End Effects in Prestrained Plates Under Compression

2004 ◽  
Vol 71 (6) ◽  
pp. 816-824 ◽  
Author(s):  
B. Karp

The decay of end perturbations imposed on a rectangular plate subjected to compression is investigated in the context of plane-strain incremental finite elasticity. A separation of variables in the eigenfunction formulation is used for the perturbed field within the plate. Numerical results for the leading decay exponent are given for four rubbers: three compressible and one incompressible. It was found that the lowest decay rate is governed by a symmetric field that exhibits different patterns of dependence on the prestrain for compressible and for nearly incompressible solids. Compressible solids are characterized by low sensitivity of the decay rate to prestrain level up to moderate compression, beyond which an abrupt decrease of decay rate brings it to zero. Nearly incompressible solids, on the other hand, expose a different pattern involving interchange of modes with no decrease of decay rate to zero. Both patterns show that the decay rate obtained from linear elastic analysis can be considered as a good approximation for a prebuckled, slightly compressed plate, which is long enough in comparison to its width. Along with decaying modes, the eigenfunction expansion generates a nondecaying antisymmetric mode corresponding to buckling of the plate. Asymptotic expansion of that nondecaying mode near the stress free state predicts buckling according to the classical Euler formula. A consistent interpretation of end effects in the presence of a nondecaying mode is given.

2002 ◽  
Vol 69 (4) ◽  
pp. 515-520 ◽  
Author(s):  
B. Karp ◽  
D. Durban

Decay of end perturbations imposed on a prestrained semi-infinite rectangular plate is investigated in the context of plane-strain incremental finite elasticity. A separation of variables eigenfunction formulation is used for the perturbed field within the plate. Numerical results for the leading decay exponent are given for three hyperelastic materials with various boundary conditions at the long faces of the plate. The study exposes a considerable sensitivity of axial decay rates to boundary data, to initial strain and to constitutive behavior. It is suggested that the results are relevant to the applicability of Saint-Venant’s principle even though the eigenfunctions are not always self-equilibrating.


2011 ◽  
Vol 64 (2) ◽  
Author(s):  
B. Karp ◽  
D. Durban

Research studies aiming at examination and formulation of a dynamic analog to Saint-Venant’s principle (DSVP) are critically reviewed. Article concentrates on isotropic homogeneous linear elastic response over a range of structural geometries including waveguides, with either free or constrained lateral surfaces, half space, wedges and cones. Nearly 140 DSVP related references are covered starting with early ideas by Boley. A special chapter is dedicated to available experimental work on end effects and decay rate in dynamically excited structures. Current thinking on possible versions of DSVP is classified into several categories, one of which, the dynamic equivalence, is compatible with much of known experimental data and has been tacitly applied at various engineering situations. That observation provides inspiring ground for renewed interest in both practical and theoretical aspects of DSVP.


Author(s):  
Murray Vernon King ◽  
Donald F. Parsons

Effective application of the high-voltage electron microscope to a wide variety of biological studies has been restricted by the radiation sensitivity of biological systems. The problem of radiation damage has been recognized as a serious factor influencing the amount of information attainable from biological specimens in electron microscopy at conventional voltages around 100 kV. The problem proves to be even more severe at higher voltages around 1 MV. In this range, the problem is the relatively low sensitivity of the existing recording media, which entails inordinately long exposures that give rise to severe radiation damage. This low sensitivity arises from the small linear energy transfer for fast electrons. Few developable grains are created in the emulsion per electron, while most of the energy of the electrons is wasted in the film base.


Author(s):  
James F. Mancuso ◽  
Leo A. Fama ◽  
William B. Maxwell ◽  
Jerry L. Lehman ◽  
Hasso Weiland ◽  
...  

Micro-diffraction based crystallography is essential to the design and development of many classes of ‘crafted materials’. Although the scanning electron microscope can provide crystallographic information with high spatial resolution, its current utility is severely limited by the low sensitivity of existing diffraction techniques (ref: Dingley). Previously, Joy showed that energy filtering increased contrast and pattern visibility in electron channelling. This present paper discribes the effect of energy filtering on EBSP sensitivity and backscattered SEM imaging.The EBSP detector consisted of an electron energy filter, a microchannel plate detector, a phosphor screen, optical coupler, and a slow scan CCD camera. The electrostatic energy filter used in this experiment was constructed as a cone with 5 coaxial electrodes. The angular field-of-view of the filter was approximately 38°. The microchannel plate, which was the initial sensing component, had high gain and had 50% to 80% detection efficiency for the low energy electrons that passed through the retarding field filter.


1996 ◽  
Vol 5 (1) ◽  
pp. 90-96 ◽  
Author(s):  
Frank E. Musiek ◽  
Cynthia A. McCormick ◽  
Raymond M. Hurley

We performed a retrospective study of 26 patients with acoustic tumors and 26 patients with otologically diagnosed cochlear pathology to determine the sensitivity (hit rate), specificity (false-alarm rate), and efficiency of six auditory brainstem response indices. In addition, a utility value was determined for each of these six indices. The I–V interwave interval, the interaural latency difference, and the absolute latency of wave V provided the highest hit rates, the best A’ values and good utility. The V/I amplitude ratio index provided high specificity but low sensitivity scores. In regard to sensitivity and specificity, using the combination of two indices provided little overall improvement over the best one-index measures.


1989 ◽  
Vol 28 (06) ◽  
pp. 234-242 ◽  
Author(s):  
U. Sechtem ◽  
Sabine Langkamp ◽  
M. Jungehülsing ◽  
H. H. Hilger ◽  
H. Schicha ◽  
...  

Fortyfour patients with recent cardiac catheterization because of recurrent chest pain after coronary artery bypass surgery were studied by magnetic resonance imaging to evaluate graft patency. To assess the efficacy of this non-invasive method 92 coronary artery bypass grafts were examined by the spin-echo technique. ECG-gated transversal sections were acquired between the diaphragm and the aortic arch. The specificity of magnetic resonance imaging was 83% (48/58) for patent grafts. However, the sensitivity in the detection of occluded bypasses was only 56% (19/34). Despite the good specificity, clinical applications of this method are limited because of its low sensitivity.


1974 ◽  
Vol 32 (02/03) ◽  
pp. 483-491
Author(s):  
E. A Loeliger ◽  
M. J Boekhout-Mussert ◽  
L. P van Halem-Visser ◽  
J. D. E Habbema ◽  
H de Jonge

SummaryThe present study concerned the reproducibility of the so-called prothrombin time as assessed with a series of more commonly used modifications of the Quick’s onestage assay procedure, i.e. the British comparative reagent, homemade human brain thromboplastin, Simplastin, Simplastin A, and Thrombotest. All five procedures were tested manually on pooled lyophilized normal and patients’ plasmas. In addition, Simplastin A and Thrombotest were investigated semiautomatically on individual freshly prepared patients’ plasmas. From the results obtained, the following conclusions may be drawn :The reproducibility of results obtained with manual reading on lyophilized plasmas is satisfactory for all five test procedures. For Simplastin, the reproducibility of values in the range of insufficient anticoagulation is relatively low due to the low discrimination power of the test procedure in the near-normal range (so-called low sensitivity of rabbit brain thromboplastins). The reproducibility of Thrombotest excels as a consequence of its particularly easily discerned coagulation endpoint.The reproducibility of Thrombotest, when tested on freshly prepared plasmas using Schnitger’s semiautomatic coagulometer (a fibrinometer-liJce apparatus), is no longer superior to that of Simplastin A.The constant of proportionality between the coagulation times formed with Simplastin A and Thrombotest was estimated at 0.64.Reconstituted Thrombotest is stable for 24 hours when stored at 4° C, whereas reconstituted Simplastin A is not.The Simplastin A method and Thrombotest seem to be equally sensitive to “activation” of blood coagulation upon storage.


1999 ◽  
Vol 19 (04) ◽  
pp. 168-175 ◽  
Author(s):  
M. Weippert-Kretschmer ◽  
V. Kretschmer

SummaryPerioperative bleeding complications due to disorders of primary haemostasis are often underestimated. Routine determination of primary haemostasis is still problematic. The in vivo bleeding time (BT) shows low sensitivity and high variability. In this contribution the results and experiences with the IVBT having been obtained in various studies and during 10 years of routine use are reported. Patients and Methods: Blood donors before and after ASA ingestion, patients with thrombocytopenia as well as congenital and acquired platelet function disorders. Monitoring of desmopressin efficacy. IVBT with Thrombostat 4000 (tests with CaCl2 = TST-CaCl2 and ADP = TST-ADP) and PFA-100 (test cartridges with epinephrine = PFA-EPI and ADP = PFA-ADP). Results and Conclusions: IVBT becomes abnormal with platelet counts <100,000/μl. With platelet counts <50,000/μl the results are mostly outside the methodical range. IVBT proved clearly superior to BT in von Willebrand syndrome (vWS). All 16 patients with vWS were detected by PFA-EPI, whereas with BT 7 of 10 patients with moderate and 1 of 6 patients with mild forms of vWS were spotted. The majority of acquired and congenital platelet function disorders with relevant bleeding tendency were detectable by IVBT. Sometimes diagnostic problems arose in case of storage pool defect. Four to 12 h after ingestion of a single dose of 100 mg ASA the TST-CaCl2 became abnormal in all cases, the PFA-EPI only in 80%. However, the ASA sensitivity of TST-CaCl2 proved even too high when looking for perioperative bleeding complications in an urological study. Therefore, the lower ASS sensitivity of the PFA-100 seems to be rather advantageous for the estimation of a real bleeding risk. The good efficacy of desmopressin in the majority of cases with mild thrombocytopenia, congenital and acquired platelet function disorders and even ASS-induced platelet dysfunction could be proven by means of the IVBT. Thus IVBT may help to increase the reliability of the therapy. However, the IVBT with the PFA-100 is not yet fully developed. Nevertheless, routine use can be recommended when special methodical guidelines are followed.


Sign in / Sign up

Export Citation Format

Share Document