Experimental Investigation of Local Heat Transfer Distribution on Smooth and Roughened Surfaces Under an Array of Angled Impinging Jets

2004 ◽  
Vol 127 (3) ◽  
pp. 532-544 ◽  
Author(s):  
Lamyaa A. El-Gabry ◽  
Deborah A. Kaminski

Measurements of the local heat transfer distribution on smooth and roughened surfaces under an array of angled impinging jets are presented. The test rig is designed to simulate impingement with crossflow in one direction. Jet angle is varied between 30, 60, and 90deg as measured from the target surface, which is either smooth or randomly roughened. Liquid crystal video thermography is used to capture surface temperature data at five different jet Reynolds numbers ranging between 15,000 and 35,000. The effect of jet angle, Reynolds number, gap, and surface roughness on heat transfer and pressure loss is determined along with the various interactions among these parameters.

2001 ◽  
Author(s):  
Lamyaa A. El-Gabry ◽  
Deborah A. Kaminski

Abstract Measurements of the local heat transfer distribution on smooth and roughened surfaces under an array of angled impinging jets are presented. The test rig is designed to simulate impingement with cross-flow in one direction which is a common method for cooling gas turbine components such as the combustion liner. Jet angle is varied between 30, 60, and 90 degrees as measured from the impingement surface, which is either smooth or randomly roughened. Liquid crystal video thermography is used to capture surface temperature data at five different jet Reynolds numbers ranging between 15,000 and 35,000. The effect of jet angle, Reynolds number, gap, and surface roughness on heat transfer efficiency and pressure loss is determined along with the various interactions among these parameters. Peak heat transfer coefficients for the range of Reynolds number from 15,000 to 35,000 are highest for orthogonal jets impinging on roughened surface; peak Nu values for this configuration ranged from 88 to 165 depending on Reynolds number. The ratio of peak to average Nu is lowest for 30-degree jets impinging on roughened surfaces. It is often desirable to minimize this ratio in order to decrease thermal gradients, which could lead to thermal fatigue. High thermal stress can significantly reduce the useful life of engineering components and machinery. Peak heat transfer coefficients decay in the cross-flow direction by close to 24% over a dimensionless length of 20. The decrease of spanwise average Nu in the crossflow direction is lowest for the case of 30-degree jets impinging on a roughened surface where the decrease was less than 3%. The decrease is greatest for 30-degree jet impingement on a smooth surface where the stagnation point Nu decreased by more than 23% for some Reynolds numbers.


1980 ◽  
Vol 102 (4) ◽  
pp. 994-999 ◽  
Author(s):  
B. R. Hollworth ◽  
L. Dagan

Measurements of average convective heat transfer are reported for square arrays of impinging air jets. The target plate on which the jets impinge is perforated so that spent air is withdrawn through the plate rather than at one or more edges of the array, as is usually the case in such investigations. Jet holes and vent holes had the same diameters, but the spacing of the jet holes was twice that of the vent holes. This information is especially relevent to the design of hybrid cooling configurations, in which a surface is cooled by the combined mechanisms of impingement and transpiration. Tests were conducted for both inline arrangements (with a vent hole opposite each jet orifice) and for staggered arrangements; and the latter always yielded higher average heat transfer. The degradation of performance of inline arrays was most pronounced when the clearance between the jet orifice plate and the target plate was small. Under these conditions, a significant portion of each jet flows directly out through the opposing vent without “scrubbing” the target surface. Arrays with staggered vent holes yield heat transfer rates consistently higher (sometimes by as much as 35 percent) than the same jet array with edge venting. The authors attribute the superior performance of the former geometry to high local heat transfer due to boundary layer suction in the vicinities of the vent holes.


1978 ◽  
Vol 100 (2) ◽  
pp. 352-357 ◽  
Author(s):  
B. R. Hollworth ◽  
R. D. Berry

Local and average convective heat transfer coefficients were measured for arrays of widely spaced impinging air jets and correlated in terms of system geometry, air flow, and fluid properties. The configurations were square arrays of circular turbulent jets (spaced from 10–25 diameters apart) incident upon a flat isothermal target surface. Independent parameters were varied over ranges generally corresponding to gas turbine cooling applications. Local heat transfer coefficients were influenced by interference from neighboring jets only when the target plate and the jet orifice plate were less than five jet diameters apart. Average heat transfer coefficients were nearly equal for all the arrays tested as long as the coolant flow per unit area of target surface was held constant. In fact, there was a tendency for the more widely spaced configurations to produce slightly higher average heat transfer under such conditions.


1985 ◽  
Vol 107 (4) ◽  
pp. 910-915 ◽  
Author(s):  
B. R. Hollworth ◽  
L. R. Gero

Convective heat transfer was measured for a heated axisymmetric air jet impinging on a flat surface. It was found that the local heat transfer coefficient does not depend explicitly upon the temperature mismatch between the jet fluid and the ambient fluid if the convection coefficient is defined in terms of the difference between the local recovery temperature and target surface temperature. In fact, profiles of local heat transfer coefficients defined in this manner were found to be identical to those measured for isothermal impinging jets.


Author(s):  
Zhuang Wu ◽  
Hui-ren Zhu ◽  
Cun-liang Liu ◽  
Lin Li ◽  
Qiang Gao ◽  
...  

Abstract The numerical investigation of the flow and heat transfer characteristics from arrays of impinging jets with the roughed target surface is presented in this paper. Three novel streamlined roughness elements are proposed: similar round protuberance, similar trapezoidal straight rib, and similar trapezoidal curved rib. The jet Reynolds number ranges from 15000 to 30000, the protuberance height is h/H = 0.36, the rib height is h/H = 0.3, 0.5, and 0.7 respectively. The results show that the protuberance can shorten the nozzle to the stagnation point distance, increasing the heat transfer at the stagnation point by nearly 40%. The rib has a remarkable effect of guiding the flow in span-wise direction and away from the target surface, weakening the cross-flow effect. The straight rib gets a better guidance performance, the curved rib provides a larger surface area. An appropriate increase of rib height can improve local heat transfer, continuing to increase mainly enlarge heat transfer area. The decent aerodynamic shape decreases the flow discharge coefficient by only 2% at the rib height of 0.3H.


1983 ◽  
Vol 105 (2) ◽  
pp. 393-402 ◽  
Author(s):  
B. R. Hollworth ◽  
G. Lehmann ◽  
J. Rosiczkowski

An extensive study was conducted to determine the heat transfer characteristics of arrays of turbulent air jets impinging on perforated target surfaces. Spent air was withdrawn through vent holes on the surface, rather than along one or more of its edges, as had been done in all previous investigations. An earlier publication presented average heat transfer data for such systems; this paper gives results of comprehensive measurements of local heat transfer. Also given are the results of flow visualization studies, and an approximate mathematical model which predicts distributions of local heat transfer which agree satisfactorily with test data.


1967 ◽  
Vol 89 (2) ◽  
pp. 163-167 ◽  
Author(s):  
E. G. Filetti ◽  
W. M. Kays

Experimental data are presented for local heat transfer rates near the entrance to a flat duct in which there is an abrupt symmetrical enlargement in flow cross section. Two enlargement area ratios are considered, and Reynolds numbers, based on duct hydraulic diameter, varied from 70,000 to 205,000. It is found that such a flow is characterized by a long stall on one side and a short stall on the other. Maximum heat transfer occurs in both cases at the point of reattachment, followed by a decay toward the values for fully developed duct flow. Empirical equations are given for the Nusselt number at the reattachment point, correlated as functions of duct Reynolds number and enlargement ratio.


2009 ◽  
Vol 131 (7) ◽  
Author(s):  
Akhilesh P. Rallabandi ◽  
Huitao Yang ◽  
Je-Chin Han

Systematic experiments are conducted to measure heat transfer enhancement and pressure loss characteristics on a square channel (simulating a gas turbine blade cooling passage) with two opposite surfaces roughened by 45 deg parallel ribs. Copper plates fitted with a silicone heater and instrumented with thermocouples are used to measure regionally averaged local heat transfer coefficients. Reynolds numbers studied in the channel range from 30,000 to 400,000. The rib height (e) to hydraulic diameter (D) ratio ranges from 0.1 to 0.18. The rib spacing (p) to height ratio (p/e) ranges from 5 to 10. Results show higher heat transfer coefficients at smaller values of p/e and larger values of e/D, though at the cost of higher friction losses. Results also indicate that the thermal performance of the ribbed channel falls with increasing Reynolds numbers. Correlations predicting Nusselt number (Nu) and friction factor (f¯) as a function of p/e, e/D, and Re are developed. Also developed are correlations for R and G (friction and heat transfer roughness functions, respectively) as a function of the roughness Reynolds number (e+), p/e, and e/D.