Effect of the Location and the Properties of Thermostatic Expansion Valve Sensor Bulb on the Stability of a Refrigeration System

2005 ◽  
Vol 127 (1) ◽  
pp. 85-94 ◽  
Author(s):  
Veerendra Mulay ◽  
Amit Kulkarni ◽  
Dereje Agonafer ◽  
Roger Schmidt

The combination of increased power dissipation and increased packaging density has led to substantial increases in chip and module heat flux in high-end computers. The challenge has been to limit the rise in chip temperature. In the past, virtually all commercial computers were designed to operate at temperatures above the ambient. However, researchers have identified the advantages of operating electronics at low temperatures. The primary purpose of low-temperature cooling using a vapor compression system are faster switching times of semiconductor devices, increased circuit speed due to lower electrical resistance of interconnecting materials, and a reduction in thermally induced failures of devices and components. Achievable performance improvements range from 1% to 3% for every 10°C lower transistor temperature, depending on the doping characteristics of the chip. The current research focuses on IBM’s mainframe, which uses a conventional refrigeration system to maintain chip temperatures below that of comparable air-cooled systems, but well above cryogenic temperatures. Although performance has been the key driver in the use of this technology, the second major reason for designing a system with low-temperature cooling is the improvement achieved in reliability to counteract detrimental effects, which rise as technology is pushed to the extremes. A mathematical model is developed to determine the time constant for an expansion valve sensor bulb. This time constant varies with variation in the thermophysical properties of the sensor element; that is, bulb size and bulb liquid. An experimental bench is built to study the effect of variation of evaporator outlet superheat on system performance. The heat load is varied from no load to full load (1 KW) to find out the system response at various loads. Experimental investigation is also done to see how the changes in thermophysical properties of the liquid in the sensor bulb of the expansion valve affect the overall system performance. Different types of thermostatic expansion valves are tested to investigate that bulb size, bulb constant, and bulb location have significant effects on the behavior of the system. Thermal resistance between the bulb and evaporator return line can considerably affect the system stability, and by increasing the thermal resistance, the stability can be further increased.

Author(s):  
Veerendra Mulay ◽  
Dereje Agonafer ◽  
Roger Schmidt

The combination of increased power dissipation and increased packaging density has led to substantial increases in chip and module heat flux in high-end computers. The challenge has been to limit the rise in chip temperature. In the past virtually all-commercial computers were designed to operate at temperatures above the ambient. However researchers have identified the advantages of operating electronics at low temperatures. The primary purpose of low temperature cooling using vapor compression system are faster switching times of semiconductor devices, increased circuit speed due to lower electrical resistance of interconnecting materials, and a reduction in thermally induced failures of devices and components. Achievable performance improvements range from 1 to 3% for every 10°C lower transistor temperature, depending on the doping characteristics of the chip. The current research focuses on IBM’s mainframe, which uses a conventional refrigeration system to maintain chip temperatures below that of comparable air-cooled systems, but well above cryogenic temperatures. Although performance has been the key driver in the use of this technology, the second major reason for designing a system with low temperature cooling is the improvement achieved in reliability to counteract detrimental effects, which rise as technology is pushed to the extremes. A mathematical model is developed to determine the time constant for expansion valve sensor blub. This time constant varies with variation in thermo-physical properties of sensor element that is bulb size and blub liquid. An experimental bench is built to study the effect of variation of evaporator outlet superheat on system performance. The heat load is varied from no load to full load (1KW) to find out the system response at various loads. Experimental investigation is also done to see how the changes in thermo-physical properties of the liquid in sensor bulb of expansion valve affect the overall system performance. Different types of thermostatic expansion valves are tested to investigate that bulb size; bulb constant and bulb location have significant effect on the behavior of the system. Thermal resistance between the bulb and evaporator return line can considerably affect the system stability and by increasing the thermal resistance, the stability can be further increased.


Author(s):  
Amit Kulkarni ◽  
Dereje Agonafer ◽  
Roger Schmidt

The combination of increased power dissipation and increased packaging density has led to substantial increases in chip and module heat flux in high-end computers. The challenge has been to limit the rise in chip temperature. In the past virtually all-commercial computers were designed to operate at temperatures above the ambient. However researchers have identified the advantages of operating electronics at low temperatures. The current research focuses on IBM’s mainframe, which uses a conventional refrigeration system to maintain chip temperatures below that of comparable air-cooled systems, but well above cryogenic temperatures. An experimental bench was built to study the effect of variation of evaporator outlet superheat on system performance. Three different types of thermostatic expansion valves were tested in order to verify that the bulb size and bulb location have significant effect on the transient behavior of the system. Bulbs of each of the three thermostatic expansion valves were mounted at five different locations on the suction line. It was observed that the overall system stability increases as we move closer to the evaporator exit. It was also observed that there exists a region in the suction line at which the superheat variation is the least and placing the bulb at this region gives maximum stable operation of the system. This region can be defined as the minimum stable superheat point. Tests were conducted at five different load conditions 1000W, 750W, 500W, 250W and no load condition. It was observed that the system was the most stable at full load condition for all three types of valves and system stability consistently decreased as the load was decreased.


2013 ◽  
Vol 385-386 ◽  
pp. 233-236
Author(s):  
Qing Jiang Liu ◽  
Zeng Zhi Yuan ◽  
Jin Ting Sun ◽  
Fang Han

In order to improve refrigeration system stability and efficiency of the low pressure difference between thermostatic expansion valve, it is researched that the refrigeration system is the refrigerate capacity of the HSN7471-75 compressors. The system performance is analyzed and compared in the case of with and without refrigerant pumps. The results indicate that the COP of the refrigeration system with a pump can increase 31%. The reliability of system is also improved.


2017 ◽  
Vol 139 (4) ◽  
Author(s):  
Samuel F. Asokanthan ◽  
Soroush Arghavan ◽  
Mohamed Bognash

Effect of stochastic fluctuations in angular velocity on the stability of two degrees-of-freedom ring-type microelectromechanical systems (MEMS) gyroscopes is investigated. The governing stochastic differential equations (SDEs) are discretized using the higher-order Milstein scheme in order to numerically predict the system response assuming the fluctuations to be white noise. Simulations via Euler scheme as well as a measure of largest Lyapunov exponents (LLEs) are employed for validation purposes due to lack of similar analytical or experimental data. The response of the gyroscope under different noise fluctuation magnitudes has been computed to ascertain the stability behavior of the system. External noise that affect the gyroscope dynamic behavior typically results from environment factors and the nature of the system operation can be exerted on the system at any frequency range depending on the source. Hence, a parametric study is performed to assess the noise intensity stability threshold for a number of damping ratio values. The stability investigation predicts the form of threshold fluctuation intensity dependence on damping ratio. Under typical gyroscope operating conditions, nominal input angular velocity magnitude and mass mismatch appear to have minimal influence on system stability.


2014 ◽  
Vol 556-562 ◽  
pp. 907-911
Author(s):  
Chang Wei He ◽  
Meng Zhang ◽  
Xiao Ping Jia ◽  
Yuan Liu

In the paper, the design scheme of the new cold store is proposed firstly, with the consideration of the latest technology application and the convenience and maneuverability of practical teaching. Then the refrigeration system is designed based on the calculation of the heat load of the cold store. The suited components such as compressor, evaporator, condenser and expansion valve are selected and the electrical system is designed. After that the whole unit is installed and adjusted to make sure that the installation is propitious to improve the system performance and convenient for training. Finally the thermal performance of the new cold store system is tested and compared with the old system test. The result shows that the matching of the new refrigeration system is reasonable and the new cold store is up to the mustard. With the help of training on the cold store, the students will meet the essential requirements of STCW 78/95 convention on application and management of the marine cold store.


2013 ◽  
Vol 641-642 ◽  
pp. 117-122
Author(s):  
Hai Tao Wang

Under different Electronic Expansion Valve (EXV)opening degree at the fixing frequency of 50hz of the compressor,we had test the system performance. When the cooling refrigerant influence to the PV module and the heating air influence to the collector/evaporator reached the balance,the photoelectric efficiency achieved the maximum.When the EXV opening degree fixing, with the raising of the solar radiation, the compressor power values appeared oscillation,and the oscillation was especially evident when the EXV at the maximum opening degree. So we put forward the PV/T-SAHP system stability principle.At the same time,we found that the key of the PV/T-SAHP research is to discover the relation between the solar radiation and the superheat of collector/evaporator.


2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Xiangsheng Liu ◽  
Lin Ren ◽  
Yuanyuan Yang ◽  
Jun He ◽  
Zhengxin Zhou

In terms of the instability of the full-order observer for the induction motor in the low-speed regenerative mode, the low-speed unstable region which leads to the extension of the commissioning cycle cannot be eliminated by the traditional adaptive law which aims at good system performance. It is proposed that the feedback gain matrix can control both the unstable region and the system performance both. To make a trade-off between the stability and performance by designing the feedback gain matrix is still an open problem. To solve this problem, first we analyze the cause of instability and derive constraints to ensure system stability by establishing a transfer function of the adaptive observing system for the speed. Then, with the derived constraints as the design criteria for the feedback gain matrix, a control strategy combining the weighted adaptive law with the improved feedback gain matrix is proposed to improve the stability at low speed. Finally, by comparing the traditional control strategy with the proposed control strategy through simulations and experiments, we show that the proposed control strategy achieves better performance with higher stability.


2011 ◽  
Vol 383-390 ◽  
pp. 2276-2279
Author(s):  
Feng Juan Qu ◽  
Hui Zhao ◽  
Quan Bo Yuan

Currently in various fields systems are widely used. With the increasing of visitors, the number of concurrent processes raise as System response. In order to ensure system stability for business support, this article analyses data management strategy, database design strategy, application server design strategy, web server design strategy, and implements the enhancing system performance.


2021 ◽  
Vol 8 ◽  
Author(s):  
Tao Wang ◽  
Chunyan Rong ◽  
Shuai Tang ◽  
Yinqiu Hong

An integrated energy system is a promising approach to synthesize various forms of energy, where cooperative control is indispensable for stable and efficient operation. During the information exchange of cooperative distributed secondary control (DSC) in an integrated energy system, the effect of time delays on system performance cannot be ignored, which mainly consist of input delays and communication delays. Compared with most of the existing literature which only address DSC considering communication delays, this paper investigates the stability robustness of an integrated energy system in the case of both input and communication delays. First, the impacts of input and communication delays on DSC are analyzed based on the Gerschgorin theorem and Nyquist criterion, where the system stability is principally dependent on input delays while has little correlation with communication delays and the inconsistency of the two delays may result in steady-state deviation. Then, on the assumption of identical input and communication delays, a closed-loop small-signal model equipped with a distributed secondary controller is established for stability analysis and the delay-dependent criteria are formulated to determine the stability margin of the system based on critical characteristic root tracking. By a series of trial declarations, the delay margins with regard to different controller gains are determined and the qualitative relationship between delay margins and controller gains can be utilized to guide the controller design for improved system performance. The effectiveness of the theoretical results is verified by case studies on a test system.


Sign in / Sign up

Export Citation Format

Share Document