Numerical Simulation of Cross-Flow-Induced Fluidelastic Vibration of Tube Arrays and Comparison With Experimental Results

1995 ◽  
Vol 117 (1) ◽  
pp. 31-39 ◽  
Author(s):  
F. L. Eisinger ◽  
M. S. M. Rao ◽  
D. A. Steininger ◽  
K. H. Haslinger

Tube arrays exposed to air, gas or liquid cross-flow can vibrate due to vortex-shedding, turbulence, or fluidelastic instability. The major emphasis of this paper is on the phenomenon of fluidelastic instability (or fluidelastic vibration). A numerical model is applied to the simulation of fluidelastic vibration of representative tubes in a tube bundle, based on S. S. Chen’s unsteady flow theory. The results are validated against published data based on linear cases. The model is then applied to a nonlinear structure of a U-bend tube bundle with clearances at supports, and the computed results compared to those obtained by experimental testing. The numerical studies were performed using the ABAQUS-EPGEN finite element code using a special subroutine incorporating fluidelastic forces. It is shown that the results of both the linear and nonlinear modeling are in good agreement with experimental data.

Author(s):  
Joaquin E. Moran ◽  
David S. Weaver

An experimental study was conducted to investigate damping and fluidelastic instability in tube arrays subjected to two-phase cross-flow. The purpose of this research was to improve our understanding of these phenomena and how they are affected by void fraction and flow regime. The working fluid used was Freon 11, which better models steam-water than air-water mixtures in terms of vapour-liquid mass ratio as well as permitting phase changes due to pressure fluctuations. The damping measurements were obtained by “plucking” the monitored tube from outside the test section using electromagnets. An exponential function was fitted to the tube decay trace, producing consistent damping measurements and minimizing the effect of frequency shifting due to fluid added mass fluctuations. The void fraction was measured using a gamma densitometer, introducing an improvement over the Homogeneous Equilibrium Model (HEM) in terms of density and velocity predictions. It was found that the Capillary number, when combined with the two-phase damping ratio (interfacial damping), shows a well defined behaviour depending on the flow regime. This observation can be used to develop a better methodology to normalize damping results. The fluidelastic results agree with previously presented data when analyzed using the HEM and the half-power bandwidth method. The interfacial velocity is suggested for fluidelastic studies due to its capability for collapsing the fluidelastic data. The interfacial damping was introduced as a tool to include the effects of flow regime into the stability maps.


Author(s):  
Tomomichi Nakamura ◽  
Shinichiro Hagiwara ◽  
Joji Yamada ◽  
Kenji Usuki

In-flow instability of tube arrays is a recent major issue in heat exchanger design since the event at a nuclear power plant in California [1]. In our previous tests [2], the effect of the pitch-to-diameter ratio on fluidelastic instability in triangular arrays is reported. This is one of the present major issues in the nuclear industry. However, tube arrays in some heat exchangers are arranged as a square array configuration. Then, it is important to study the in-flow instability on the case of square arrays. The in-flow fluidelastic instability of square arrays is investigated in this report. It was easy to observe the in-flow instability of triangular arrays, but not for square arrays. The pitch-to-diameter ratio, P/D, is changed from 1.2 to 1.5. In-flow fluidelastic instability was not observed in the in-flow direction. Contrarily, the transverse instability is observed in all cases including the case of a single flexible cylinder. The test results are finally reported including the comparison with the triangular arrays.


Author(s):  
H. Omar ◽  
M. Hassan ◽  
A. Gerber

This study investigates the unsteady flow and the resulting fluidelastic forces in a tube bundle. Numerical simulations are presented for normal triangle tube arrays with pitch-to-diameter (P/d) ratios of 1.35, 1.75, and 2.5 utilizing a 2-dimensional model. In this model a single tube was forced to oscillate within an otherwise rigid array. Fluid forces acting on the oscillating tube and the surrounding tubes were estimated. The predicted forces were utilized to calculate fluid force coefficients for all tubes. The numerical model solves the Reynolds-Average Navier-Stokes (RANS) equations for unsteady turbulent flow, and is cast in an Arbitrary Lagrangian-Eulerian (ALE) form to handle mesh the motion associated with a moving boundary. The fluidelastic instability (FEI) was predicted for both single and fully flexible tube arrays over a mass damping parameter (MDP) range of 0.1 to 200. The effect of the P/d ratio and the Reynolds number on the FEI threshold was investigated in this work.


1995 ◽  
Vol 117 (4) ◽  
pp. 321-329 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor ◽  
J. H. Jong ◽  
I. G. Currie

Two-phase cross-flow exists in many shell-and-tube heat exchangers. The U-bend region of nuclear steam generators is a prime example. Testing in two-phase flow simulated by air-water provides useful results inexpensively. However, two-phase flow parameters, in particular surface tension and density ratio, are considerably different in air-water than in steam-water. A reasonable compromise is testing in liquid-vapor Freon, which is much closer to steam-water while much simpler experimentally. This paper presents the first results of a series of tests on the vibration behavior of tube bundles subjected to two-phase Freon cross-flow. A rotated triangular tube bundle of tube-to-diameter ratio of 1.5 was tested over a broad range of void fractions and mass fluxes. Fluidelastic instability, random turbulence excitation, and damping were investigated. Well-defined fluidelastic instabilities were observed in continuous two-phase flow regimes. However, intermittent two-phase flow regimes had a dramatic effect on fluidelastic instability. Generally, random turbulence excitation forces are much lower in Freon than in air-water. Damping is very dependent on void fraction, as expected.


Author(s):  
Paul Feenstra ◽  
Teguewinde Sawadogo ◽  
Bruce Smith ◽  
Victor Janzen ◽  
Helen Cothron

The tubes in the U-bend region of a recirculating type of nuclear steam generator are subjected to cross-flow of a two-phase mixture of steam and water. There is a concern that these tubes may experience flow-induced vibration, including the damaging effects of fluidelastic instability. This paper presents an update and results from a series of flow-induced vibration experiments performed by Canadian Nuclear Laboratories for the Electric Power Research Institute (EPRI) using the Multi-Span U-Bend test rig. In the present experiments, the main focus was to investigate fluidelastic instability of the U-tubes subjected to a cross-flow of air. The tube bundle is made of 22 U-tubes of 0.5 in (12.7 mm) diameter, arranged in a rotated triangular configuration with a pitch-over-diameter ratio of 1.5. The test rig could be equipped with variable clearance flat bar supports at two different locations to investigate a variety of tube and support configurations. The primary purpose of the overall project is to study the effect of flat bar supports on ‘in plane’ (‘streamwise’) instability in a U-tube bundle with realistic tube-to-support clearances or preloads, and eventually in two-phase flow conditions. Initially, the test rig was designed for tests in air-flow using an industrial air blower. Tests with two-phase Freon refrigerant (R-134a) will follow. This paper describes the test rig, experimental setup, and the challenges presented by simulating an accurate representation of current steam generator designs. Results from the first series of tests in air flow are described.


Author(s):  
A. Khalvatti ◽  
N. W. Mureithi ◽  
M. J. Pettigrew

In the operation of shell-and-tube heat exchangers, vibration of the tubes can be induced by fluid flowing over the tube array in cross flow. The region of concern in Steam Generators (SG) is the upper most U-bend region where the flow crosses a large number of tubes which can cause significant hydraulic resistance. This hydraulic resistance forces the flow to change direction. From a fluidelastic instability point of view, the tube bundle is excited by oblique cross flow. The purpose of this paper is to examine the instability phenomena in a rotated triangular tube bundle subjected to oblique single phase cross flow. In this present work tests are conducted in a wind tunnel on a rotated triangle tube array. Fluidelastic instability results are in agreement with what was expected. The results show that fluidelastic instability is strongly dependent on the angle of attack. The results also show that, generally, the elimination of bundle flexibility in the direction transverse to the flow, greatly affects the stability behavior of the array.


2005 ◽  
Vol 127 (1) ◽  
pp. 84-91 ◽  
Author(s):  
V. P. Janzen ◽  
E. G. Hagberg ◽  
M. J. Pettigrew ◽  
C. E. Taylor

The dynamic response of U-tubes to two-phase cross-flow has been studied in tests involving a simplified U-tube bundle with a set of flat-bar supports at the apex, subjected to air–water cross-flow over the mid-span region. Tube vibration and the interaction between tubes and supports were measured over a wide range of void fractions and flow rates, for three different tube-to-support clearances. The vibration properties and tube-to-support work-rates could be characterized in terms of the relative influence of fluidelastic instability and random-turbulence excitation. For the first time, in a U-bend tube bundle with liquid or two-phase flow, fluidelastic instability was observed both in the out-of-plane and in the in-plane direction. This raises the possibility of higher-than-expected tube-to-support work-rates for U-tubes restrained by flat bars, particularly if fluidelastic instability, random turbulence and loose supports combine adversely.


Author(s):  
T. F. Joly ◽  
N. W. Mureithi ◽  
M. J. Pettigrew

Tests were done to study the effect of angle of attack on the fluidelastic instability of a fully flexible tube bundle subjected to two-phase (Air-Water) cross-flow. A test array having nineteen flexible tubes in a rotated triangular configuration with a pitch-to-diameter ratio of 1.5 was tested. Four different angles of attack ranging for 0 degree (inline flexibility) through 30 and 60 degrees to 90 degrees (transverse flexibility) were studied. For each angle of attack several homogeneous void fractions have been tested (70%, 80%, 90%, and 95%). Stability test results show that the angle of attack strongly affect the tube bundle dynamic behavior. The different mechanisms underlying the fluidelastic instability are highlighted and the results compared to existing data on fluidelastic instability.