Effects of Rib Arrangements on Pressure Drop and Heat Transfer in a Rib-Roughened Channel With a Sharp 180 deg Turn

1997 ◽  
Vol 119 (3) ◽  
pp. 610-616 ◽  
Author(s):  
S. Mochizuki ◽  
A. Murata ◽  
M. Fukunaga

The objective of this study was to investigate, through experiments, the combined effects of a sharp 180 deg turn and rib patterns on the pressure drop performance and distributions of the local heat transfer coefficient in an entire two-pass rib-roughened channel with a 180 deg turn. The rib pitch-to-equivalent diameter ratio P/de was 1.0, the rib-height-to-equivalent diameter ratio e/de was 0.09, and the rib angle relative to the main flow direction was varied from 30 ∼ 90 deg with an interval of 15 deg. Experiments were conducted for Reynolds numbers in the range 4000 ∼ 30,000. It was disclosed that, due to the interactions between the bend-induced secondary flow and the rib-induced secondary flow, the combination of rib patterns in the channel before and after the turn causes considerable differences in the pressure drop and heat transfer performance of the entire channel.

1991 ◽  
Vol 113 (3) ◽  
pp. 590-596 ◽  
Author(s):  
J. C. Han ◽  
Y. M. Zhang ◽  
C. P. Lee

The effect of the rib angle orientation on the local heat transfer distributions and pressure drop in a square channel with two opposite in-line ribbed walls was investigated for Reynolds numbers from 15,000 to 90,000. The square channel composed of ten isolated copper sections has a length-to-hydraulic diameter ratio of 20; the rib height-to-hydraulic diameter ratio is 0.0625; the rib pitch-to-height ratio equals 10. Nine rib configurations were studied: 90 deg rib, 60 and 45 deg parallel ribs, 60 and 45 deg crossed ribs, 60 and 45 deg ∨-shaped ribs, and 60 and 45 deg ∧-shaped ribs. The results show that the 60 deg (or 45 deg) ∨-shaped rib performs better than the 60 deg (or 45 deg) parallel rib and, subsequently, better than the 60 deg (or 45 deg) crossed rib and the 90 deg rib. The ∨-shaped rib produces the highest heat transfer augmentation, while the ∧-shaped rib generates the greatest pressure drop. The crossed rib has the lowest heat transfer enhancement and the smallest pressure drop penalty.


2000 ◽  
Author(s):  
Lie-Jin Guo ◽  
Zi-Ping Feng

Abstract In the present paper the experiments for subcooled water flow and steam-water two-phase flow were conducted to investigate the effects of pulsation upon transient heat transfer characteristics in a closed-circulation helical-coiled tube steam generator. The non-uniform property of local heat transfer with steady flow was also examined. The secondary flow mechanism and the effect of interaction between the flow oscillation and secondary flow were analyzed on the basis of the experimental data. Some new phenomena were observed and explained. A series of correlations were proposed for the average and local heat transfer coefficients both under steady and oscillatory flow conditions. The results showed that there were considerable variations in local and peripherally time-averaged Nusselt numbers for pulsating flow in a wide range of parameters. Systematic investigations of pressure drop type oscillations and their thresholds for steam-water two-phase flow in a uniformly heated helical tube were also reported.


1987 ◽  
Vol 109 (1) ◽  
pp. 43-48 ◽  
Author(s):  
J. W. Baughn ◽  
H. Iacovides ◽  
D. C. Jackson ◽  
B. E. Launder

The paper reports extensive connective heat transfer data for turbulent flow of air around a U-bend with a ratio of bend radius:pipe diameter of 3.375:1. Experiments cover Reynolds numbers from 2 × 104 to 1.1 × 105. Measurements of local heat transfer coefficient are made at six stations and at five circumferential positions at each station. At Re = 6 × 104 a detailed mapping of the temperature field within the air is made at the same stations. The experiment duplicates the flow configuration for which Azzola and Humphrey [3] have recently reported laser-Doppler measurements of the mean and turbulent velocity field. The measurements show a strong augmentation of heat transfer coefficient on the outside of the bend and relatively low levels on the inside associated with the combined effects of secondary flow and the amplification/suppression of turbulent mixing by streamline curvature. The peak level of Nu occurs halfway around the bend at which position the heat transfer coefficient on the outside is about three times that on the inside. Another feature of interest is that a strongly nonuniform Nu persists six diameters downstream of the bend even though secondary flow and streamline curvature are negligible there. At the entry to the bend there are signs of partial laminarization on the inside of the bend, an effect that is more pronounced at lower Reynolds numbers.


1993 ◽  
Vol 115 (3) ◽  
pp. 560-567 ◽  
Author(s):  
N. Zhang ◽  
J. Chiou ◽  
S. Fann ◽  
W.-J. Yang

Experiments are performed to determine the local heat transfer performance in a rotating serpentine passage with rib-roughened surfaces. The ribs are placed on the trailing and leading walls in a corresponding posited arrangement with an angle of attack of 90 deg. The rib height-to-hydraulic diameter ratio, e/Dh, is 0.0787 and the rib pitch-to-height ratio, s/e, is 11. The throughflow Reynolds number is varied, typically at 23,000, 47,000, and 70,000 in the passage both at rest and in rotation. In the rotation cases, the rotation number is varied from 0.023 to 0.0594. Results for the rib-roughened serpentine passages are compared with those of smooth ones in the literature. Comparison is also made on results for the rib-roughened passages between the stationary and rotating cases. It is disclosed that a significant enhancement is achieved in the heat transfer in both the stationary and rotating cases resulting from an installation of the ribs. Both the rotation and Rayleigh numbers play important roles in the heat transfer performance on both the trailing and leading walls. Although the Reynolds number strongly influences the Nusselt numbers in the rib-roughened passage of both the stationary and rotating cases, Nuo and Nu, respectively, it has little effect on their ratio Nu/Nuo.


1983 ◽  
Vol 105 (4) ◽  
pp. 851-861 ◽  
Author(s):  
E. M. Sparrow ◽  
W. Q. Tao

Experiments were performed in a flat rectangular duct to determine the heat transfer and pressure drop response to periodic, rod-type disturbance elements situated adjacent to one principal wall and oriented transverse to the flow direction. In a portion of the experiments, heat transfer occurred only at the rodded wall, while in the remainder, heat was transferred at both principal walls of the duct. Highly detailed axial distributions of the local heat transfer coefficient were obtained. These distributions revealed the rapid establishment of a periodic (i.e., cyclic) fully developed regime as well as recurring local maxima and minima. Cycle-average, fully developed heat transfer coefficients were evaluated and were found to be much larger than those for a smooth-walled duct. Linear pressure distributions were measured between periodically positioned stations in the fully developed region, and the corresponding friction factors were several times greater than the smooth-duct values. The heat transfer and friction data were very well correlated using parameters that take account of the effective surface roughness associated with the disturbance rods.


2006 ◽  
Vol 129 (2) ◽  
pp. 188-199 ◽  
Author(s):  
Shyy Woei Chang ◽  
Tong-Minn Liou ◽  
Jui-Hung Hung ◽  
Wen-Hsien Yeh

This paper describes an experimental study of heat transfer in a radially rotating square duct with two opposite walls roughened by 45deg staggered ribs. Air coolant flows radially outward in the test channel with experiments to be undertaken that match the actual engine conditions. Laboratory-scale heat transfer measurements along centerlines of two rib-roughened surfaces are performed with Reynolds number (Re), rotation number (Ro), and density ratio (Δρ∕ρ) in the ranges of 7500–15,000, 0–1.8, and 0.076–0.294. The experimental rig permits the heat transfer study with the rotation number considerably higher than those studied in other researches to date. The rotational influences on cooling performance of the rib-roughened channel due to Coriolis forces and rotating buoyancy are studied. A selection of experimental data illustrates the individual and interactive impacts of Re, Ro, and buoyancy number on local heat transfer. A number of experimental-based observations reveal that the Coriolis force and rotating buoyancy interact to modify heat transfer even if the rib induced secondary flows persist in the rotating channel. Local heat transfer ratios between rotating and static channels along the centerlines of stable and unstable rib-roughened surfaces with Ro varying from 0.1 to 1.8 are in the ranges of 0.6–1.6 and 1–2.2, respectively. Empirical correlations for periodic flow regions are developed to permit the evaluation of interactive and individual effects of ribflows, convective inertial force, Coriolis force, and rotating buoyancy on heat transfer.


Author(s):  
Jared M. Pent ◽  
Jay S. Kapat ◽  
Mark Ricklick

This paper examines the local and averaged endwall heat transfer effects of a staggered array of porous aluminum pin fins with a channel blockage ratio (blocked channel area divided by open channel area) of 50%. Two sets of pins were used with pore densities of 0 (solid) and 10 pores per inch (PPI). The pressure drop through the channel was also determined for several flow rates using each set of pins. Local heat transfer coefficients on the endwall were measured using Thermochromatic Liquid Crystal (TLC) sheets recorded with a charge-coupled device (CCD) camera. Static and total pressure measurements were taken at the entrance and exit of the test section to determine the overall pressure drop through the channel and explain the heat transfer trends through the channel. The heat transfer and pressure data was then compared to flow visualization tests that were run using a fog generator. Results are presented for the two sets of pins with Reynolds numbers between 25000 and 130000. Local HTC (heat transfer coefficient) profiles as well as spanwise and streamwise averaged HTC plots are displayed for both pin arrays. The thermal performance was calculated for each pin set and Reynolds number. All experiments were carried out in a channel with an X/D of 1.72, a Y/D of 2.0, and a Z/D of 1.72.


Author(s):  
Moyse´s Alberto Navarro ◽  
Andre´ Augusto Campagnole dos Santos

The spacer grids exert great influence on the thermal hydraulic performance of the PWR fuel assembly. The presence of the spacers has two antagonistic effects on the core: an increase of pressure drop due to constriction on the coolant flow area and increase of the local heat transfer downstream the grids caused by enhanced coolant mixing. The mixing vanes, present in most of the spacer grid designs, cause a cross and swirl flow between and in the subchannels, enhancing even more the local heat transfer at the cost of more pressure loss. Due to this important hydrodynamic feature the spacer grids are often improved aiming to obtain an optimal commitment between pressure drop and enhanced heat transfer. In the present work, the fluid dynamic performance downstream a 5 × 5 rod bundle with spacer grids is analyzed with a commercial CFD code (CFX 11.0). Eleven different split vane spacer grids with angles from 16° to 36° and a spacer without vanes were evaluated. The computational domain extends from ∼10 Dh upstream to ∼50 Dh downstream the spacer grids. The standard k-ε turbulence model with scalable wall functions and the total energy model were used in the simulations. The results show a considerable increase of the average Nusselt number and secondary mixing with the angle of the vane up to ∼20 Dh downstream the spacer, reducing greatly the influence of the vane angle beyond this region. As expected, the pressure loss through the spacer grid also showed considerable increase with the vane angle.