Cavitation Enhanced Heat Transfer in Microchannels

2006 ◽  
Vol 128 (12) ◽  
pp. 1293-1301 ◽  
Author(s):  
Brandon Schneider ◽  
Ali Koşar ◽  
Chih-Jung Kuo ◽  
Chandan Mishra ◽  
Gregory S. Cole ◽  
...  

Heat transfer has been investigated in the presence of hydrodynamic cavitation instigated by 20-μm wide inlet micro-orifices entrenched inside 227-μm hydraulic diameter microchannels. Average surface temperatures, heat transfer coefficients, and pressure drops have been obtained over effective heat fluxes ranging from 39 to 558W∕cm2 at mass flux of 1814kg∕m2s under noncavitating and three cavitating conditions. Significant heat transfer enhancement has been recorded during supercavitating flow conditions in comparison to noncavitating flows with minimal pressure drop penalty. Once supercavitating conditions were reached, no apparent heat transfer augmentation was detected with the reduction of the cavitation index. Visualization of the flow morphology and the heat transfer coefficient characteristics aided in the evaluation of the dominant heat transfer mechanism under various thermal-hydraulic conditions.

1986 ◽  
Vol 108 (3) ◽  
pp. 567-573 ◽  
Author(s):  
K. N. Agrawal ◽  
H. K. Varma ◽  
S. Lal

This work is an experimental investigation of heat transfer augmentation in a horizontal R-12 evaporator, continuing an earlier study [1] by the authors on swirl flow pressure drops. Twisted tapes were used to create swirl motion during the flow boiling inside an evaporator tube of 10 mm i.d. Average heat transfer coefficients have been determined for 60 runs corresponding to three heat fluxes, five mass velocities, and four twist ratios. Swirl flow heat transfer coefficients have been found, in general, to be greater than the corresponding plain flow values, but the degree of enhancement varies depending on the test conditions and the twist ratio of the inserted tape. An empirical correlation which predicts the average swirl flow heat transfer coefficients within ± 30 percent of the experimentally observed values has been successfully developed.


Author(s):  
Ann-Christin Fleer ◽  
Markus Richter ◽  
Roland Span

AbstractInvestigations of flow boiling in highly viscous fluids show that heat transfer mechanisms in such fluids are different from those in fluids of low viscosity like refrigerants or water. To gain a better understanding, a modified standard apparatus was developed; it was specifically designed for fluids of high viscosity up to 1000 Pa∙s and enables heat transfer measurements with a single horizontal test tube over a wide range of heat fluxes. Here, we present measurements of the heat transfer coefficient at pool boiling conditions in highly viscous binary mixtures of three different polydimethylsiloxanes (PDMS) and n-pentane, which is the volatile component in the mixture. Systematic measurements were carried out to investigate pool boiling in mixtures with a focus on the temperature, the viscosity of the non-volatile component and the fraction of the volatile component on the heat transfer coefficient. Furthermore, copper test tubes with polished and sanded surfaces were used to evaluate the influence of the surface structure on the heat transfer coefficient. The results show that viscosity and composition of the mixture have the strongest effect on the heat transfer coefficient in highly viscous mixtures, whereby the viscosity of the mixture depends on the base viscosity of the used PDMS, on the concentration of n-pentane in the mixture, and on the temperature. For nucleate boiling, the influence of the surface structure of the test tube is less pronounced than observed in boiling experiments with pure fluids of low viscosity, but the relative enhancement of the heat transfer coefficient is still significant. In particular for mixtures with high concentrations of the volatile component and at high pool temperature, heat transfer coefficients increase with heat flux until they reach a maximum. At further increased heat fluxes the heat transfer coefficients decrease again. Observed temperature differences between heating surface and pool are much larger than for boiling fluids with low viscosity. Temperature differences up to 137 K (for a mixture containing 5% n-pentane by mass at a heat flux of 13.6 kW/m2) were measured.


Author(s):  
O. Manca ◽  
S. Nardini ◽  
D. Ricci

Conventional sources of energy have been depleting at an alarming rate, which makes future sustainable development of energy use very difficult. Thus, heat transfer enhancement technology plays an important role and it has been widely applied to many applications as in refrigeration, automotive, process industry, solar energy heater, etc. Convective heat transfer can be enhanced passively by changing flow geometry, boundary conditions or by increasing thermal conductivity of the fluid. Another possibility for increasing heat transfer with gas is to employ extended surfaces. In this paper a numerical investigation is carried out on forced convection in circular tubes with septa heated by constant fluxes and characterized by different shapes. When gas flows in a tube, septa with one or more openings can be used as fins. Furthermore, when the openings are arranged to give a spiral motion around the cylinder axis wall-fluid contact area increases. As a consequence the presence of the septa may significantly augment pressure drops. The fluid is air and properties are function of temperature. Septa of the same material of the tube are introduced and several shapes and arrangements are analyzed as well as different Reynolds numbers, baffle spacings and heat fluxes applied on the external surface. The investigation is accomplished by means of the commercial code Fluent. A k-e turbulence model is used with enhanced wall treatment options. Results are presented in terms of temperature and velocity fields, local and average heat transfer coefficients, friction factors and pressure drops for different values of heat flux, Reynolds numbers and baffle spacings. The aim of this study is to find the shape and arrangement of septa such to give high heat transfer coefficients and low pressure drops.


2009 ◽  
Vol 131 (12) ◽  
Author(s):  
C.-J. Kuo ◽  
Y. Peles

Flow boiling was experimentally studied using coolant HFE-7000 for two types of parallel microchannels: a plain-wall microchannel and a microchannel with structured reentrant cavities on the side walls. Flow morphologies, boiling inceptions, heat transfer coefficients, and critical heat fluxes were obtained and studied for mass fluxes ranging from G=164 kg/m2 s to G=3025 kg/m2 s and mass qualities (energy definition) ranging from x=−0.25 to x=1. Comparisons of the performance of the enhanced and plain-wall microchannels were carried out. It was found that reentrant cavities were effective in reducing the superheat at the onset of nucleate boiling and increasing the heat transfer coefficient. However, they did not seem to increase the critical heat flux.


Energies ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 160 ◽  
Author(s):  
Bartosz Gil ◽  
Beata Fijałkowska

This paper investigates the nucleate boiling process of dimethyl ether and selected hydrocarbons. The main goal of this study is to measure the heat transfer coefficients of RE170, R600a, and R601, and to compare them with R134a. The experiments were carried out for heat fluxes up to 70 kW/m2. Experimental results have shown a typical trend that the heat transfer coefficient of flammable refrigerants increases as the heat flux increases. Among the tested fluids, the highest values of heat transfer coefficient were obtained for RE170. Available correlations describing this coefficient showed a deviation of up to 93%, as compared to the data obtained. The new correlation was developed by regression analysis taking into account dimensionless variables affecting the boiling process.


1974 ◽  
Vol 96 (2) ◽  
pp. 145-151 ◽  
Author(s):  
F. E. Megerlin ◽  
R. W. Murphy ◽  
A. E. Bergles

This paper summarizes the results of a study to determine the heat transfer and pressure drop characteristics of two types of tube inserts developed specifically for augmenting heat transfer and accommodating high heat fluxes. The best performing mesh-insert tubes exhibited heat transfer coefficients nine times the coefficients with empty tubes while brush-insert tubes had coefficients averaging five times the empty tube values, both comparisons being made at equal mass velocity. Both inserts produced very large pressure drops. Subcooled boiling curves and burnout points are presented; burnout heat fluxes are two to three times the empty tube values at equal mass velocity. For single-phase conditions and for burnout, the mesh and brush tubes have favorable performance characteristics, based on pumping power, which suggest use of these inserts in certain special cooling systems.


2002 ◽  
Vol 124 (6) ◽  
pp. 1034-1038 ◽  
Author(s):  
J. M. Crye ◽  
A. E. Ruggles ◽  
W. D. Pointer ◽  
D. K. Felde ◽  
P. A. Jallouk ◽  
...  

The heat transfer coefficient is inferred from measurements for mercury flowing in a channel of cross-section 2 mm×40 mm with flow velocities from 1 m/s to 4 m/s and heat fluxes from 192 kW/m2 to 1.14 MW/m2. Mercury bulk temperatures vary from 67°C to 143°C. Inferred heat transfer coefficients agree with open literature tube data when compared on a Nusselt versus. Peclet number plot, with Nusselt numbers examined from 8 to 17 and Peclet numbers examined from 790 to 3070.


Processes ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 830
Author(s):  
Viktor Vajc ◽  
Radek Šulc ◽  
Martin Dostál

Heat transfer coefficients were investigated for saturated nucleate pool boiling of binary mixtures of water and glycerin at atmospheric pressure in a wide range of concentrations and heat fluxes. Mixtures with water mass fractions from 100% to 40% were boiled on a horizontal flat copper surface at heat fluxes from about 25 up to 270kWm−2. Experiments were carried out by static and dynamic method of measurement. Results of the static method show that the impact of mixture effects on heat transfer coefficient cannot be neglected and ideal heat transfer coefficient has to be corrected for all investigated concentrations and heat fluxes. Experimental data are correlated with the empirical correlation α=0.59q0.714+0.130ωw with mean relative error of 6%. Taking mixture effects into account, data are also successfully correlated with the combination of Stephan and Abdelsalam (1980) and Schlünder (1982) correlations with mean relative error of about 15%. Recommended coefficients of Schlünder correlation C0=1 and βL=2×10−4ms−1 were found to be acceptable for all investigated mixtures. The dynamic method was developed for fast measurement of heat transfer coefficients at continuous change of composition of boiling mixture. The dynamic method was tested for water–glycerin mixtures with water mass fractions from 70% down to 35%. Results of the dynamic method were found to be comparable with the static method. For water–glycerin mixtures with higher water mass fractions, precise temperature measurements are needed.


1962 ◽  
Vol 84 (4) ◽  
pp. 365-371 ◽  
Author(s):  
H. S. Swenson ◽  
J. R. Carver ◽  
G. Szoeke

In large, subcritical pressure, once-through power boilers heat is transferred to steam and water mixtures ranging in steam quality from zero per cent at the bottom of the furnace to 100 per cent at the top. In order to provide design information for this type of boiler, heat-transfer coefficients for forced convection film boiling were determined for water at 3000 psia flowing upward in a vertical stainless-steel tube, AISI Type 304, having an inside diameter of 0.408 inches and a heated length of 6 feet. Heat fluxes ranged between 90,000 and 180,000 Btu/hr-sq ft and were obtained by electrical resistance heating of the tube. The operation of the experimental equipment was controlled so that nucleate boiling, transition boiling, and stable film boiling occurred simultaneously in different zones of the tube. The film boiling data were correlated with a modified form of the equation Nu = a a(Re)m(Pr)n using steam properties evaluated at inside surface temperature. Results of a second series of heat-transfer tests with tubes having a helical rib on the inside surface showed that nucleate boiling could be maintained to much higher steam qualities with that type of tube than with a smooth-bore tube.


Author(s):  
Todd M. Bandhauer ◽  
Taylor A. Bevis

The principle limit for achieving higher brightness of laser diode arrays is thermal management. State of the art laser diodes generate heat at fluxes in excess of 1 kW cm−2 on a plane parallel to the light emitting edge. As the laser diode bars are packed closer together, it becomes increasingly difficult to remove large amounts of heat in the diminishing space between neighboring diode bars. Thermal management of these diode arrays using conduction and natural convection is practically impossible, and, therefore, some form of forced convective cooling must be utilized. Cooling large arrays of laser diodes using single-phase convection heat transfer has been investigated for more than two decades by multiple investigators. Unfortunately, either large fluid temperature increases or very high flow velocities must be utilized to reject heat to a single phase fluid, and the practical threshold for single phase convective cooling of laser diodes appears to have been reached. In contrast, liquid-vapor phase change heat transport can occur with a negligible increase in temperature and, due to a high enthalpy of vaporization, at comparatively low mass flow rates. However, there have been no prior investigations at the conditions required for high brightness edge emitting laser diode arrays: >1 kW cm−2 and >10 kW cm−3. In the current investigation, flow boiling heat transfer at heat fluxes up to 1.1 kW cm−2 was studied in a microchannel heat sink with plurality of very small channels (45 × 200 microns) using R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio in the vicinity of the laser diode. To characterize the heat transfer performance, a test facility was constructed that enabled testing over a range of fluid saturation temperatures (15°C to 25°C). Due to the very small geometric features, significant heat spreading was observed, necessitating numerical methods to determine the average heat transfer coefficient from test data. This technique is crucial to accurately calculate the heat transfer coefficients for the current investigation, and it is shown that the analytical approach used by many previous investigations requires assumptions that are inadequate for the very small dimensions and heat fluxes observed in the present study. During the tests, the calculated outlet vapor quality exceeded 0.6 and the base heat flux reached a maximum of 1.1 kW cm−2. The resulting experimental heat transfer coefficients are found to be as large a 58.1 kW m−2 K−1 with an average uncertainty of ±11.1%, which includes uncertainty from all measured and calculated values, required assumptions, and geometric discretization error from meshing.


Sign in / Sign up

Export Citation Format

Share Document