Cross-Verification of Thermal Characterization of a Microcooler

2007 ◽  
Vol 129 (2) ◽  
pp. 167-171 ◽  
Author(s):  
Zs. Kohári ◽  
Gy. Bognár ◽  
Gy. Horváth ◽  
A. Poppe ◽  
M. Rencz ◽  
...  

The thermal behavior of a microcooler has been investigated using two different measurement methods to verify their feasibility. On the one hand structure function derived from the thermal measurements was used, while on the other hand, characterization was done with a heat-flux sensor array. The measurement sample was a square nickel plate microcooler holding 128 microchannels in radial arrangement. In our previous studies it was attached to a power transistor which was used as a dissipator and a temperature sensor. The thermal transient response to a dissipation step of the transistor was recorded in the measurement. The measured transients (cooling curves) were transformed into structure functions from which the partial thermal resistance corresponding to the cooling assembly was identified. In the current study the measurement setup was completed by a heat-flux sensor inbetween the dissipator and the microcooler to be able to verify the results extracted via structure functions. In this way we could compare the heat-transfer coefficient (HTC) values obtained from the identified thermal resistances to those calculated directly from the measured heat-flux values. Good matching of the HTC values resulting from the two different methods was found.

2004 ◽  
Author(s):  
G. E. Sandoval-Romero ◽  
J. Hernandez-Cedillo ◽  
E. A. Martinez-Gomez ◽  
Augusto Garcia-Valenzuela ◽  
C. Sanchez-Perez ◽  
...  

2013 ◽  
Vol 378 ◽  
pp. 302-307 ◽  
Author(s):  
B. Azerou ◽  
B. Garnier ◽  
A. Lahmar

The measurement of thermal properties or internal or external boundary conditions requires temperature and heat flux data. Both information can be provided by heat flux sensors. The one consisting in measuring temperature at various locations within the wall and using inverse method to estimate wall temperature and heat flux is among those providing the lowest measurement bias for transient heat flux measurement. However, this very accurate sensor requires time consuming technical work for microthermocouples implementation and due to the welding, one cannot locate precisely the temperature measurement. The idea developed in this work is to replace the wire microthermocouples by thin film resistance temperature detectors deposited on polymer substrate in order to ease the fabrication and to increase the accuracy of heat flux sensor. As the deposited sensors are RTDs, a preliminary study is performed showing the effect of the metal as well as the processing conditions on the electrical resistivity and temperature coefficient of copper and aluminum thin film


Sensors ◽  
2010 ◽  
Vol 10 (7) ◽  
pp. 6594-6611 ◽  
Author(s):  
Sung-Ki Nam ◽  
Jung-Kyun Kim ◽  
Sung-Cheon Cho ◽  
Sun-Kyu Lee

2021 ◽  
Vol 91 (2) ◽  
pp. 240
Author(s):  
Ю.В. Добров ◽  
В.А. Лашков ◽  
И.Ч. Машек ◽  
А.В. Митяков ◽  
В.Ю. Митяков ◽  
...  

In this work we performed calibration of the gradient heat flux sensor made of bismuth single crystal. The value of the volt-watt sensitivity of the sensor is found and a data processing method based on the one-dimensional heat equation for a thin plate is presented. An experimental study of the heat flux on the frontal surface of the cylinder after a laser discharge was carried out. The data obtained as a result of the experiment were processed by the proposed method.


2007 ◽  
Vol 78 (5) ◽  
pp. 053501 ◽  
Author(s):  
Stefan Löhle ◽  
Jean-Luc Battaglia ◽  
Jean-Christophe Batsale ◽  
Olivier Enouf ◽  
Jimmy Dubard ◽  
...  

2015 ◽  
Vol 135 (8) ◽  
pp. 343-348
Author(s):  
Shinya Nakagawa ◽  
Masao Shimizu ◽  
Tsuyoshi Hamaguchi

Sign in / Sign up

Export Citation Format

Share Document