Pressure and Flow Characteristics in a Rotating Two-Pass Square Duct With 45-Deg Angled Ribs

2004 ◽  
Vol 126 (1) ◽  
pp. 212-219 ◽  
Author(s):  
Tong-Miin Liou ◽  
Guang-Yuan Dai

Measurements are presented of the local velocity and wall static-pressure distributions by using laser-Doppler velocimeter and pressure transducers, respectively, in a rotating two-pass square duct with ribs placed on the leading and trailing walls at an angle of 45 deg to the main stream. The ribs were square in cross section and in a parallel mode of arrangement. The rib-height/duct-height ratio and the pitch/rib-height ratio were 0.136 and 10, respectively. The duct Reynolds number was 1×104 and rotation number Ro ranged from 0 to 0.2. Results are addressed in terms of the evolutions of both main flow and cross-stream secondary flow, the distributions of the pressure coefficient, and the variation of friction factor with Ro. In addition, the relationships between the regional averaged Nusselt number, transverse and convective mean velocity component, and turbulent kinetic energy are documented. Simple expressions are obtained to correlate friction factor with Ro, which are lacking in the published literature for ducts ribbed with 45- deg ribs. The 45-deg ribs are found to reduce the friction loss to 60% of the 90-deg ribs for rotating duct under the same operating conditions. For CFD reference, the fully developed flow condition is absent for the rotating ribbed duct investigated. The measured evolution of complex secondary flow vortices is believed to be a challenge to numerical simulations.

Author(s):  
Tong-Miin Liou ◽  
Guang-Yuan Dai

Measurements are presented of the local velocity and wall static-pressure distributions by using laser-Doppler velocimeter and pressure transducers, respectively, in a rotating two-pass square duct with ribs placed on the leading and trailing walls at an angle of 45° to the main stream. The ribs were square in cross-section and in a parallel mode of arrangement. The rib-height/duct-height ratio and the pitch/rib-height ratio were 0.136 and 10, respectively. The duct Reynolds number was 1×104 and rotation number Ro ranged from 0 to 0.2. Results are addressed in terms of the evolutions of both main flow and cross-stream secondary flow and the distributions of the pressure coefficient, which are lacking in the published literature for ducts ribbed with 45° ribs and under rotation. In addition, the relationships between the regional averaged Nusselt number, transverse and convective mean velocity component, and turbulent kinetic energy are documented. The 45° ribs are found to reduce the pressure loss to 60% of the 90° ribs for rotating duct under same operating conditions. For CFD reference, the fully developed flow condition is absent for the rotating ducts investigated. The measured evolution of complex secondary flow vortices is believed to be a challenge to numerical simulations.


2004 ◽  
Vol 128 (2) ◽  
pp. 340-348 ◽  
Author(s):  
Tong-Miin Liou ◽  
Y. Sian Hwang ◽  
Yi-Chen Li

Laser-Doppler velocimetry and pressure measurements are presented of the local velocity and wall pressure distributions in a rotating two-pass square duct with staggered ribs placed on the leading and trailing walls at an angle of 45deg to the main stream. The ribs were square in cross section with the radii of rounds and fillets to rib height ratios of 0.33. The rib-height/duct-height ratio and the pitch/rib-height ratio were 0.136 and 10, respectively. The duct Reynolds number was 1×104 and rotation number Ro ranged from 0 to 0.2. Results are documented in terms of the evolutions of both main flow and cross-stream secondary flow, the distributions of the pressure coefficient, and the variation of friction factor with Ro. For CFD reference, the periodic fully developed flow condition is absent for the present length of the rotating passage roughened with staggered 45deg ribs. In addition, the relationships between the regional averaged Nusselt number, transverse and convective mean velocity component, and turbulent kinetic energy are addressed. Using these relationships the general superiority of heat transfer enhancement of the staggered 45deg ribs arrangement over the in-line one can be reasonably illustrated. Simple expressions are obtained to correlate the friction factor with Ro, which are lacking in the published literature for passages ribbed with staggered 45deg ribs. The staggered 45deg ribs are found to reduce the friction loss to about 88%±1% of the in-line 45deg ribs for the rotating passage under the same operating conditions. The respective contributions of the angled ribs and passage rotation on the passage friction loss are identified.


Author(s):  
Tong-Miin Liou ◽  
Yi-Sian Hwang ◽  
Yi-Chen Li

Laser-Doppler velocimetry and pressure measurements are presented of the local velocity and wall pressure distributions in a rotating two-pass square duct with staggered ribs placed on the leading and trailing walls at an angle of 45° to the main stream. The ribs were square in cross-section with the radii of rounds and fillets to rib height ratios of 0.33. The rib-height/duct-height ratio and the pitch/rib-height ratio were 0.136 and 10, respectively. The duct Reynolds number was 1×104 and rotation number Ro ranged from 0 to 0.2. Results are documented in terms of the evolutions of both main flow and cross-stream secondary flow, the distributions of the pressure coefficient, and the variation of friction factor with Ro. For CFD reference, the periodic fully developed flow condition is absent for the present length of the rotating passage roughened with staggered 45° ribs. In addition, the relationships between the regional averaged Nusselt number, transverse and convective mean velocity component, and turbulent kinetic energy are addressed. Using these relationships the general superiority of heat transfer enhancement of the staggered 45° ribs arrangement over the in-line one can be reasonably illustrated. Simple expressions are obtained to correlate the friction factor with Ro, which are lacking in the published literature for passages ribbed with staggered 45° ribs. The staggered 45° ribs are found to reduce the friction loss to about 88%±1% of the in-line 45° ribs for the rotating passage under the same operating conditions. The respective contributions of the angled ribs and passage rotation on the passage friction loss are identified.


2003 ◽  
Vol 125 (3) ◽  
pp. 565-574 ◽  
Author(s):  
Tong-Miin Liou ◽  
Meng-Yu Chen ◽  
Yu-Ming Wang

Transient thermochromic liquid crystal thermography, a laser-Doppler velocimeter, and pressure transducers have been used to measure the local heat transfer, velocity, and wall static-pressure distributions, respectively, in a rotating two-pass square duct with 90-deg ribs detached from the leading and trailing walls. The ribs were square in cross-section and their detached-distance/height ratio was 0.38. The rib-height/duct-height ratio and the pitch/rib-height ratio were 0.136 and 10, respectively. The duct Reynolds number was 1×104 and rotation number ranged from 0 to 0.2. Results are compared with attached rib cases in terms of regional averaged Nusselt number, transverse mean velocity component, pressure coefficient distributions and variation of friction factor with rotation number. The competition between convection effect of the wall jet and downwash effect of the rib-top separated shear layer on the heat transfer augmentation is addressed in detail. Discussion on local Nusselt number distribution, mean velocity components, and turbulent kinetic energy is included. Simple expressions are obtained to correlate friction factor with rotation number. Rib detachment is found to enhance heat transfer on the leading wall of the first outward pass and on the trailing wall of the second inward pass over as compared to the attached rib case. The trend is reversed on the other two walls. Nevertheless, detached ribs create more uniform heat transfer distributions on the leading and trailing walls than attached ribs.


Author(s):  
Tong-Miin Liou ◽  
Meng-Yu Chen ◽  
Yu-Ming Wang

Transient thermochromic liquid crystal thermography, a laser-Doppler velocimeter, and pressure transducers have been used to measure the local heat transfer, velocity, and wall static-pressure distributions, respectively, in a rotating two-pass square duct with 90° ribs detached from the leading and trailing walls. The ribs were square in cross-section and their detached-distance/height ratio was 0.38. The rib-height/duct-height ratio and the pitch/rib-height ratio were 0.136 and 10, respectively. The duct Reynolds number was 1×104 and rotation number ranged from 0 to 0.2. Results are compared with attached rib cases in terms of regional averaged Nusselt number, transverse mean velocity component, pressure coefficient distributions and variation of friction factor with rotation number. The competition between convection effect of the wall jet and downwash effect of the rib-top separated shear layer on the heat transfer augmentation is addressed in detail. Discussion on local Nusselt number distribution, mean velocity components, and turbulent kinetic energy is included. Simple expressions are obtained to correlate friction factor with rotation number. Rib detachment is found to enhance heat transfer on the leading wall of the first outward pass and on the trailing wall of the second inward pass over as compared to the attached rib case. The trend is reversed on the other two walls. Nevertheless, detached ribs create more uniform heat transfer distributions on the leading and trailing walls than attached ribs.


Author(s):  
Tong-Miin Liou ◽  
Yu-Sian Hwang ◽  
Meng-Yu Chen

Measurements of flow field, heat transfer coefficient, and wall static pressure distribution were made in a rotating two-pass square duct with detachment of 90° ribs from the first-pass leading wall and second-pass trailing wall as well as attachment of 90° ribs onto the other two opposite walls. Laser-Doppler velocimetry was used to measure the local flow velocity. The ribs were square in cross-section and their detached-distance/height ratio was 0.38. The rib-height/duct-height ratio and the pitch/rib-height ratio were 0.136 and 10, respectively. Duct Reynolds number was fixed at 1×104 and rotating number ranged from 0 to 0.2. Results are documented in terms of the main flow development, cross-stream secondary flow structure, the distributions of the pressure coefficient, the variation of friction factor with Ro, and passage averaged Nusselt number ratios under a constant flow rate and a constant pumping power condition. For CFD reference, the periodic fully developed rotating flow condition is attained after the 6th rib pair in the first pass. In addition, the relationships between the regional averaged Nusselt number, transverse and convective mean velocity component, and turbulent kinetic energy are addressed. Using these relationships the general superiority of heat transfer enhancement of the attached-detached 90° ribs arrangement over the attached-attached one and detached-detached one can be reasonably illustrated. Simple expressions are obtained to correlate the friction factor with Ro, which are lacking in the published literature. The respective contributions of the ribs and passage rotation on the passage friction loss are identified.


Author(s):  
J. Kulman ◽  
D. Gray ◽  
S. Sivanagere ◽  
S. Guffey

Heat transfer and flow characteristics have been determined for a single-phase rectangular loop thermosiphon. The plane of the loop was vertical, and tests were performed with in-plane tilt angles ranging from 3.6° CW to 4.2° CCW. Velocity profiles were measured in one vertical leg of the loop using both a single-component Laser Doppler Velocimeter (LDV), and a commercial Particle Image Velocimeter (PIV) system. The LDV data and PIV data were found to be in good agreement. The measured average velocities were approximately 2–2.5 cm/s at an average heating rate of 70 W, and were independent of tilt angle. Significant RMS fluctuations of 10–20% of the mean velocity were observed in the test section, in spite of the laminar or transitional Reynolds numbers (order of 700, based on the hydraulic diameter). These fluctuations have been attributed to vortex shedding from the upstream temperature probes and mitre bends, rather than to fully developed turbulence. Animations of the PIV data clearly show these large scale unsteady flow patterns. Multiple steady state flow patterns were not observed.


1993 ◽  
Vol 115 (2) ◽  
pp. 292-301 ◽  
Author(s):  
Wen-Hwa Chen ◽  
Ray Jan

The continuity equation and Navier-Stokes equations derived from a non-orthogonal helical coordinate system are solved by the Galerkin finite-element method in an attempt to study the torsion effect on the fully developed laminar flow in the helical square duct. Since high-order terms of curvature and torsion are considered, the approach is also applicable to the problems with finite curvature and torsion. The interaction effects of curvature, torsion, and the inclined angle of the cross section on the secondary flow, axial velocity, and friction factor in the helical square duct are presented. The results show that the torsion has more pronounced effect on the secondary flow rather than the axial flow. In addition, unlike the flow in the toroidal square duct, Dean’s instability of the secondary flow, which occurs near the outer wall in the helical square duct, can be avoided due to the effects of torsion and/or inclined angle. In such cases, a decrease of the friction factor is observed. However, as the pressure gradient decreases to a small value, the friction factor for the toroidal square duct is also applicable to the helical square duct.


1993 ◽  
Vol 115 (1) ◽  
pp. 109-114 ◽  
Author(s):  
T.-M. Liou ◽  
Y.-Y. Wu ◽  
Y. Chang

Laser-Doppler velocimeter measurements of mean velocities, turbulence intensities, and Reynolds stresses are presented for periodic fully developed flows in a channel with square rib-disturbed walls on two opposite sides. Quantities such as the vorticity thickness and turbulent kinetic energy are used to characterize the flow. The investigated flow was periodic in space. The Reynolds number based on the channel hydraulic diameter was 3.3×104. The ratios of pitch to rib-height and rib-height to chamber-height were 10 and 0.133, respectively. Regions where maximum and minimum Reynolds stress and turbulent kinetic energy occurred were identified from the results. The growth rate of the shear layers of the present study was compared with that of a backward-facing step. The measured turbulence anisotropy and structure parameter distribution were used to examine the basic assumptions embedded in the k–ε and k–ε–A models. For a given axial station, the peak axial mean-velocity was found not to occur at the center point. The secondary flow was determined to be Prandtl’s secondary flow of the second kind according to the measured streamwise mean vorticity and its production term.


2019 ◽  
Vol 29 (4) ◽  
pp. 1432-1447 ◽  
Author(s):  
Gülbanu Şenay ◽  
Metin Kaya ◽  
Engin Gedik ◽  
Muhammet Kayfeci

Purpose The purpose of this study is to numerically investigate the heat transfer enhancement by using two different nanofluids flow throughout the square duct under a constant heat flux (500 × 103 W/m2). Design/methodology/approach In numerical computations, ANSYS Fluent code based on the finite volume method was used to solve governing equations by iteratively. Water, Al2O3-water and TiO2-water nanofluids were used for different flow velocities changing 1 m/s to 8 m/s (i.e. Reynolds number varying from 3,000 to 100,000). Findings The results were compared with results published previously in the literature and close agreement was observed especially considering Dittus and Boelter correlation for water. It was found that from the obtained results, increasing flow velocity and volume fractions of nanoparticles has caused to increase Nu number for all cases. Besides, variations of pressure drop, Darcy friction factor are presented graphically and discussed in detail. The results are consistent with a deviation of 1.3 to 15 per cent with the results of other researchers. Originality/value The effects of the Re numbers and volume fractions of nanoparticles (0.01 ≤ Φ ≤ 0.04) on the heat transfer and fluid flow characteristics such as average Nu number, pressure drop (ΔP) and Darcy friction factor (f) were investigated.