Effect of a Cutback Squealer and Cavity Depth on Film-Cooling Effectiveness on a Gas Turbine Blade Tip

2008 ◽  
Vol 130 (2) ◽  
Author(s):  
Shantanu Mhetras ◽  
Diganta Narzary ◽  
Zhihong Gao ◽  
Je-Chin Han

Film-cooling effectiveness from shaped holes on the near tip pressure side and cylindrical holes on the squealer cavity floor is investigated. The pressure side squealer rim wall is cut near the trailing edge to allow the accumulated coolant in the cavity to escape and cool the tip trailing edge. Effects of varying blowing ratios and squealer cavity depth are also examined on film-cooling effectiveness. The film-cooling effectiveness distributions are measured on the blade tip, near tip pressure side and the inner pressure side and suction side rim walls using pressure sensitive paint technique. The internal coolant-supply passages of the squealer tipped blade are modeled similar to those in the GE-E3 rotor blade with two separate serpentine loops supplying coolant to the film-cooling holes. Two rows of cylindrical film-cooling holes are arranged offset to the suction side profile and along the camber line on the tip. Another row of shaped film-cooling holes is arranged along the pressure side just below the tip. The average blowing ratio of the cooling gas is controlled to be 0.5, 1.0, 1.5, and 2.0. A five-bladed linear cascade in a blow down facility with a tip gap clearance of 1.5% is used to perform the experiments. The free-stream Reynolds number, based on the axial chord length and the exit velocity, was 1,480,000 and the inlet and exit Mach numbers were 0.23 and 0.65, respectively. A blowing ratio of 1.0 is found to give best results on the pressure side, whereas the tip surfaces forming the squealer cavity give best results for M=2. Results show high film-cooling effectiveness magnitudes near the trailing edge of the blade tip due to coolant accumulation from upstream holes in the tip cavity. A squealer depth with a recess of 2.1mm causes the average effectiveness magnitudes to decrease slightly as compared to a squealer depth of 4.2mm.

2021 ◽  
Author(s):  
Izhar Ullah ◽  
Sulaiman M. Alsaleem ◽  
Lesley M. Wright ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This work is an experimental study of film cooling effectiveness on a blade tip in a stationary, linear cascade. The cascade is mounted in a blowdown facility with controlled inlet and exit Mach numbers of 0.29 and 0.75, respectively. The free stream turbulence intensity is measured to be 13.5 % upstream of the blade’s leading edge. A flat tip design is studied, having a tip gap of 1.6%. The blade tip is designed to have 15 shaped film cooling holes along the near-tip pressure side (PS) surface. Fifteen vertical film cooling holes are placed on the tip near the pressure side. The cooling holes are divided into a 2-zone plenum to locally maintain the desired blowing ratios based on the external pressure field. Two coolant injection scenarios are considered by injecting coolant through the tip holes only and both tip and PS surface holes together. The blowing ratio (M) and density ratio (DR) effects are studied by testing at blowing ratios of 0.5, 1.0, and 1.5 and three density ratios of 1.0, 1.5, and 2.0. Three different foreign gases are used to create density ratio effect. Over-tip flow leakage is also studied by measuring the static pressure distributions on the blade tip using the pressure sensitive paint (PSP) measurement technique. In addition, detailed film cooling effectiveness is acquired to quantify the parametric effect of blowing ratio and density ratio on a plane tip design. Increasing the blowing ratio and density ratio resulted in increased film cooling effectiveness at all injection scenarios. Injecting coolant on the PS and the tip surface also resulted in reduced leakage over the tip. The conclusions from this study will provide the gas turbine designer with additional insight on controlling different parameters and strategically placing the holes during the design process.


Author(s):  
JeongJu Kim ◽  
Wonjik Seo ◽  
Minho Bang ◽  
Seon Ho Kim ◽  
Seok Min Choi ◽  
...  

Film cooling effectiveness and heat transfer were measured in squealer tip configurations on the blade tip surface. Three different shelf squealer tip geometries were studied: conventional, vertical, and inclined. The experiment was carried out in a wind tunnel with an inlet mainstream Reynolds number, based on the axial chord length of the blade, of 140,000. The experiments were conducted in five blades in linear cascade with an averaged turbulence intensity of 8.5%. The film cooling effectiveness and heat transfer coefficient on the tip surface were obtained using the transient IR thermography technique. For the pressure side film cooling holes, averaging blowing ratios (M) of 1.0 and 2.0 were set. The results showed the film cooling effectiveness distributions on the tip surface. Owing to the mainstream, the cooling effect appeared after x/Cx = 0.15 and the film cooling effectiveness tended to increase toward downstream of the trailing edge. Additionally, the heat transfer distributions were investigated regarding the film cooling holes. In the presence of film cooling holes, the heat transfer distribution had more uniformity than without them on the pressure side. As the blowing ratio increased from 1 to 2, the heat transfer was decreased on the tip surface. The heat transfer ratio represented the change of heat transfer distribution with and without film cooling holes. Those of results were compared in three squealer tip geometries. The overall area-averaged net heat flux reduction (NHFR) levels on the tip surface were enhanced as the blowing ratio increased. The NHFR of the shelf squealer tip configurations was better than that with the conventional squealer tip.


Author(s):  
Onieluan Tamunobere ◽  
Sumanta Acharya

This is the first in a two-part series of an experimental film cooling study conducted on the tip of a turbine blade with a blade rotation speed of 1200 RPM. In this part of the study, the coolant is injected from the blade tip and pressure side (PS) holes, and the effect of the blowing ratio on the heat transfer coefficient and film cooling effectiveness of the blade tip is investigated. The blade has a tip clearance of 1.7% of the blade span and consists of a cut back squealer rim, two cylindrical tip holes and six shaped pressure side holes. The stator-rotor-stator test section is housed in a closed loop wind tunnel that allows for the performance of transient heat transfer tests. Measurements of the heat transfer coefficient and film cooling effectiveness are done on the blade tip using liquid crystal thermography. These measurements are reported for the no coolant case and for blowing ratios of 1.0, 1.5, 2.0, 3.0 and 4.0. The heat transfer results for the no coolant injection show a region of high heat transfer on the blade tip near the blade leading edge region as the incident flow impinges on that region. This region of high heat transfer extends and stretches on the tip as more coolant is introduced through the tip holes at higher blowing ratios. The cooling results show that increasing the blowing ratio increases the film cooling effectiveness. The tip film cooling profile is such that the tip coolant is pushed towards the blade suction side thereby providing better coverage in that region. The shift in coolant flow profile towards the blade suction side as opposed to the pressure side in stationary studies can primarily be attributed to the effects of the blade relative motion.


Author(s):  
S. Naik ◽  
J. Krueckels ◽  
M. Gritsch ◽  
M. Schnieder

This paper investigates the aerodynamic and film cooling effectiveness characteristics of a first stage turbine high lift guide vane and its corresponding downstream blade. The vane and blade geometrical profiles and operating conditions are representative of that normally found in a heavy-duty gas turbine. Both the vane and the blade airfoils consist of multi-row film cooling holes located at various axial positions along the airfoil chord. The film cooling holes are geometrically three-dimensional in shape and depending on the location on the airfoil; they can be either symmetrically fan shaped or non-symmetrically fan shaped. Additionally the film cooling holes can be either compounded or in-line with the external flow direction. Numerical studies and experimental investigations in a linear cascade have been conducted at vane and blade exit isentropic Mach number of 0.8. The influence of the coolant flow ejected from the film cooling holes has been investigated for both the vane and the blade profiles. For the nozzle guide vane, the measured film cooling effectiveness compared well with the predictions, especially on the pressure side. The suction side film cooling effectiveness, which consisted of two pre-throat film rows, proved very effective up-to the suction side trailing edge. For the blade, there was a reasonable comparison between the measured and predicted film cooling effectiveness. Again the blade pre-throat fan shaped cooling holes proved very effective up-to the suction side trailing edge. For the vane, the impact of varying the blowing ratios showed a strong variation in the film cooling effectiveness on the pressure side. However, on the blade, the effect of varying the blowing ratio had a greater impact on the suction side film effectiveness compared to the pressure side.


Author(s):  
Izhar Ullah ◽  
Sulaiman Alsaleem ◽  
Lesley Wright ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This work is an experimental study of film cooling effectiveness on a blade tip in a stationary, linear cascade. The cascade is mounted in a blowdown facility with controlled inlet and exit Mach numbers of 0.29 and 0.75, respectively. The free stream turbulence intensity is measured to be 13.5 % upstream of the blade's leading edge. A flat tip design is studied, having a tip gap of 1.6%. The blade tip is designed to have 15 shaped film cooling holes along the near-tip pressure side (PS) surface. Fifteen vertical film cooling holes are placed on the tip near the pressure side. The cooling holes are divided into a 2-zone plenum to locally maintain the desired blowing ratios based on the external pressure field. Two coolant injection scenarios are considered by injecting coolant through the tip holes only and both tip and PS surface holes together. The blowing ratio (M) and density ratio (DR) effects are studied by testing at blowing ratios of 0.5, 1.0, and 1.5 and three density ratios of 1.0, 1.5, and 2.0. Three different foreign gases are used to create density ratio effect. Over-tip flow leakage is also studied by measuring the static pressure distributions on the blade tip using the pressure sensitive paint measurement technique. In addition, detailed film cooling effectiveness and over-tip flow leakage is acquired to quantify the parametric effect of blowing ratio and density ratio on a plane tip.


2013 ◽  
Vol 136 (5) ◽  
Author(s):  
S. Naik ◽  
J. Krueckels ◽  
M. Gritsch ◽  
M. Schnieder

This paper investigates the aerodynamic and film cooling effectiveness characteristics of a first stage turbine high lift guide vane and its corresponding downstream blade. The vane and blade geometrical profiles and operating conditions are representative of that normally found in a heavy-duty gas turbine. Both the vane and the blade airfoils consist of multirow film cooling holes located at various axial positions along the airfoil chord. The film cooling holes are geometrically three-dimensional in shape and depending on the location on the airfoil, they can be either symmetrically fan shaped or nonsymmetrically fan shaped. Additionally the film cooling holes can be either compounded or in-line with the external flow direction. Numerical studies and experimental investigations in a linear cascade have been conducted at vane and blade exit isentropic Mach number of 0.8. The influence of the coolant flow ejected from the film cooling holes has been investigated for both the vane and the blade profiles. For the nozzle guide vane, the measured film cooling effectiveness compared well with the predictions, especially on the pressure side. The suction side film cooling effectiveness, which consisted of two prethroat film rows, proved very effective up to the suction side trailing edge. For the blade, there was a reasonable comparison between the measured and predicted film cooling effectiveness. Again the blade prethroat fan shaped cooling holes proved very effective up to the suction side trailing edge. For the vane, the impact of varying the blowing ratios showed a strong variation in the film cooling effectiveness on the pressure side. However, on the blade, the effect of varying the blowing ratio had a greater impact on the suction side film effectiveness compared to the pressure side.


2005 ◽  
Vol 127 (5) ◽  
pp. 521-530 ◽  
Author(s):  
Jaeyong Ahn ◽  
Shantanu Mhetras ◽  
Je-Chin Han

Effects of the presence of squealer, the locations of the film-cooling holes, and the tip-gap clearance on the film-cooling effectiveness were studied and compared to those for a plane (flat) tip. The film-cooling effectiveness distributions were measured on the blade tip using the pressure-sensitive paint technique. Air and nitrogen gas were used as the film-cooling gases, and the oxygen concentration distribution for each case was measured. The film-cooling effectiveness information was obtained from the difference of the oxygen concentration between air and nitrogen gas cases by applying the mass transfer analogy. Plane tip and squealer tip blades were used while the film-cooling holes were located (a) along the camber line on the tip or (b) along the tip of the pressure side. The average blowing ratio of the cooling gas was 0.5, 1.0, and 2.0. Tests were conducted with a stationary, five-bladed linear cascade in a blow-down facility. The free-stream Reynolds number, based on the axial chord length and the exit velocity, was 1,138,000, and the inlet and the exit Mach numbers were 0.25 and 0.6, respectively. Turbulence intensity level at the cascade inlet was 9.7%. All measurements were made at three different tip-gap clearances of 1%, 1.5%, and 2.5% of blade span. Results show that the locations of the film-cooling holes and the presence of squealer have significant effects on surface static pressure and film-cooling effectiveness, with film-cooling effectiveness increasing with increasing blowing ratio.


2014 ◽  
Vol 521 ◽  
pp. 104-107
Author(s):  
Ling Zhang ◽  
Quan Heng Jin ◽  
Da Fei Guo

The Realizable k-ε turbulence model was performed to investigate the film cooling effectiveness with different blowing ratio 1,1.5,2 and different density ratio 1,1.5,2.The results show that, cooling effectiveness increases with the augment of blowing ratio. On the pressure side, cooling effectiveness increases with the augment of density ratio. On the suction side, with higher density ratio the leading edge cooling increases, the middle section reduces, and the trailing edge cooling effectiveness increases first decreases.


Author(s):  
Yi Lu ◽  
Yinyi Hong ◽  
Zhirong Lin ◽  
Xin Yuan

Detailed film cooling effectiveness distributions were experimentally obtained on a turbine vane platform within a linear cascade. Testing was done in a large scale five-vane cascade with low freestream Renolds number condition 634,000 based on the axial chord length and the exit velocity. The detailed film-cooling effectiveness distributions on the platform were obtained using pressure sensitive paint technique. Two film-cooling hole configurations, cylindrical and fan-shaped, were used to cool the vane surface with two rows on pressure side, two rows on suction side and three rows on leading edge. For cylindrical holes, the blowing ratio of the coolant through the discrete cooling holes on pressure side and suction side ranged from 0.3 to 1.5 (based on the inlet mainstream velocity) while the blowing ratio ranging from 0.15 to 1.5 on leading edge; for fan-shaped holes, the four blowing ratios were 0.5, 1.0, 1.5 and 2.0. Results showed that average film-cooling effectiveness decreased with increasing blowing rate for the cylindrical holes, while the fan-shaped passage showed increased film-cooling effectiveness with increasing blowing ratio, indicating the fan-shaped cooling holes helped to improve film-cooling effectiveness by reducing overall jet liftoff. Fan-shaped holes improved average film-cooling effectiveness by 93.2%, 287.6% and 489.6% on pressure side, −4.1%, 27.9% and 78.2% on suction side over cylindrical holes at the blowing ratio of 0.5, 1.0 and 1.5 respectively. Numerical results were used to analyze the details of the flow and heat transfer on the cooling area with two turbulence models. Results demonstrated that tendency of the film cooling effectiveness distribution of numerical calculation and experimental measurement was generally consistent at different blowing ratio.


2009 ◽  
Vol 131 (3) ◽  
Author(s):  
Zhihong Gao ◽  
Diganta Narzary ◽  
Shantanu Mhetras ◽  
Je-Chin Han

The influence of incidence angle on film-cooling effectiveness is studied for a cutback squealer blade tip. Three incidence angles are investigated −0 deg at design condition and ±5 deg at off-design conditions. Based on mass transfer analogy, the film-cooling effectiveness is measured with pressure sensitive paint techniques. The film-cooling effectiveness distribution on the pressure side near tip region, squealer cavity floor, and squealer rim tip is presented for the three incidence angles at varying blowing ratios. The average blowing ratio is controlled to be 0.5, 1.0, 1.5, and 2.0. One row of shaped holes is provided along the pressure side just below the tip; two rows of cylindrical film-cooling holes are arranged on the blade tip in such a way that one row is offset to the suction side profile and the other row is along the camber line. The pressure side squealer rim wall is cut near the trailing edge to allow the accumulated coolant in the cavity to escape and cool the tip trailing edge. The internal coolant-supply passages of the squealer tipped blade are modeled similar to those in the GE-E3 rotor blade. Test is done in a five-blade linear cascade in a blow-down facility with a tip gap clearance of 1.5% of the blade span. The Mach number and turbulence intensity level at the cascade inlet were 0.23 and 9.7%, respectively. It is observed that the incidence angle affects the coolant jet direction on the pressure side near tip region and the blade tip. The film-cooling effectiveness distribution is also altered. The peak of laterally averaged effectiveness is shifted upstream or downstream depending on the off-design incidence angle. The film cooling effectiveness inside the tip cavity can increase by 25% with the positive incidence angle. However, in general, the overall area-averaged film-cooling effectiveness is not significantly changed by the incidence angles in the range of study.


Sign in / Sign up

Export Citation Format

Share Document