The Energy Impact of Air Leakage Through Insulated Walls

1995 ◽  
Vol 117 (3) ◽  
pp. 167-172 ◽  
Author(s):  
S. Bhattacharyya ◽  
D. E. Claridge

Infiltration is customarily assumed to increase the heating and cooling load of a building by an amount equal to the mass flow rate of the infiltration times the enthalpy difference between the inside and outside air—with the latent portion of the enthalpy difference sometimes neglected. An experimental and analytical investigation has been conducted on the actual energy impact of air leakage on a well-characterized insulated stud-cavity wall specimen. Calorimetric measurements conducted on the specimen with measured amounts of air leakage introduced under a variety of controlled conditions and configurations verify earlier test cell measurements showing that infiltration heat exchange can lead to a much smaller change in the energy load due to infiltration than is customarily calculated and show the dependence of infiltration heat exchange on flow rate and path length. An analytical model based on fundamental heat and mass transfer principles has been developed and the predicted values of Infiltration Heat Exchange Effectiveness, ε, as a function of air flow rates and effective path length for five stud-cavity wall specimen test configurations were consistent with the experimental results. Significant experimental results include: (i) ε values in the 0.16–0.7 range in the stud-cavity and (ii) ε values of 0.16 to 0.34 for air exiting the stud-cavity directly across from the entry. These results indicate that significant heat recovery is probable for most leakage occurring through insulated stud cavities.

1990 ◽  
Vol 112 (2) ◽  
pp. 132-139 ◽  
Author(s):  
David E. Claridge ◽  
Souvik Bhattacharyya

Infiltration is customarily assumed to increase the heating and cooling load of a building by an amount equal to the mass flow rate of the infiltration times the enthalpy difference between the inside and outside air—with the latent portion of the enthalpy difference sometimes neglected. Calorimetric measurements conducted on a small test cell with measured amounts of infiltration introduced under a variety of conditions show convincingly that infiltration can lead to a much smaller change in the energy load than is customarily calculated; changes as small as 20 percent of the calculated value have been measured in the cell. The data also suggest that the phenomenon occurs in full-sized houses as well. Infiltration Heat Exchange Effectiveness (IHEE), ε, is introduced as a measure of the effectiveness of a building in “recovering” heat otherwise lost (or gained) due to infiltration. Measurements show that ε increases as: (a) flow rate decreases; (b) flow path length increases; (c) hole/crack size decreases. There is a clear correlation between large values of ε and large values of the exponent, n, so fan pressurization results may be useful in predicting ε for buildings.


2021 ◽  
Vol 18 (3) ◽  
pp. 172988142110264
Author(s):  
Jiqing Chen ◽  
Chenzhi Tan ◽  
Rongxian Mo ◽  
Hongdu Zhang ◽  
Ganwei Cai ◽  
...  

Among the shortcomings of the A* algorithm, for example, there are many search nodes in path planning, and the calculation time is long. This article proposes a three-neighbor search A* algorithm combined with artificial potential fields to optimize the path planning problem of mobile robots. The algorithm integrates and improves the partial artificial potential field and the A* algorithm to address irregular obstacles in the forward direction. The artificial potential field guides the mobile robot to move forward quickly. The A* algorithm of the three-neighbor search method performs accurate obstacle avoidance. The current pose vector of the mobile robot is constructed during obstacle avoidance, the search range is narrowed to less than three neighbors, and repeated searches are avoided. In the matrix laboratory environment, grid maps with different obstacle ratios are compared with the A* algorithm. The experimental results show that the proposed improved algorithm avoids concave obstacle traps and shortens the path length, thus reducing the search time and the number of search nodes. The average path length is shortened by 5.58%, the path search time is shortened by 77.05%, and the number of path nodes is reduced by 88.85%. The experimental results fully show that the improved A* algorithm is effective and feasible and can provide optimal results.


1993 ◽  
Vol 16 (2) ◽  
pp. 63-70 ◽  
Author(s):  
N.A. Hoenich ◽  
P.T. Smirthwaite ◽  
C. Woffindin ◽  
P. Lancaster ◽  
T.H. Frost ◽  
...  

Recirculation is an important factor in single needle dialysis and, if high, can compromise treatment efficiency. To provide information regarding recirculation characteristics of access devices used in single needle dialysis, we have developed a new technique to characterise recirculation and have used this to measure the recirculation of a Terumo 15G fistula needle and a VasCath SC2300 single lumen catheter. The experimentally obtained results agreed well with those established clinically (8.5 ± 2.4% and 18.4 ± 3.4%). The experimental results have also demonstrated a dependence on access type, pump speeds and fistula flow rate. A comparison of experimental data with theoretical predictions showed that the latter exceeded those measured with the largest contribution being due to the experimental fistula.


Author(s):  
Ignacio Carvajal-Mariscal ◽  
Florencio Sanchez-Silva ◽  
Georgiy Polupan

In this work the heat transfer and pressure drop experimental results obtained in a two step finned tube bank with conical fins are presented. The tube bank had an equilateral triangle array composed of nine finned tubes with conical fins inclined 45 degrees in respect with the tube axis. The heat exchange external area of a single tube is approximately 0.07 m2. All necessary thermal parameters, inlet/outlet temperatures, mass flows, for the heat balance in the tube bank were determined for different air velocities, Re = 3400–18400, and one constant thermal charge provided by a hot water flow with a temperature of 80 °C. As a result, the correlations for the heat transfer and pressure drop calculation were obtained. The experimental results were compared against the analytical results for a tube bank with annular fins with the same heat exchange area. It was found that the proposed tube bank using finned tubes with conical fins shows an increment of heat transfer up to 58%.


Author(s):  
Yun-Hao Peng ◽  
Dai-Hua Wang ◽  
Lian-Kai Tang

Parametric simulation of multi-chamber piezoelectric pump proposed by authors shows that its flow rate is positively correlated with chamber compression ratio when height of chamber wall is not less than central deflection of circular piezoelectric unimorph actuator (CPUA). Therefore, in this paper, principle and structure of multi-chamber piezoelectric pump with novel CPUAs with three-layer structure are proposed and realized, so as to improve its chamber compression ratio, and then improve its flow rate. Its processing technology compatible with PCB processing technology is studied and its flow rate model is established. Central deflection of CPUA with three-layer structure and the flow rate characteristics are tested. Experimental results show that when the central deflection of CPUA with three-layer structure reaches the maximum value of 106.8 μm, the chamber compression ratio and flow rate of multi-chamber piezoelectric pump reach the maximum value of 50% and 3.11 mL/min, respectively. The maximum flow rate is increased by 622% compared to unimproved pump. By comparing experimental results with numerical and finite element simulation results, the realized multi-chamber piezoelectric pump has large flow rate and the established flow rate model can predict its flow rate.


1979 ◽  
Vol 46 (2) ◽  
pp. 465-468 ◽  
Author(s):  
V. K. Kapur ◽  
J. S. Yadav

In the present analysis, the interactions of thermal effects and velocity slip on the performance of externally pressurized porous incompressible gas thrust bearing have been studied. Numerical results for load capacity, mass flow rate, and static stiffness have been obtained and their behavior is illustrated in figures. The results for slip as well as no-slip condition have also been compared with the experimental results of Gargiulo and Gilmour [7].


Author(s):  
S. M. Miner ◽  
R. D. Flack ◽  
P. E. Allaire

Two dimensional potential flow was used to determine the velocity field within a laboratory centrifugal pump. In particular, the finite element technique was used to model the impeller and volute simultaneously. The rotation of the impeller within the volute was simulated by using steady state solutions with the impeller in 10 different angular orientations. This allowed the interaction between the impeller and the volute to develop naturally as a result of the solution. The results for the complete pump model showed that there are circumferential asymmetries in the velocity field, even at the design flow rate. Differences in the relative velocity components were as large as 0.12 m/sec for the radial component and 0.38 m/sec for the tangential component, at the impeller exit. The magnitude of these variations was roughly 25% of the magnitude of the average radial and tangential velocities at the impeller exit. These asymmetries were even more pronounced at off design flow rates. The velocity field was also used to determine the location of the tongue stagnation point and to calculate the slip within the impeller. The stagnation point moved from the discharge side of the tongue to the impeller side of the tongue, as the flow rate increased from below design flow to above design flow. At design flow, values of slip ranged from 0.96 to 0.71, from impeller inlet to impeller exit. For all three types of data (velocity profiles, stagnation point location, and slip factor) comparison was made to laser velocimeter data, taken for the same pump. At the design flow, the computational and experimental results agreed to within 17% for the velocity magnitude, and 2° for the flow angle. The stagnation point locations coincided for the computational and experimental results, and the values for slip agreed to within 10%.


Designs ◽  
2021 ◽  
Vol 5 (4) ◽  
pp. 58
Author(s):  
David Denkenberger ◽  
Joshua M. Pearce ◽  
Michael Brandemuehl ◽  
Mitchell Alverts ◽  
John Zhai

A finite difference model of a heat exchanger (HX) considered maldistribution, axial conduction, heat leak, and the edge effect, all of which are needed to model a high effectiveness HX. An HX prototype was developed, and channel height data were obtained using a computerized tomography (CT) scan from previous work along with experimental results. This study used the core geometry data to model results with the finite difference model, and compared the modeled and experimental results to help improve the expanded microchannel HX (EMHX) prototype design. The root mean square (RMS) error was 3.8%. Manifold geometries were not put into the model because the data were not available, so impacts of the manifold were investigated by varying the temperature conditions at the inlet and exit of the core. Previous studies have not considered the influence of heat transfer in the manifold on the HX effectiveness when maldistribution is present. With no flow maldistribution, manifold heat transfer increases overall effectiveness roughly as would be expected by the greater heat transfer area in the manifolds. Manifold heat transfer coupled with flow maldistribution for the prototype, however, causes a decrease in the effectiveness at high flow rate, and an increase in effectiveness at low flow rate.


Author(s):  
Ioan DROCAS ◽  
Ovidiu MARIAN ◽  
Ovidiu RANTA ◽  
Sorin STANILA ◽  
Mircea MUNTEAN ◽  
...  

Reduced environmental pollution and ensuring fair treatment in crops can be achieved through constructive and functional upgrading of spraying machines. The paper studies the variation of the nozzle flow, liquid pressure and uniformity of distribution for the EEP-600M machine. The experimental results have shown changes in the functional parameters of the nozzle (flow and pressure) depending on the nozzle position on the ramp section. The way of connecting the hoses leading the solution to the ramp and the number of nozzles per segment can influence the uniformity of distribution of the solution.


Author(s):  
G. Mimmi

Abstract In a previous paper the author proposed a method to reduce the periodic variation in flow rate for an external gear pump. To verify the experimental results, a series of experimental tests on a expressly realized gear pump, was carried out. The pump was equipped with relieving grooves milled into the side plates. The tests were done on a closed piping specifically realized and equipped for measuring the instantaneous flow rate of the fluid through a wedge-shaped hot film probe.


Sign in / Sign up

Export Citation Format

Share Document