Second Law Analysis of Adsorption Cycles With Thermal Regeneration

1996 ◽  
Vol 118 (3) ◽  
pp. 229-236 ◽  
Author(s):  
M. Pons

Adsorption processes can be used for operating environment-friendly refrigeration cycles. When combined with the thermal regeneration process, these cycles can have quite high performance. The second law analysis of the adsorption cycles with thermal regeneration is fully developed. The different heat transports between heat transfer fluid and adsorbent, between adsorbate and condenser/evaporator heat sources, and between heat transfer fluid and heat sources are analyzed. The entropy balance is then completely established. Consistency between the first law and second law analysis is verified by the numerical values of the entropy productions. The optimal Operation of an adsorber is then described, and the study of those optimal conditions lead to some correlation between the different internal entropy productions.

2021 ◽  
Vol 5 (10) ◽  
pp. 277
Author(s):  
Soudeh Iranmanesh ◽  
Mahyar Silakhori ◽  
Mohammad S. Naghavi ◽  
Bee C. Ang ◽  
Hwai C. Ong ◽  
...  

Recently, nanofluid application as a heat transfer fluid for a closed-loop solar heat collector is receiving great attention among the scientific community due to better performance. The performance of solar systems can be assessed effectively with the exergy method. The present study deals with the thermodynamic performance of the second law analysis using graphene nanoplatelets nanofluids. Second law analysis is the main tool for explaining the exergy output of thermodynamic and energy systems. The performance of the closed-loop system in terms of energy and exergy was determined by analyzing the outcome of field tests in tropical weather conditions. Moreover, three parameters of entropy generation, pumping power and Bejan number were also determined. The flowrates of 0.5, 1 and 1.5 L/min and GNP mass percentage of 0.025, 0.5, 0.075 and 0.1 wt% were used for these tests. The results showed that in a flow rate of 1.5 L/min and a concentration of 0.1 wt%, exergy and thermal efficiencies were increased to about 85.5 and 90.7%, respectively. It also found that entropy generation reduced when increasing the nanofluid concentration. The Bejan number surges up when increasing the concentration, while this number decreases with the enhancement of the volumetric flow rate. The pumping power of the nanofluid-operated system for a 0.1 wt% particle concentration at 0.5 L/min indicated 5.8% more than when pure water was used as the heat transfer fluid. Finally, this investigation reveals the perfect conditions that operate closest to the reversible limit and helps the system make the best improvement.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3298
Author(s):  
Gianpiero Colangelo ◽  
Brenda Raho ◽  
Marco Milanese ◽  
Arturo de Risi

Nanofluids have great potential to improve the heat transfer properties of liquids, as demonstrated by recent studies. This paper presents a novel idea of utilizing nanofluid. It analyzes the performance of a HVAC (Heating Ventilation Air Conditioning) system using a high-performance heat transfer fluid (water-glycol nanofluid with nanoparticles of Al2O3), in the university campus of Lecce, Italy. The work describes the dynamic model of the building and its heating and cooling system, realized through the simulation software TRNSYS 17. The use of heat transfer fluid inseminated by nanoparticles in a real HVAC system is an innovative application that is difficult to find in the scientific literature so far. This work focuses on comparing the efficiency of the system working with a traditional water-glycol mixture with the same system that uses Al2O3-nanofluid. The results obtained by means of the dynamic simulations have confirmed what theoretically assumed, indicating the working conditions of the HVAC system that lead to lower operating costs and higher COP and EER, guaranteeing the optimal conditions of thermo-hygrometric comfort inside the building. Finally, the results showed that the use of a nanofluid based on water-glycol mixture and alumina increases the efficiency about 10% and at the same time reduces the electrical energy consumption of the HVAC system.


Coatings ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 498
Author(s):  
Wasim Ullah Khan ◽  
Muhammad Awais ◽  
Nabeela Parveen ◽  
Aamir Ali ◽  
Saeed Ehsan Awan ◽  
...  

The current study is an attempt to analytically characterize the second law analysis and mixed convective rheology of the (Al2O3–Ag/H2O) hybrid nanofluid flow influenced by magnetic induction effects towards a stretching sheet. Viscous dissipation and internal heat generation effects are encountered in the analysis as well. The mathematical model of partial differential equations is fabricated by employing boundary-layer approximation. The transformed system of nonlinear ordinary differential equations is solved using the homotopy analysis method. The entropy generation number is formulated in terms of fluid friction, heat transfer and Joule heating. The effects of dimensionless parameters on flow variables and entropy generation number are examined using graphs and tables. Further, the convergence of HAM solutions is examined in terms of defined physical quantities up to 20th iterations, and confirmed. It is observed that large λ1 upgrades velocity, entropy generation and heat transfer rate, and drops the temperature. High values of δ enlarge velocity and temperature while reducing heat transport and entropy generation number. Viscous dissipation strongly influences an increase in flow and heat transfer rate caused by a no-slip condition on the sheet.


Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1853 ◽  
Author(s):  
Pavel Neuberger ◽  
Radomír Adamovský

The efficiency of a heat pump energy system is significantly influenced by its low-temperature heat source. This paper presents the results of operational monitoring, analysis and comparison of heat transfer fluid temperatures, outputs and extracted energies at the most widely used low temperature heat sources within 218 days of a heating period. The monitoring involved horizontal ground heat exchangers (HGHEs) of linear and Slinky type, vertical ground heat exchangers (VGHEs) with single and double U-tube exchanger as well as the ambient air. The results of the verification indicated that it was not possible to specify clearly the most advantageous low-temperature heat source that meets the requirements of the efficiency of the heat pump operation. The highest average heat transfer fluid temperatures were achieved at linear HGHE (8.13 ± 4.50 °C) and double U-tube VGHE (8.13 ± 3.12 °C). The highest average specific heat output 59.97 ± 41.80 W/m2 and specific energy extracted from the ground mass 2723.40 ± 1785.58 kJ/m2·day were recorded at single U-tube VGHE. The lowest thermal resistance value of 0.07 K·m2/W, specifying the efficiency of the heat transfer process between the ground mass and the heat transfer fluid, was monitored at linear HGHE. The use of ambient air as a low-temperature heat pump source was considered to be the least advantageous in terms of its temperature parameters.


1990 ◽  
Vol 112 (2) ◽  
pp. 130-135 ◽  
Author(s):  
S. K. Som ◽  
A. K. Mitra ◽  
S. P. Sengupta

A second law analysis has been developed for an evaporative atomized spray in a uniform parallel stream of hot gas. Using a discrete droplet evaporation model, an equation for entropy balance of a drop has been formulated to determine numerically the entropy generation histories of the evaporative spray. For the exergy analysis of the process, the rate of heat transfer and that of associated irreversibilities for complete evaporation of the spray have been calculated. A second law efficiency (ηII), defined as the ratio of the total exergy transferred to the sum of the total exergy transferred and exergy destroyed, is finally evaluated for various values of pertinent input parameters, namely, the initial Reynolds number (Rei = 2ρgVixi/μg) and the ratio of ambient to initial drop temperature (Θ∞′/Θi′).


2021 ◽  
Vol 321 ◽  
pp. 02016
Author(s):  
Belkacem Bouali ◽  
Hanane-Maria Regue

This paper presents an analysis of the performance of a parabolic trough collector (PTC) according to some key operating parameters. The effects of the secondary reflector, the length and thickness of the absorber tube (receiver tube) and the flow rate of the heat transfer fluid (HTF) are investigated. The main objective is to determine an optimal operation, which improves the performance of a traditional PTC. The target variables are the temperature at the outlet of the tube, the amount of energy collected by the HTF and the efficiency of the system. The solar flux data concern the city of LAGHOUAT located in the south of Algeria. Four days in different seasons are considered. The optical analysis of the system is performed by using the open source SolTrace code. The output of this analysis is used as a boundary condition for the CFD solver. The conjugate heat transfer and the fluid flow through the absorber tube are simulated by using ANSYS-CFX solver. Water is considered as heat transfer fluids. The obtained results show that the use of a curved secondary reflector significantly improves the performance of the traditional PTC. As the thickness of the tube increases, the heat storage in the material increases, which increases the temperature at the exit of the tube and therefore the efficiency of the system. However, the length of the tube depends on the mass flow of the HTF and vice versa. To keep the efficiency constant by choosing another length, it is necessary to choose a mass flow rate proportional to the flow rate corresponding to the initial length.


2013 ◽  
Author(s):  
Adriano Sciacovelli ◽  
Elisa Guelpa ◽  
Vittorio Verda

Latent heat thermal energy storage (LHTES) systems based on phase change materials (PCMs) are a promising option to be employed as effective energy storage devices. PCM allows one to achieve high energy storage density and almost constant temperature energy retrieval, however LHTES systems performance is limited by poor thermal conductivity of the PCMs which leads to unacceptably low melting and solidification rates. Thus, heat transfer enhancement techniques are required in order to obtain acceptable melting and solidification rates. The preliminary design of a shell-and-tube LHTES unit is investigated by means of computational fluid-dynamics (CFD). Three different fin designs are considered: a conventional radial fin, a constructal Y-shaped fin design and a non-constructal Y-shaped configuration previously investigated by the authors. The performances of each fin configuration are evaluated by means of a Second-law analysis. Moreover, local and global entropy generation rates are analyzed in order to show the main source of thermodynamic irreversibilities occurring in the system. The analysis indicates that solidification rate is significantly enhanced when Y-shaped fins are adopted in the LHTES unit, however the constructal Y-shaped geometry is not optimal since further improvements can be achieved by means of a Y-shaped fins with elongated secondary branches.


1991 ◽  
Vol 113 (2) ◽  
pp. 89-93 ◽  
Author(s):  
Giampaolo Manfrida ◽  
Shukuru J. M. Kawambwa

A performance study is presented of a Rankine organic cycle powered by a low temperature solar collector. In this work a two-phase collector is considered where the heat transfer fluid is vaporized and its saturated vapor expands in a turbine according to a Rankine cycle. The collector system is divided into a boiling and a nonboiling (subcooled) part: The limit between the two depends upon the value of flow rate and radiation. A modified form of the Bliss equation is used to model the thermal performance of the collector in terms of thermal efficiency versus DTI [DTI= (Absorber average temperature-Ambient temperature)/ Solar Radiation]. The system is analyzed by second-law analysis, and it includes several exergy losses of different types (heat transfer, heat loss, etc.) which determine the overall exergy balance. Different working fluids are considered, and optimization to a certain extent is demonstrated from this point of view. In order to minimize irreversibilities and guarantee the most efficient conversion processes, the most important point is the right selection of the collector operating pressure level, which depends on the instantaneous value of radiation and ambient temperature (as well as on the collector thermal performance). The choice of the optimal pressure level is done by means of second-law arguments; the flow rates across the collector, the turbine, and the condenser are consequently determined. A simulation over a typical sunny day in Florence, Italy allows the calculation of the expected daily performance.


Sign in / Sign up

Export Citation Format

Share Document