Experimental Investigation on Pulsating Horizontal Heating of a Water-Filled Enclosure

1996 ◽  
Vol 118 (4) ◽  
pp. 889-896 ◽  
Author(s):  
B. V. Antohe ◽  
J. L. Lage

Experimental results of the natural convection generated by the time periodic horizontal heating of a square cross-section enclosure filled with water are reported. A pulsating (on/off) heat flux is delivered to the heating wall of the enclosure, with the opposite wall cooled by a high thermal capacitance system. All other surfaces are insulated. Heating periods from 32 to 1600 seconds and cycle-averaged heat-flux based Rayleigh numbers from 2.5 × 108 to 1.0 × 109 are considered. Results presented in terms of time series, phase-plane portraits, and cyclic evolution of surface-averaged cooling and heating wall temperatures illustrate the main characteristics of the evolution to periodic regime. Also presented are the cycle-averaged heat transfer coefficient versus heating period, and the corresponding average Nusselt number versus Rayleigh number for various heating frequencies. These results, which support published theoretical and numerical analysis, indicate that by tuning the heating period properly, the heat transfer across an enclosure can be enhanced. The results also reveal that short heating periods hinder the convection within the enclosure, in general (e.g., for Ra = 7.5 × 108 and a period of 32 s the heat transfer coefficient is 13 percent smaller than the steady heating value). The sensitivity of the transport phenomenon to pulsating heat is shown to depend strongly on Ra. Finally, a correlation for estimating the maximum heat transfer coefficient, derived from the experimental results, is presented.

2008 ◽  
Author(s):  
Mukta S. Limaye ◽  
James F. Klausner

A flat and flexible evaporator, which conforms to contoured surfaces, has been developed for loop heat pipe applications. A loop heat pipe (LHP) is a passive, two phase heat transfer device that uses a porous membrane in the evaporator to circulate fluid. A number of flexible membranes have been tested as evaporator wicks that have a length of 12.7 cm and heated area of 50.6 cm2. For cellulose, polyethylene, and blotting paper membranes, maximum heat fluxes of 0.43, 1.5 and 2.9 W/cm2 have been observed, respectively. The maximum heat transfer coefficients measured for these membranes are 551, 876, and 2100 W/m2-K, respectively. The best performance was observed by a membrane made of a fibrous cotton matrix, typically used as gauze. This material has a large pore size and high wettability with water. When tested in a rigid, brass evaporator, the maximum heat flux observed is 5.95 W/cm2, and the maximum heat transfer coefficient is 2865 W/m2-K. A flexible evaporator is fabricated using a heat sealable, flexible barrier pouch, and the cotton matrix membrane is sealed inside. The maximum measured heat flux for the flexible evaporator is 3.2 W/cm2 and maximum measured heat transfer coefficient is 1165 W/m2-K. The observed reduction in heat transfer as compared to the rigid evaporator is due to the poor contact between the evaporator and membrane. It is concluded that for the flexible evaporator membranes considered, the heat transfer mechanism is boiling and the maximum heat flux is limited by the wicking rate of the membrane. For a given membrane, the wicking rate increases with a reduction in the wicking length and decreases with an increasing rate of evaporation. To further improve the performance of the flexible evaporator, it is necessary to ensure efficient vapor removal from the evaporator as well as maintaining good contact between the membrane and the evaporator surface.


Author(s):  
Obaid ur Rehman ◽  
Marappa Gounder Ramasamy ◽  
Nor Erniza M Rozali ◽  
Umesh B. Deshannavar

Finding the limiting heat flux above which nucleate boiling starts and below which forced convective heat transfer exists is a crucial task for the accuracy of results from crude oil fouling tests. In this study, crude oils from two sources were tested at bulk temperatures of 100, 120 and 140 °C and different velocities. Heat transfer coefficient increased gradually with bulk temperature indicated lowering of the viscosity at high temperatures which promoted turbulence and enhanced heat transfer. The velocity effects were similar to that of bulk temperatures on maximum heat transfer coefficient while less heat flux was required to achieve the same surface temperature at lower velocities. Deshannavar and Ramasamy’s model to predict maximum heat flux was compared with experimental results and a poor estimation was observed for the crude oils tested.


2017 ◽  
Vol 29 (1) ◽  
pp. 44-48
Author(s):  
KM Tanvir Ahmmed ◽  
Sultana Razia Syeda

In this study saturated nucleate pool boiling of water with sodium oleate surfactant on a horizontal cylindrical heater surface has been investigated experimentally and compared with that of demineralized water. The concentration of sodium oleate in water was 100-300 ppm. The experimental results show that a small amount of surfactant enhances the heat transfer coefficient significantly. At low surfactant concentrations, heat transfer coefficient increases with increasing surfactant concentration in water. The maximum heat transfer enhancement is found to be at 250 ppm of sodium oleate solution. By adding more surfactant to water, heat transfer coefficient is found to be lowered. Surface tension of different concentration of sodium oleate solutions is measured. It is observed that the maximum heat transfer coefficient is obtained at a surfactant concentration that corresponds to the critical micelle concentration (cmc) of the sodium oleate solution.Journal of Chemical Engineering, Vol. 29, No. 1, 2017: 44-48


2019 ◽  
Vol 9 ◽  
pp. 184798041987646 ◽  
Author(s):  
XiaoRong Zhou ◽  
Yi Wang ◽  
Kai Zheng ◽  
Haozhong Huang

In this study, the cooling performance of nanofluids in car radiators was investigated. A car radiator, temperature measuring instrument, and other components were used to set up the experimental device, and the temperature of nanofluids passing through the radiator was measured by this device. Three kinds of nanoparticles, γ-Al2O3, α-Al2O3, and ZnO, were added to propylene glycol to prepared nanofluids, and the effects of nanoparticle size and type, volume concentration, initial temperature, and flow rate were tested. The results indicated that the heat transfer coefficients of all nanofluids first increased and then decreased with an increase in volume concentration. The ZnO-propylene glycol nanofluid reached a maximum heat transfer coefficient at 0.3 vol%, and the coefficient decreased by 25.6% with an increase in volume concentration from 0.3 vol% to 0.5 vol%. Smaller particles provided a better cooling performance, and the 0.1 vol% γ-Al2O3-propylene glycol nanofluid had a 19.9% increase in heat transfer coefficient compared with that of α-Al2O3-propylene glycol. An increase in flow rate resulted in a 10.5% increase in the heat transfer coefficient of the 0.5 vol% α-Al2O3-propylene glycol nanofluid. In addition, the experimental temperature range of 40–60°C improved the heat transfer coefficient of the 0.2 vol% ZnO-propylene glycol nanofluid by 46.4%.


Author(s):  
M. Hamayun Maqbool ◽  
Bjo¨rn Palm ◽  
R. Khodabandeh ◽  
Rashid Ali

Experiments have been performed to investigate heat transfer in a circular vertical mini channel made of stainless steel (AISI 316) with internal diameter of 1.70 mm and a uniformly heated length of 245 mm using ammonia as working fluid. The experiments are conducted for a heat flux range of 15 to 350 kW/m2 and mass flux range of 100 to 500 kg/m2s. The effects of heat flux, mass flux and vapour quality on the heat transfer coefficient are explored in detail. The experimental results show that the heat transfer coefficient increases with imposed wall heat flux while mass flux and vapour quality have no considerable effect. Experimental results are compared to predictive methods available in the literature for boiling heat transfer. The correlations of Cooper et al. [1] and Shah [3] are in good agreement with our experimental data.


2015 ◽  
Vol 138 (3) ◽  
Author(s):  
Steve Q. Cai ◽  
Avijit Bhunia

In a heat pipe, operating fluid saturates wick structures system and establishes a capillary-driven circulation loop for heat transfer. Thus, the thermophysical properties of the operating fluid inevitably impact the transitions of phase-change mode and the capability of heat transfer, which determine both the design and development of the associated heat pipe systems. This article investigates the effect of liquid properties on phase-change heat transfer. Two different copper wick structures, cubic and cylindrical in cross section, 340 μm in height and 150 μm in diameter or width, are fabricated using an electroplating technique. The phase-change phenomena inside these wick structures are observed at various heat fluxes. The corresponding heat transfer characteristics are measured for three different working liquids: water, ethanol, and Novec 7200. Three distinct modes of the phase-change process are identified: (1) evaporation on liquid–vapor interface, (2) nucleate boiling with interfacial evaporation, and (3) boiling enhanced interface evaporation. Transitions between the three modes depend on heat flux and liquid properties. In addition to the mode transition, liquid properties also dictate the maximum heat flux and the heat transfer coefficient. A quantitative characterization shows that the maximum heat flux scales with Merit number, a dimensionless number connecting liquid density, surface tension, latent heat of vaporization, and viscosity. The heat transfer coefficient, on the other hand, is dictated by the thermal conductivity of the liquid. A complex interaction between the mode transition and liquid properties is reflected in Novec 7200. In spite of having the lowest thermal conductivity among the three liquids, an early transition to the mode of the boiling enhanced interface evaporation leads to a higher heat transfer coefficient at low heat flux.


2021 ◽  
pp. 199-199
Author(s):  
Lakshmi Reddy ◽  
Srinivasa Bayyapureddy Reddy ◽  
Kakumani Govindarajulu

Heat pipe is a two phase heat transfer device with high effective thermal conductivity and transfer huge amount of heat with minimum temperature gradient in between evaporator and condenser section. This paper objective is to predict the thermal performance in terms of thermal resistance (R) and heat transfer coefficient (h) of screen mesh wick heat pipe with DI water-TiO2 as working fluid. The input process parameters of heat pipe such as heat load (Q), tilt angle (?) and concentration of nanofluid (?) were modeled and optimized by utilizing Response Surface Methodology (RSM) with MiniTab-17 software to attain minimum thermal resistance and maximum heat transfer coefficient. The minimum thermal resistance of 0.1764 0C/W and maximum heat transfer coefficient of 1411.52 W/m2 0C was obtained under the optimized conditions of 200 W heat load, 57.20 tilt angle and 0.159 vol. % concentration of nano-fluid.


Kerntechnik ◽  
2021 ◽  
Vol 86 (5) ◽  
pp. 325-337
Author(s):  
M. Kumar ◽  
D. Mukhopadhyay

Abstract Empirical correlations are developed for rewetting velocity and maximum heat transfer coefficient during rewetting phase of single hot vertical Fuel Pin Simulator (FPS) by using radial jet impingement and falling film. Emergency Core Cooling System (ECCS) has been designed for Advance Heavy water Reactor (AHWR) to rewet the hot fuel pin under the loss of coolant accident. Coolant injection takes place from a water rod which is located at the center of the fuel bundle in form of jets to rewet hot surface of fuel pin under loss of coolant accident. This kind of design to reflood the fuel bundle is different than bottom and top spray reflooding practiced in PWR and BWR type of nuclear reactors. There are two different kinds of rewetting found during radial jet induced cooling. The first one is due to radial jet impingement and the second one is due to falling film which is below the jet impingement point. Rewetting velocity has been predicted along the length of fuel pin due to radial jet impingement cooling. Temperature of FPS has been varied from 400°C to 700°C with help of different powers supply, simulating decay heat of reactor. A variation of coolant radial jet mass flow rate is from 0.5 lpm to 1.8 lpm. It is considered during ECCS injection. It has been observed from the experiments that rewetting velocity decreases with increasing the clad surface temperature and increases with increasing the coolant mass flow rate. The rewetting velocity in falling film is found to be nearly 1.8 times higher than rewetting velocity predicted in circumferential direction. Further, it is found that maximum heat transfer coefficient increases with increasing the radial jet coolant mass flow rate. The maximum heat transfer coefficient in case of radial jet impingement is found to be nearly 1.5 times the falling film rewetting. Developed correlation predicts the maximum heat transfer coefficient with experimental data well within the error band of ±10%.


Sign in / Sign up

Export Citation Format

Share Document