walking and descending stairs loading conditions with selected load levels from a body weight of 75–125kg. Periodically, the samples were removed from the test rigs to allow CT scanning for the purpose of monitoring damage development in the cement fixation. The hip simulator was found to be satisfactory in reproducing the hip contact force during normal walking and stair climbing, as reported by Bergmann et al. Finite element analysis shows that the stress distributions in the cement mantle and at the bone-cement interface are largely unaffected by the geometry and the boundary conditions of the model. Three samples were tested up to 17×106cycles and sectioned post-testing for microscopic studies. Debonding at the bone-cement interface of various degrees in the posterior-superior quadrant was revealed in these samples, and the location of the failures corresponds to the highest stressed region from the finite-element analysis. Preliminary experimental results from a newly developed hip simulator seem to suggest that debonding at the bone-cement interface is the main failure mechanism in cemented acetabular replacements, and descending stairs seem to be more detrimental than normal walking or ascending stairs with regard to fatigue integrity of cement fixation.

1996 ◽  
Vol 118 (3) ◽  
pp. 399-404 ◽  
Author(s):  
T. L Norman ◽  
V. C. Saligrama ◽  
K. T. Hustosky ◽  
T. A. Gruen ◽  
J. D. Blaha

A tapered femoral total hip stem with a debonded stem-cement interface and an unsupported distal tip subjected to constant axial load was evaluated using two-dimensional (2D) axisymmetric finite element analysis. The analysis was performed to test if the mechanical condition suggest that a “taper-lock” with a debonded viscoelastic bone cement might be an alternative approach to cement fixation of stem type cemented hip prosthesis. Effect of stem-cement interface conditions (bonded, debonded with and without friction) and viscoelastic response (creep and relaxation) of acrylic bone cement on cement mantle stresses and axial displacement of the stem was also investigated. Stem debonding with friction increased maximum cement von Mises stress by approximately 50 percent when compared to the bonded stem. Of the stress components in the cement mantle, radial stresses were compressive and hoop stresses were tensile and were indicative of mechanical taper-lock. Cement mantle stress, creep and stress relaxation and stem displacement increased with increasing load level and with decreasing stem-cement interface friction. Stress relaxation occur predominately in tensile hoop stress and decreased from 1 to 46 percent over the conditions considered. Stem displacement due to cement mantle creep ranged from 614 μm to 1.3 μm in 24 hours depending upon interface conditions and load level.


2014 ◽  
Vol 2014 ◽  
pp. 1-17 ◽  
Author(s):  
Azim Ataollahi Oshkour ◽  
Hossein Talebi ◽  
Seyed Farid Seyed Shirazi ◽  
Mehdi Bayat ◽  
Yat Huang Yau ◽  
...  

This study is focused on finite element analysis of a model comprising femur into which a femoral component of a total hip replacement was implanted. The considered prosthesis is fabricated from a functionally graded material (FGM) comprising a layer of a titanium alloy bonded to a layer of hydroxyapatite. The elastic modulus of the FGM was adjusted in the radial, longitudinal, and longitudinal-radial directions by altering the volume fraction gradient exponent. Four cases were studied, involving two different methods of anchoring the prosthesis to the spongy bone and two cases of applied loading. The results revealed that the FG prostheses provoked more SED to the bone. The FG prostheses carried less stress, while more stress was induced to the bone and cement. Meanwhile, less shear interface stress was stimulated to the prosthesis-bone interface in the noncemented FG prostheses. The cement-bone interface carried more stress compared to the prosthesis-cement interface. Stair climbing induced more harmful effects to the implanted femur components compared to the normal walking by causing more stress. Therefore, stress shielding, developed stresses, and interface stresses in the THR components could be adjusted through the controlling stiffness of the FG prosthesis by managing volume fraction gradient exponent.


Author(s):  
Masaru Higa ◽  
Ikuya Nishimura ◽  
Kazuhiro Matsuda ◽  
Hiromasa Tanino ◽  
Yoshinori Mitamura

Though Total Hip Arthroplasty (THA) is being performed with greater frequency every year for patients with endstage arthritis of hip, mechanical fatigue of bone cement leading to damage accumulation is implicated in the loosening of cemented hip components. This fatigue failure of bone cement has been reported to be the result of high tensile and shear stresses at the bone cement. The aim of this study is to design the optimum shape of femoral component of a THA that minimizes the peak stress value of maximum principal stress at the bone cement and to validate the FEM results by comparing numerical stress with experimental ones. The p-version three-dimensional Finite Element Method (FEM) combined with an optimization procedure was used to perform the shape optimization. Moreover the strain in the cement mantle surrounding the cemented femoral component of a THA was measured in vitro using strain gauges embedded within the cement mantle adjacent to the developed femoral stem to validate the optimization results of FEM.


2019 ◽  
Vol 63 (3) ◽  
pp. 303-308 ◽  
Author(s):  
Toshiki Yamazaki ◽  
Natsuko Murakami ◽  
Shizuka Suzuki ◽  
Kazuyuki Handa ◽  
Masaru Yatabe ◽  
...  