Application of Deterministic Chaos Theory to Local Instantaneous Temperature, Pressure, and Heat Transfer Coefficients in a Gas Fluidized Bed

1996 ◽  
Vol 118 (3) ◽  
pp. 214-220 ◽  
Author(s):  
A. I. Karamavruc¸ ◽  
N. N. Clark

The local instantaneous temperature, heat transfer coefficient, and pressure data, gathered around a horizontal tube in a fluidized bed, have been analyzed using the deterministic chaos theory. A stainless steel heat transfer tube, carrying a hot water flow, was placed in a cold bubbling fluidized bed. The tube was instrumented in the circumferential direction with five fast-responding surface thermocouples and a vertical pressure differential sensor. The local temperature and pressure data were measured simultaneously at a frequency of 120 Hz. Additionally, the local instantaneous heat transfer coefficient was evaluated by solving the transient two-dimensional heat conduction equation across the tube wall numerically. The mutual information function (MIF) has been applied to the signals to observe the relationship between points separated in time. MIF was also used to provide the most appropriate time delay constant τ to reconstruct an m-dimensional phase portrait of the one-dimensional time series. The distinct variation of MIF around the tube indicates the variations of solid-surface contact in the circumferential direction. The correlation coefficient was evaluated to calculate the correlation exponentv, which is closely related to the fractal dimension. The correlation exponent is a measure of the strange attractor. The minimum embedding dimension as well as the degrees of freedom of the system were evaluated via the correlation coefficient. Kolmogorov entropies of the signals were approximated by using the correlation coefficient. Kolmogorov entropy considers the inherent multi-dimensional nature of chaotic data. A positive estimation of Kolmogorov entropy is an indication of the chaotic nature of the signal. The Kolmogorov entropies of the temperature data around the tube were found to be between 10 bits/s and 24 bits/s. A comparison between the signals has shown that the local instantaneous heat transfer coefficient exhibits a higher degree of chaos than the local temperature and pressure signals.

2019 ◽  
Vol 141 (2) ◽  
Author(s):  
Clifford K. Ho ◽  
Matthew Carlson ◽  
Kevin J. Albrecht ◽  
Zhiwen Ma ◽  
Sheldon Jeter ◽  
...  

This paper presents an evaluation of alternative particle heat-exchanger designs, including moving packed-bed and fluidized-bed designs, for high-temperature heating of a solar-driven supercritical CO2 (sCO2) Brayton power cycle. The design requirements for high pressure (≥20 MPa) and high temperature (≥700 °C) operation associated with sCO2 posed several challenges requiring high-strength materials for piping and/or diffusion bonding for plates. Designs from several vendors for a 100 kW-thermal particle-to-sCO2 heat exchanger were evaluated as part of this project. Cost, heat-transfer coefficient, structural reliability, manufacturability, parasitics and heat losses, scalability, compatibility, erosion and corrosion, transient operation, and inspection ease were considered in the evaluation. An analytic hierarchy process was used to weight and compare the criteria for the different design options. The fluidized-bed design fared the best on heat transfer coefficient, structural reliability, scalability, and inspection ease, while the moving packed-bed designs fared the best on cost, parasitics and heat losses, manufacturability, compatibility, erosion and corrosion, and transient operation. A 100 kWt shell-and-plate design was ultimately selected for construction and integration with Sandia's falling particle receiver system.


Author(s):  
E. A. Pitsuha ◽  
E. K. Buchilko ◽  
Yu. S. Teplitskii ◽  
D. S. Slizhuk

An experimental investigation of the heat-transfer coefficient to a spherical probe in a cyclone-bed chamber with fluidized bed in the “cold” and “hot” regimes has been carried out. The heat-transfer coefficient was determined by the regular thermal regime. The dependences of the heat-transfer coefficient in the vortex-bed furnace on the various parameters: the diameter of the outlet hole, the air flow rate, the share of the bottom blast and the location of the probe were determined. It is revealed that in the “cold” regime the heat-transfer coefficient has practically constant value in the radial direction, it almost does not depend on the diameter of the outlet hole and the share of the bottom blast and depends significantly on the position of the probe along the height of the furnace and the air flow rate. The effect of flow swirling on the heat-transfer coefficient in a cyclone-bed chamber with fluidized bed is determined. When the fuel burns (“hot” regime), the heat-transfer coefficient is not constant in the radial direction and accept the maximum values in the central area of the chamber. At the same time, the part of conductive-convective component in the total heat-transfer coefficient to the spherical probe, depending on its radial position, is estimated at 40–70 %. The results can be used in the design and creation of modern high-efficiency furnaces for burning local solid biofuels.


Sign in / Sign up

Export Citation Format

Share Document