Thermocapillary Effects on the Stability of a Heated, Curved Meniscus

1998 ◽  
Vol 120 (1) ◽  
pp. 220-226 ◽  
Author(s):  
D. M. Pratt ◽  
J. R. Brown ◽  
K. P. Hallinan

An investigation of thermocapillary effects on heated menisci formed by volatile liquids in capillary pumped heat transfer devices has been conducted. This research was motivated by the importance of the evaporation process from porous or grooved media integral to the operation of capillary pumped heat transport devices such as heat pipes and capillary pumped loops. From analysis, a criteria was established which predicts the thermal conditions at which the destablizing influences of thermocapillary stresses near the contact line of a heated and evaporating meniscus cause the meniscus to become unstable. Experimentally, two different idealized models of capillary pumped phase change loops were investigated to assess the suitability of the predictions. Correspondence between theory and experiment was observed. Given the observed dry-out of the evaporator at higher heat inputs after the meniscus becomes unstable, the importance of predicting the conditions at the instability onset is made clear.

Author(s):  
N. Manikanda Prabu ◽  
S. Nallusamy ◽  
G. Sureshkannan

Removal of heat generation is an important characteristic needs to be considered in electromechanical and electronic devices which improve the stability and feasibility of system. Despite numerous cooling methods, heat pipes are recent updating in research line. Heat pipes are one of the super conducting medium of heat energy and it is being used as an equipment to absorb more heat through phase change process of cooling medium circulated in it. It ensures the direct enhancement in heat transfer capacity and characteristics. Nowadays, improvement of the thermal performance in heat pipes getting up with various technologies, especially combination of heat pipe and Nano fluids. It has been experimentally practiced and various results are observed by previous researches that wick structure also a part of reason in improvement. The aim of this research work is to analyze the influence of wick material to improve heat transfer characteristics in heat pipes. In addition, combination of nano coated wick material with heat pipes is comparatively analyzed. From the final observed results it was found that, the best combination of wick material is supporting the better cooling requirements in electronic devices.


Mathematics ◽  
2020 ◽  
Vol 8 (9) ◽  
pp. 1448
Author(s):  
Anand Kumar ◽  
Vinod K. Gupta ◽  
Neetu Meena ◽  
Ishak Hashim

In this article, a study on the stability of Walter-B viscoelastic fluid in the highly permeable porous medium under the rotational speed modulation is presented. The impact of rotational modulation on heat transport is performed through a weakly nonlinear analysis. A perturbation procedure based on the small amplitude of the perturbing parameter is used to study the combined effect of rotation and permeability on the stability through a porous medium. Rayleigh–Bénard convection with the Coriolis expression has been examined to explain the impact of rotation on the convective flow. The graphical result of different parameters like modified Prandtl number, Darcy number, Rayleigh number, and Taylor number on heat transfer have discussed. Furthermore, it is found that the modified Prandtl number decelerates the heat transport which may be due to the combined effect of elastic parameter and Taylor number.


Volume 3 ◽  
2004 ◽  
Author(s):  
R. Kempers ◽  
A. Robinson ◽  
C. Ching ◽  
D. Ewing

A study was performed to experimentally characterize the effect of fluid loading on the heat transport performance of wicked heat pipes. In particular, experiments were performed to characterize the performance of heat pipes with insufficient fluid to saturate the wick and excess fluid for a variety of orientations. It was found that excess working fluid in the heat pipe increased the thermal resistance of the heat pipe, but increased maximum heat flux through the pipe in a horizontal orientation. The thermal performance of the heat pipe was reduced when the amount of working fluid was less than required to saturate the wick, but the maximum heat flux through the heat pipe was significantly reduced at all orientations. It was also found in this case the performance of this heat pipe deteriorated once dry-out occurred.


2005 ◽  
Author(s):  
Yao-Chen Chan ◽  
Wei-Keng Lin

In traditional heat pipe performance test, to keep an adiabatic temperature at a constant value, the evaporator wall temperature would be slowly increased when the thermal power was step input to the evaporator of the heat pipe. The maximum heat transfer rate (Qmax) was then defined that when the evaporator wall temperature rapidly increased at a certain amount of power input to the heat pipe. However, it is not easy to distinguish this sharp increased curve and sometimes result in the wrong Qmax data. In addition, it took too long for waiting the evaporator temperature approach to a steady state, thus this process could not use be for the fully check Qmax of the heat pipe. In this paper, we propose a novel quick test method to predict the maximum heat dissipation of the heat pipes namely Dynamic-Temperature-Tracing (D.T.T). The concept of the D.T.T was when we tracing the evaporator and the adiabatic wall temperature, these two temperature curves should be the same trend before the dry-out phenomena was occurred. Theoretically, when the dry-out start to occur in the heat pipe, the adiabatic temperature profile was no longer kept the same temperature profile as that of the evaporator. Hence, the maximum heat dissipate ability of the heat pipe was then easy to obtained at this measuring adiabatic temperature. The data were also compared with those obtained from the traditional standard method at the same equivalent evaporator length, condenser length and adiabatic temperature. In this experiments, sinter powder and groove heat pipes with diameter 6mm 8mm and 200mm length were selected as the capillary wick structure. Comparing with traditional method results, the errors of maximum heat transfer rate are less than 15%. The results also shown D.T.T. method is much fast and reliable compare with the traditional test method.   This paper was also originally published as part of the Proceedings of the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems.


Author(s):  
Mustafa Özçatalbaş ◽  
Ramazan Aykut Sezmen

Abstract Heat pipes are passive two-phase heat transfer devices that used in various heat transport applications because of their high thermal conductance capacities with low temperature differences. One of these applications is aerospace avionics that heat pipes are exposed to transient heat loads. Although heat pipes have been one of the heat removal alternatives for compact electronic devices, they have some restrictions during the usage in such high heat flux areas. In order to use heat pipes as effective heat removal devices, operating heat load range should not be exceeded during the operation of avionics or electronic devices. Out of these operating range, heat pipes no longer perform as effective heat removal devices because of phenomena called dry-out. In this study, a novel Finite Element (FE) Analysis Method was developed to model transient heat transfer behavior in heat pipes including dry-out phenomenon. Transient heat transfer analysis using Finite Element Method (FEM) was conducted to investigate heat pipe thermal performance considering heat flux dependent thermal conductivity under randomly varying heat inputs, which were assumed as heat dissipation of an electronic device. Validation of the FE model was done by using the results given in the literature. Heat pipe was made of Al with a length of LHP = 200 mm. Heat flux and convective heat transfer boundary conditions were used at the evaporator and condenser sections, respectively. Effective thermal conductivity of heat pipe, keff, was calculated by using the heat input depended thermal resistance, Rth, values given in literature. Under transient heat loads, heat flux dependent effective thermal conductivity was defined using user defined subroutines to simulate the dry-out. The transient heat transfer analysis was conducted using ABAQUS commercially available software. Temperature differences between evaporator and condenser sections, ΔT = Te−Tc, and thermal resistance, Rth, values are calculated for varying heat input values and compared with the results that provided in literature.