Asymptotically Consistent Numerical Approximation of Hemolysis

2006 ◽  
Vol 128 (5) ◽  
pp. 688-696 ◽  
Author(s):  
Marie-Isabelle Farinas ◽  
André Garon ◽  
David Lacasse ◽  
Donatien N’dri

In a previous communication, we have proposed a numerical framework for the prediction of in vitro hemolysis indices in the preselection and optimization of medical devices. This numerical methodology is based on a novel interpretation of Giersiepen-Wurzinger blood damage correlation as a volume integration of a damage function over the computational domain. We now propose an improvement of this approach based on a hyperbolic equation of blood damage that is asymptotically consistent. Consequently, while the proposed correction has yet to be proven experimentally, it has the potential to numerically predict more realistic red blood cell destruction in the case of in vitro experiments. We also investigate the appropriate computation of the shear stress scalar of the damage fraction model. Finally, we assess the validity of this consistent approach with an analytical example and with some 3D examples.

Author(s):  
Yertay Mendygarin ◽  
Luis R. Rojas-Solórzano ◽  
Nurassyl Kussaiyn ◽  
Rakhim Supiyev ◽  
Mansur Zhussupbekov

Cardiovascular Diseases, the common name for various Heart Diseases, are responsible for nearly 17.3 million deaths annually and remain the leading global cause of death in the world. It is estimated that this number will grow to more than 23.6 million by 2030, with almost 80% of all cases taking place in low and middle income countries. Surgical treatment of these diseases involves the use of blood-wetted devices, whose relatively recent development has given rise to numerous possibilities for design improvements. However, blood can be damaged when flowing through these devices due to the lack of biocompatibility of surrounding walls, thermal and osmotic effects and most prominently, due to the excessive exposure of blood cells to shear stress for prolonged periods of time. This extended exposure may lead to a rupture of membrane of red blood cells, resulting in a release of hemoglobin into the blood plasma, in a process called hemolysis. Moreover, exposure of platelets to high shear stresses can increase the likelihood of thrombosis. Therefore, regions of high shear stress and residence time of blood cells must be considered thoroughly during the design of blood-contacting devices. Though laboratory tests are vital for design improvements, in-vitro experiments have proven to be costly, time-intensive and ethically controversial. On the other hand, simulating blood behavior using Computational Fluid Dynamics (CFD) is considered to be an inexpensive and promising tool to help predicting blood damage in complex flows. Nevertheless, current state-of-the-art CFD models of blood flow to predict hemolysis are still far from being fully reliable and accurate for design purposes. Previous work have demonstrated that prediction of hemolysis can be dramatically improved when using a multiphase (i.e., phases are plasma, red blood cells and platelets) model of the blood instead of assuming the blood as a homogeneous mixture. Nonetheless, the accurate determination of how the cells segregate becomes the critical issue in reaching a truthful prediction of blood damage. Therefore, the attempt of this study is to develop and validate a numerical model based on Granular Kinetic Theory (GKT) for solid phases (i.e., cells treated as particles) that provides an improved prediction of blood cells segregation within the flow in a microtube. Simulations were based on finite volume method using Eulerian-Eulerian modeling for treatment of three-phase (liquid-red blood cells and platelets) flow including the GKT to deal with viscous properties of the solid phases. GKT proved to be a good model to predict particle concentration and pressure drop by taking into account the contribution of collisional, kinetic and frictional effects in the stress tensor of the segregated solid phases. Preliminary results show that the improved segregated model leads to a better prediction of spatial distribution of blood cells. Simulations were performed using ANSYS FLUENT platform.


1991 ◽  
Vol 14 (11) ◽  
pp. 716-720 ◽  
Author(s):  
S. Einav ◽  
H. Reul ◽  
G. Rau ◽  
D. Elad

Blood flowing through a prosthetic heart valve can be damaged by flow-induced shear forces. Fluid dynamics variables and geometric factors play an important role in the evaluation of shear-stress-related blood damage. Central-flow prosthetic valves have been considered as an optimal replacement for mechanical and biological valves. Recently it was shown that shear stress distribution along the surface of a polyurethane cusp reaches values that can damage the blood elements. A mathematical model correlating the effects of shear stresses on blood corpuscles with clinical findings was employed in vitro. The model can be applied to the effects of blood-surface interaction and is of clinical relevance


2021 ◽  
pp. 039139882110035
Author(s):  
Xu Mei ◽  
Min Zhong ◽  
Wanning Ge ◽  
Liudi Zhang

Non-physiological shear stress in Ventricular Assist Device (VAD) is considered to be an important trigger of blood damage, which has become the biggest shackle for clinical application. The researches on blood damage in literature were limited to qualitative but did not make much quantitative analysis. The purpose of this study was to investigate the quantitative influence of two flow-dependent parameters: shear stress (rotational speed) and exposure time on the shear-induced damage of red blood cells and von Willebrand Factor (vWF). A vortex blood-shearing platform was constructed to conduct in vitro experiments. Free hemoglobin assay and vWF molecular weight analysis were then performed on the sheared blood samples. MATLAB was used for regression fitting of original experimental data. The quantitative correlations between the hemolysis index, the degradation of high molecular weight vWF and the two flow-dependent parameters were found both following the power law model. The mathematic models indicated that the sensitivity of blood damage on red blood cells and vWF to exposure time was both greater than that of shear stress. Besides, the damage of vWF was more serious than that of red blood cells at the same flow condition. The models could be used to predict blood damage in blood-contacting medical devices, especially for the slow even stagnant blood flow regions in VAD, thus may provide useful guidance for VAD development and improvement. It also indicated that the vortex platform can be used to study the law of blood damage for the simple structure and easy operation.


Author(s):  
Lasse Johannes Strudthoff ◽  
Hanna Lüken ◽  
Sebastian Victor Jansen ◽  
Jan Petran ◽  
Peter Schlanstein ◽  
...  

Extracorporeal membrane oxygenation (ECMO) is an established rescue therapy for patients with chronic respiratory failure waiting for lung transplantation (LTx). The therapy inherent immobilization may result in fatigue, consecutive deteriorated prognosis and even lost eligibility for transplantation. We conducted a feasibility study on a novel system designed for the deployment of a mobile ECMO device, enabling physical exercise of awake patients prior to LTx. The system comprises a novel mobile oxygenator with a directly connected blood pump, a double lumen cannula, gas blender and supply, as well as control, and energy management. In-vitro experiments included tests regarding performance, efficiency, and blood damage. A reduced system was tested in vivo for feasibility using a novel large animal model. Six anesthetized pigs were first positioned in supine position, followed by a 45° angle, simulating an upright position of the patients. We monitored performance and vital parameters. All in-vitro experiments showed good performance for the respective subsystems and the integrated system. The acute invivo trials of 8h duration confirmed the results. The novel mobile ECMO-system enables adequate oxygenation and decarboxylation sufficient for, e.g., physical exercise of designated LTx-recipients. These results are promising and suggest further preclinical studies on safety and efficacy to facilitate translation into clinical application.


Author(s):  
J. Metuzals

It has been demonstrated that the neurofibrillary tangles in biopsies of Alzheimer patients, composed of typical paired helical filaments (PHF), consist also of typical neurofilaments (NF) and 15nm wide filaments. Close structural relationships, and even continuity between NF and PHF, have been observed. In this paper, such relationships are investigated from the standpoint that the PHF are formed through posttranslational modifications of NF. To investigate the validity of the posttranslational modification hypothesis of PHF formation, we have identified in thin sections from frontal lobe biopsies of Alzheimer patients all existing conformations of NF and PHF and ordered these conformations in a hypothetical sequence. However, only experiments with animal model preparations will prove or disprove the validity of the interpretations of static structural observations made on patients. For this purpose, the results of in vitro experiments with the squid giant axon preparations are compared with those obtained from human patients. This approach is essential in discovering etiological factors of Alzheimer's disease and its early diagnosis.


1998 ◽  
Vol 80 (09) ◽  
pp. 437-442 ◽  
Author(s):  
I. Hioki ◽  
K. Onoda ◽  
T. Shimono ◽  
H. Shimpo ◽  
K. Tanaka ◽  
...  

SummaryAlterations in platelet aggregability may play a role in the pathogenesis of qualitative platelet defects associated with cardiopulmonary bypass (CPB). We circulated fresh heparinized whole blood through tubing sets coated with heparin (C group, n = 10) and through non-coated sets (N group, n = 10) as a simulated CPB circuit. Shear stress (108 dyne/cm2)-induced platelet aggregation (hSIPA), plasma von Willebrand factor (vWF) activity and platelet glycoprotein (GP) Ib expression were measured, before, during, and after this in vitro set up of circulation. In the two groups, the extent of hSIPA significantly decreased during circulation and was partially restored after circulation. Decreases in the extent of hSIPA were significantly less with use of heparin-coated circuits. There was an equivalent reduction in plasma vWF activity, in the two groups. Expression of platelet surface GP Ib decreased significantly during circulation and recovered after circulation. Reduction of surface GP Ib expression during circulation was significantly less in the C group than that in the N group. Decrease in surface GP Ib expression correlated (r = 0.88 in either group) with the magnitude of hSIPA, in the two groups. The progressive removal of surface GP Ib was mainly attributed to redistribution of GP Ib from the membrane skeleton into the cytoskeleton. Our observations suggest that use of heparin-coated circuits partly blocks the reduction of hSIPA, as a result of a lesser degree of redistribution of GP Ib.


Sign in / Sign up

Export Citation Format

Share Document