scholarly journals A Fluid-Structure Interaction Finite Element Analysis of Pulsatile Blood Flow Through a Compliant Stenotic Artery

1999 ◽  
Vol 121 (4) ◽  
pp. 361-369 ◽  
Author(s):  
M. Bathe ◽  
R. D. Kamm

A new model is used to analyze the fully coupled problem of pulsatile blood flow through a compliant, axisymmetric stenotic artery using the finite element method. The model uses large displacement and large strain theory for the solid, and the full Navier-Stokes equations for the fluid. The effect of increasing area reduction on fluid dynamic and structural stresses is presented. Results show that pressure drop, peak wall shear stress, and maximum principal stress in the lesion all increase dramatically as the area reduction in the stenosis is increased from 51 to 89 percent. Further reductions in stenosis cross-sectional area, however, produce relatively little additional change in these parameters due to a concomitant reduction in flow rate caused by the losses in the constriction. Inner wall hoop stretch amplitude just distal to the stenosis also increases with increasing stenosis severity, as downstream pressures are reduced to a physiological minimum. The contraction of the artery distal to the stenosis generates a significant compressive stress on the downstream shoulder of the lesion. Dynamic narrowing of the stenosis is also seen, further augmenting area constriction at times of peak flow. Pressure drop results are found to compare well to an experimentally based theoretical curve, despite the assumption of laminar flow.

2019 ◽  
Vol 12 (4) ◽  
pp. 1083-1091 ◽  
Author(s):  
O. ElBanhawy ◽  
A. Guaily ◽  
M. Tosson ◽  
◽  
◽  
...  

2021 ◽  
Vol 68 (1) ◽  
Author(s):  
Md. Alamgir Kabir ◽  
Md. Ferdous Alam ◽  
Md. Ashraf Uddin

AbstractNumerical simulations of pulsatile transitional blood flow through symmetric stenosed arteries with different area reductions were performed to investigate the behavior of the blood. Simulations were carried out through Reynolds averaged Navier-Stokes equations and well-known k-ω model was used to evaluate the numerical simulations to assess the changes in velocity distribution, pressure drop, and wall shear stress in the stenosed artery, artery with single and double stenosis at different area reduction. This study found a significant difference in stated fluid properties among the three types of arteries. The fluid properties showed a peak in an occurrence at the stenosis for both in the artery with single and double stenosis. The magnitudes of stated fluid properties increase with the increase of the area reduction. Findings may enable risk assessment of patients with cardiovascular diseases and can play a significant role to find a solution to such types of diseases.


1997 ◽  
Vol 35 (4) ◽  
pp. 375-385 ◽  
Author(s):  
W.J. Vankan ◽  
J.M. Huyghe ◽  
J.D. Janssen ◽  
A. Huson ◽  
W.J.G. Hacking ◽  
...  

2020 ◽  
Vol 25 (2) ◽  
pp. 33-38
Author(s):  
Puskar R. Pokhrel ◽  
Jeevan Kafle ◽  
Parameshwari Kattel ◽  
Hari Prasad Gaire

Arterial stenosis is an abnormal condition in arteries due to the deposition of fats and other substances, called atherosclerosis.  As it restricts the blood flow, it may induce a heart attack. Employing the Navier-Stokes equations, we consider the blood flow in an artery with the presence of a stenosis in an axisymmetric shape. We analyze the blood flow dynamics in cylindrical form by evaluating pressure, pressure drop against the wall, shear stress on the wall. We also analyze the dynamics by evaluating the ratio of pressure drop with stenosis to the pressure drop without stenosis against the wall, and the ratio of maximum to minimum shear stresses with the ratios of various thicknesses of stenosis to radius of the artery.


Dynamics ◽  
2021 ◽  
Vol 1 (1) ◽  
pp. 9-17
Author(s):  
Andrea Natale Impiombato ◽  
Giorgio La Civita ◽  
Francesco Orlandi ◽  
Flavia Schwarz Franceschini Zinani ◽  
Luiz Alberto Oliveira Rocha ◽  
...  

As it is known, the Womersley function models velocity as a function of radius and time. It has been widely used to simulate the pulsatile blood flow through circular ducts. In this context, the present study is focused on the introduction of a simple function as an approximation of the Womersley function in order to evaluate its accuracy. This approximation consists of a simple quadratic function, suitable to be implemented in most commercial and non-commercial computational fluid dynamics codes, without the aid of external mathematical libraries. The Womersley function and the new function have been implemented here as boundary conditions in OpenFOAM ESI software (v.1906). The discrepancy between the obtained results proved to be within 0.7%, which fully validates the calculation approach implemented here. This approach is valid when a simplified analysis of the system is pointed out, in which flow reversals are not contemplated.


2015 ◽  
Vol 105 ◽  
pp. 877-884 ◽  
Author(s):  
Khairuzzaman Mamun ◽  
Most. Nasrin Akhter ◽  
Md. Shirazul Hoque Mollah ◽  
Md. Abu Naim Sheikh ◽  
Mohammad Ali

2018 ◽  
Vol 8 (8) ◽  
pp. 1309 ◽  
Author(s):  
Andrzej Polanczyk ◽  
Aleksandra Piechota-Polanczyk ◽  
Christoph Domenig ◽  
Josif Nanobachvili ◽  
Ihor Huk ◽  
...  

Background: We aimed to verify the accuracy of the Computational Fluid Dynamics (CFD) algorithm for blood flow reconstruction for type IIIb aortic dissection (TBAD) before and after thoracic endovascular aortic repair (TEVAR). Methods: We made 3D models of the aorta and its branches using pre- and post-operative CT data from five patients treated for TBAD. The CFD technique was used to quantify the displacement forces acting on the aortic wall in the areas of endograft, mass flow rate/velocity and wall shear stress (WSS). Calculated results were verified with ultrasonography (USG-Doppler) data. Results: CFD results indicated that the TEVAR procedure caused a 7-fold improvement in overall blood flow through the aorta (p = 0.0001), which is in line with USG-Doppler data. A comparison of CFD results and USG-Doppler data indicated no significant change in blood flow through the analysed arteries. CFD also showed a significant increase in flow rate for thoracic trunk and renal arteries, which was in accordance with USG-Doppler data (accuracy 90% and 99.9%). Moreover, we observed a significant decrease in WSS values within the whole aorta after TEVAR compared to pre-TEVAR (1.34 ± 0.20 Pa vs. 3.80 ± 0.59 Pa, respectively, p = 0.0001). This decrease was shown by a significant reduction in WSS and WSS contours in the thoracic aorta (from 3.10 ± 0.27 Pa to 1.34 ± 0.11Pa, p = 0.043) and renal arteries (from 4.40 ± 0.25 Pa to 1.50 ± 0.22 Pa p = 0.043). Conclusions: Post-operative remodelling of the aorta after TEVAR for TBAD improved hemodynamic patterns reflected by flow, velocity and WSS with an accuracy of 99%.