Design Study of Part-Flow Evaporative Gas Turbine Cycles: Performance and Equipment Sizing—Part II: Industrial Core

2002 ◽  
Vol 125 (1) ◽  
pp. 216-227 ◽  
Author(s):  
N. D. A˚gren ◽  
M. O. J. Westermark

This is Part II of a two-part paper and presents calculation results of a part-flow EvGT cycle based on gas turbine data for the ABB GTX100 (modified for intercooling). The evaporative gas turbine cycle is a new high-efficiency cycle that has reached the pilot testing stage. This paper presents calculation results of a new humidification strategy based on part-flow humidification. This strategy involves using only a fraction of the compressed air for humidification. Thermodynamically, it can be shown that not all the air needs to be passed through the humidification system to attain the intrinsic good flue gas heat recovery of an EvGT cycle. The presented system also includes live steam production and superheating, by heat from the hottest flue gas region, for injection. The humidifier then only uses the lower temperature levels, where it is best suited. The analyzed system is based on data for the ABB GTX100.gas turbine in intercooled mode. Part I of this two-part paper presents the results based on data for the aeroderovative Rolls Royce Trent. Simulation results include electric efficiency and other process data as function of degree of part flow. A detailed model of the humidifier is used, which produces sizing results both for column height and diameter. Paper I includes detailed description of the modeling. For the GTX100 system, full-flow humidification generates an electric efficiency of 52.6% (simple cycle 36.2%). The efficiency is virtually unaffected if the air portion to humidification is cut to 60% of accessible compressor air (represents 48% of compressor intake). If 30% of air from the compressor after cooling bleed (24% of intake) is led to the humidifier, the efficiency is reduced to 52.2%. On the other hand is the total heat exchanger area reduced by 20% and column volume by 50%. This calls for a recommendation not to use all the compressed air for humidification. It is recommended to use 15–30% of compressor intake air. The exact economic optimum depends on local fuel prices, CO2 taxes, interest rates, etc.

Author(s):  
Niklas D. Ågren ◽  
Mats O. J. Westermark

This is part two of a 2-part paper and presents calculation results of a part flow EvGT cycle based on gas turbine data for the ABB GTX100 (modified for intercooling). The evaporative gas turbine cycle is a new high efficiency cycle that has reached the pilot testing stage. This paper presents calculation results of a new humidification strategy based on part flow humidification. This strategy involves using only a fraction of the compressed air for humidification. Thermodynamically, it can be shown that not all the air needs to be passed through the humidification system to attain the intrinsic good flue gas heat recovery of an EvGT cycle. The presented system also includes live steam production and superheating, by heat from the hottest flue gas region, for injection. The humidifier then only uses the lower temperature levels, where it is best suited. The analyzed system is based on data for the ABB GTX100.gas turbine in intercooled mode. Part 1 of this 2-part paper presents the results based on data for the aeroderovative Rolls Royce Trent. Simulation results include electric efficiency and other process data as function of degree of part flow. A detailed model of the humidifier is used, which produces sizing results both for column height and diameter. Paper 1 includes detailed description of the modelling. For the GTX100-system, full flow humidification generates an electric efficiency of 52.6% (simple cycle 36.2%). The efficiency is virtually unaffected if the air portion to humidification is cut to 60% of accessible compressor air (represents 48% of compressor intake). If 30% of air from the compressor after cooling bleed (24% of intake)is led to the humidifier, the efficiency is reduced to 52.2%. On the other hand is the total heat exchanger area reduced by 20% and column volume by 50%. This calls for a recommendation not to use all the compressed air for humidification. It is recommended to use 15-30% of compressor intake air. The exact economic optimum depends on local fuel prices, CO2-taxes, interest rates et c.


Author(s):  
Niklas D. Ågren ◽  
Mats O. J. Westermark

The evaporative gas turbine cycle is a new high efficiency power cycle that has reached the pilot testing stage. This paper presents calculation results of a new humidification strategy based on part flow humidification. This strategy involves using only a fraction of the compressed air for humidification. Thermodynamically, it can be shown that not all the air needs to be passed through the humidification system to attain the intrinsic good flue gas heat recovery of an EvGT cycle. The system presented also includes live steam production and superheating by heat from the hottest flue gas region. The humidifier only uses the lower temperature levels flue gas heat, where it is best suited. The analyzed system is based on data for the aeroderivative Rolls Royce Trent as a gas turbine core. Part 2 of this 2-part paper presents the results based on data for the industrial gas turbine ABB GTX100. Simulation results include electric efficiency and other process datas as functions of degree of part flow. A detailed model of the humidifier is also used and described, which produces sizing results both for column height and diameter. Full flow humidification generates an electric efficiency of 51.5% (simple cycle 41%). The efficiency increases when the humidification air flow is reduced, to reach a maximum of 52.9% when air flow to the humidification amounts to around 12% of the intake air to the compressor. At the same time, total heat exchanger area is reduced by 50% and humidifier volume by 36% compared to full flow humidification. This calls for a recommendation not to use all the compressed air for humidification.


2002 ◽  
Vol 125 (1) ◽  
pp. 201-215 ◽  
Author(s):  
N. D. A˚gren ◽  
M. O. J. Westermark

The evaporative gas turbine cycle is a new high-efficiency power cycle that has reached the pilot testing stage. This paper presents calculation results of a new humidification strategy based on part flow humidification. This strategy involves using only a fraction of the compressed air for humidification. Thermodynamically, it can be shown that not all the air needs to be passed through the humidification system to attain the intrinsic good flue gas heat recovery of an EvGT cycle. The system presented also includes live steam production and superheating by heat from the hottest flue gas region. The humidifier only uses the lower temperature levels flue gas heat, where it is best suited. The analyzed system is based on data for the aeroderivative Rolls Royce Trent as a gas turbine core. Part II of this two-part paper presents the results based on data for the industrial gas turbine ABB GTX100. Simulation results include electric efficiency and other process datas as functions of degree of part flow. A detailed model of the humidifier is also used and described, which produces sizing results both for column height and diameter. Full flow humidification generates an electric efficiency of 51.5% (simple cycle 41%). The efficiency increases when the humidification air flow is reduced, to reach a maximum of 52.9% when air flow to the humidification amounts to around 12% of the intake air to the compressor. At the same time, total heat exchanger area is reduced by 50% and humidifier volume by 36% compared to full flow humidification. This calls for a recommendation not to use all the compressed air for humidification.


Author(s):  
Niklas D. Ågren ◽  
Mats O. Westermark ◽  
Michael A. Bartlett ◽  
Torbjörn Lindquist

The evaporative gas turbine (EvGT), also known as the humid air turbine (HAT) cycle, is a novel advanced gas turbine cycle that has attracted considerable interest for the last decade. This high efficiency cycle shows the potential to be competitive with Diesel engines or combined cycles in small and intermediate scale plants for power production — and/or cogeneration. A 0.6 MW natural gas fired EvGT pilot plant has been constructed by a Swedish national research group in cooperation between universities and industry. The plant is located at the Lund Institute of Technology, Lund, Sweden. The pilot plant uses a humidification tower with metallic packing in which heated water from the flue gas economizer is brought into direct counter current contact with the pressurized air from the compressor. This gives an efficient heat recovery and thereby a thermodynamically sound cycle. As the hot sections in high temperature gas turbines are sensitive to particles and alkali compounds, water quality issues need to be carefully considered. As such, apart from evaluating the thermodynamic and part load performance characteristics of the plant, and verifying the operation of the high pressure humidifier, much attention is focused on the water chemistry issues associated with the recovery and reuse of condensate water from the flue gas. A water treatment system has been designed and integrated into the pilot plant. This paper presents the first water quality results from the plant. The experimental results show that the condensate contains low levels of alkali and calcium, around 2 mg/l Σ(K,Na,Ca), probably originating from the unfiltered compressor intake. About 14 mg/l NO2− + NO3− comes from condensate absorption of flue gas NOx. Some Cu is noted, 16 mg/l, which originates from copper corrosion of the condenser tubes. After CO2-stripping, condensate filtration and a mixed bed ion exchanger, the condensate is of suitable quality for reuse as humidification water. The need for large quantities of demineralized water has by many authors been identified as a drawback for the evaporative cycle. However, by cooling the humid flue gas, the recovery of condensed water cuts the need of water feed. A self supporting water circuit can be achieved, with no need for any net addition of water to the system. In the pilot plant, this was achieved by cooling the flue gas to around 35°C.


2013 ◽  
Vol 275-277 ◽  
pp. 2477-2480
Author(s):  
Hui Cao ◽  
Yan Liu ◽  
Chang Ji Lin

The flue gas turbine discussed in this article have relatively backward pneumatic design, low operating efficiency, as well as problems of vibration, catalyst accumulation and fouling etc. It cannot realize better generating power effect because of short running cycle, high failure rate, and low recovery of heat and pressure energy generated of high temperature flue gas. To solve the above problems, this article proposes failure analysis. Flue gas turbine problems appear for the main reasons: the steam of the regeneration standpipe reach the regenerator, lead to catalyst breaking and give rise to a large number of catalyst fines, which causes the third cyclone separator blocked and the flue gas turbine fouled. Then, repair the leakage point of regeneration standpipe, maintain smooth operation,and transform leaf type of flue gas turbine. The flue gas turbine restored power generation status after overhaul. achieve the purpose of high efficiency and long-term stable operation.


Author(s):  
Mortaza Yari

The evaporative gas turbine cycle is a new high-efficiency power cycle that has reached the pilot plant testing stage. The latest configuration proposed for this cycle is known as part flow evaporative gas turbine cycle (PEvGT) in which humidification is combined with steam injection. Having advantages of both steam injected and humid air cycles, it is regarded as a very desirable plant for future. The aim of this work is to investigate the economic performance of the PEvGT cycles: PEvGT and PEvGT-IC (Intercooled PEvGT cycle), based on the thermoeconomic analysis. The results are presented and the influence of the several parameters is discussed: pressure ratio, part-flow humidification rate and the cycle configuration. Also the thermoeconomic optimization of the cycles have been done and discussed.


Author(s):  
Mortaza Yari ◽  
Kazem Sarabchi

The evaporative gas turbine cycle is a new high-efficiency power cycle that has reached the pilot plant testing stage. The latest configuration proposed for this cycle is known as part flow evaporative gas turbine cycle (PEvGT) in which humidification is combined with steam injection. Having advantages of both steam injected and humid air cycles, it is regarded as a very desirable plant for future. A mathematical model of the PEvGT cycle was presented in the previous work (Yari and Sarabchi, 2004), in order to do the analysis of the cycles. In this work the exergy equations have been added to the mathematical model. The aim of this work is to investigate the performance of the PEvGT cycles: PEvGT and PEvGT-IC (Intercooled PEvGT cycle), based on the exergy analysis. The results are presented and the influence of the several parameters is discussed: pressure ratio, part-flow humidification rate and the cycle configuration. Also the optimum cycle configuration has been selected from the exergetic point of view.


2000 ◽  
Vol 124 (1) ◽  
pp. 96-102 ◽  
Author(s):  
N. D. A˚gren ◽  
M. O. Westermark ◽  
M. A. Bartlett ◽  
T. Lindquist

The evaporative gas turbine (EvGT), also known as the humid air turbine (HAT) cycle, is a novel advanced gas turbine cycle that has attracted considerable interest for the last decade. This high-efficiency cycle shows the potential to be competitive with Diesel engines or combined cycles in small and intermediate scale plants for power production and/or cogeneration. A 0.6 MW natural gas-fired EvGT pilot plant has been constructed by a Swedish national research group in cooperation between universities and industry. The plant is located at the Lund Institute of Technology, Lund, Sweden. The pilot plant uses a humidification tower with metallic packing in which heated water from the flue gas economizer is brought into direct counter current contact with the pressurized air from the compressor. This gives an efficient heat recovery and thereby a thermodynamically sound cycle. As the hot sections in high-temperature gas turbines are sensitive to particles and alkali compounds, water quality issues need to be carefully considered. As such, apart from evaluating the thermodynamic and part-load performance characteristics of the plant, and verifying the operation of the high-pressure humidifier, much attention is focused on the water chemistry issues associated with the recovery and reuse of condensate water from the flue gas. A water treatment system has been designed and integrated into the pilot plant. This paper presents the first water quality results from the plant. The experimental results show that the condensate contains low levels of alkali and calcium, around 2 mg/l Σ(K,Na,Ca), probably originating from the unfiltered compressor intake. About 14 mg/l NO2−+NO3− comes from condensate absorption of flue gas NOx. Some Cu is noted, 16 mg/l, which originates from copper corrosion of the condenser tubes. After CO2 stripping, condensate filtration and a mixed bed ion exchanger, the condensate is of suitable quality for reuse as humidification water. The need for large quantities of demineralized water has by many authors been identified as a drawback for the evaporative cycle. However, by cooling the humid flue gas, the recovery of condensed water cuts the need of water feed. A self-supporting water circuit can be achieved, with no need for any net addition of water to the system. In the pilot plant, this was achieved by cooling the flue gas to around 35°C.


Author(s):  
M Yari ◽  
K Sarabchi

The evaporative gas turbine cycle is a new high-efficiency power cycle that has reached the pilot plant testing stage. This article presents the construction of a mathematical model for thermodynamic simulation of part-flow evaporative gas turbine cycle including steam injection. The maximum deviation of predicted performance results by this model from available data in literature was 1 per cent. Then, changes in configuration of this cycle have been investigated. Configuration changes concern using feed water heater and injection of saturated vapour instead of superheated vapour to the humid air in the cycle. This investigation shows that both these strategies were in the direction of improvement of efficiency and specific work of cycles (intercooled and non-intercooled). The results obtained from this research show that using spray cooler as the intercooler in the intercooled cycle offers interesting perspectives. In addition, the optimization of part-flow evaporative gas turbine (PEvGT) cycles in the systematic manner is presented and discussed.


Sign in / Sign up

Export Citation Format

Share Document