Thermoeconomic Considerations in the Optimum Allocation of Heat Transfer Inventory for Refrigeration and Heat Pump Systems

2002 ◽  
Vol 124 (1) ◽  
pp. 28-33 ◽  
Author(s):  
Mohamed A. Antar ◽  
Syed M. Zubair

Thermoeconomics is defined as attaching monetary values to heat exchanger conductances of a given plant. In this study, optimum allocation of heat transfer inventory for heat exchangers in a refrigeration system with specified power input or cooling capacity, and for a heat pump with specified heating capacity is investigated. The ratio of hot- to cold-end conductance unit cost ratio, G, was considered in the analysis as an additional parameter of considerable importance to the designer. A closed-form expression is given in terms of unit cost of conductances of both the heat exchangers. The results show a strong dependence of the total cost on the absolute temperature ratios as well as the hot- to the cold-end conductance cost ratio. It is demonstrated in the illustrative example that for G=0.1, the conductance of the hot-end heat exchanger is about three times the cold-end heat exchanger.

Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1762 ◽  
Author(s):  
Zhe Wang ◽  
Fenghui Han ◽  
Yulong Ji ◽  
Wenhua Li

A marine seawater source heat pump is based on the relatively stable temperature of seawater, and uses it as the system’s cold and heat source to provide the ship with the necessary cold and heat energy. This technology is one of the important solutions to reduce ship energy consumption. Therefore, in this paper, the heat exchanger in the CO2 heat pump system with graphene nano-fluid refrigerant is experimentally studied, and the influence of related factors on its heat transfer enhancement performance is analyzed. First, the paper describes the transformation of the heat pump system experimental bench, the preparation of six different mass concentrations (0~1 wt.%) of graphene nanofluid and its thermophysical properties. Secondly, this paper defines graphene nanofluids as beneficiary fluids, the heat exchanger gains cold fluid heat exergy increase, and the consumption of hot fluid heat is heat exergy decrease. Based on the heat transfer efficiency and exergy efficiency of the heat exchanger, an exergy transfer model was established for a seawater source of tube heat exchanger. Finally, the article carried out a test of enhanced heat transfer of heat exchangers with different concentrations of graphene nanofluid refrigerants under simulated seawater constant temperature conditions and analyzed the test results using energy and an exergy transfer model. The results show that the enhanced heat transfer effect brought by the low concentration (0~0.1 wt.%) of graphene nanofluid is greater than the effect of its viscosity on the performance and has a good exergy transfer effectiveness. When the concentration of graphene nanofluid is too high, the resistance caused by the increase in viscosity will exceed the enhanced heat transfer gain brought by the nanofluid, which results in a significant decrease in the exergy transfer effectiveness.


2013 ◽  
Vol 700 ◽  
pp. 231-234
Author(s):  
Lian Yang ◽  
Yong Hong Huang ◽  
Liu Zhang

There are many ground source heat pumps in engineering construction application. However, Research on heat exchanger models of single-hole buried vertical ground source heat pump mostly focuses on single U-tube ground heat exchangers other than double U-tube ones in China currently. Compared with single U-tubes, double U-tubes have the heat transfer particularity of asymmetry. Therefore, the use of the traditional single tube models would have large error in the simulation of the actual double U-tube heat exchangers. This paper frames a three-dimensional heat transfer model for the vertical single-hole buried double u-tube heat exchanger in a ground source heat pump system. The model considers the performance of U-bube material and uses a dual coordinate system and makes the control elemental volumes superimposed.


1987 ◽  
Vol 109 (2) ◽  
pp. 287-294 ◽  
Author(s):  
S. M. Zubair ◽  
P. V. Kadaba ◽  
R. B. Evans

This paper presents a closed-form analytical method for the second-law-based thermoeconomic optimization of two-phase heat exchangers used as condensers or evaporators. The concept of “internal economy” as a means of estimating the economic value of entropy generated (due to finite temperature difference heat transfer and pressure drops) has been proposed, thus permitting the engineer to trade the cost of entropy generation in the heat exchanger against its capital expenditure. Results are presented in terms of the optimum heat exchanger area as a function of the exit/inlet temperature ratio of the coolant, unit cost of energy dissipated, and the optimum overall heat transfer coefficient. The total heat transfer resistance represented by (1/U = C1 + C2 Re−n) in the present analysis is patterned after Wilson (1915) which accommodates the complexities associated with the determination of the two-phase heat transfer coefficient and the buildup of surface scaling resistances. The analysis of a water-cooled condenser and an air-cooled evaporator is presented with supporting numerical examples which are based on the thermoeconomic optimization procedure of this paper.


Author(s):  
Douglas B. Heymann ◽  
Deborah V. Pence

A one-dimensional model for single-phase flow in a fractal-like branching microchannel heat exchanger was developed to estimate bulk fluid temperature and pressure distributions in co-flow and counter-flow configurations. The model assumes incompressible flow with thermally and hydrodynamically developing boundary layers. An existing correlation for the heat transfer coefficient in the simultaneously developing boundary layer region was found to adequately describe results from a three-dimensional computational analysis of conjugate heat transfer and fluid flow using the commercial software package Star-CCM+. Additionally, the fin efficiency was found to be an important descriptor of the difference in performance between a heat exchanger made of low and high thermal conductivity material. A parametric study was performed with the one-dimensional model to assess the influence of flow conditions and flow network characteristics on performance measures, including the benefit-to-cost ratio, which is defined as the heat transfer divided by flow power. Results of heat transfer versus log-mean temperature difference and effectiveness versus number of transfer units are compared between branching and straight microchannel heat exchangers.


2013 ◽  
Vol 38 (4) ◽  
pp. 565-570 ◽  
Author(s):  
Bartłomiej Kruk

Abstract Research in termoacoustics began with the observation of the heat transfer between gas and solids. Using this interaction the intense sound wave could be applied to create engines and heat pumps. The most important part of thermoacoustic devices is a regenerator, where press of conversion of sound energy into thermal or vice versa takes place. In a heat pump the acoustic wave produces the temperature difference at the two ends of the regenerator. The aim of the paper is to find the influence of the material used for the construction of a regenerator on the properties of a thermoacoustic heat pump. Modern technologies allow us to create new materials with physical properties necessary to increase the temperature gradient on the heat exchangers. The aim of this paper is to create a regenerator which strongly improves the efficiency of the heat pump.


Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1853 ◽  
Author(s):  
Pavel Neuberger ◽  
Radomír Adamovský

The efficiency of a heat pump energy system is significantly influenced by its low-temperature heat source. This paper presents the results of operational monitoring, analysis and comparison of heat transfer fluid temperatures, outputs and extracted energies at the most widely used low temperature heat sources within 218 days of a heating period. The monitoring involved horizontal ground heat exchangers (HGHEs) of linear and Slinky type, vertical ground heat exchangers (VGHEs) with single and double U-tube exchanger as well as the ambient air. The results of the verification indicated that it was not possible to specify clearly the most advantageous low-temperature heat source that meets the requirements of the efficiency of the heat pump operation. The highest average heat transfer fluid temperatures were achieved at linear HGHE (8.13 ± 4.50 °C) and double U-tube VGHE (8.13 ± 3.12 °C). The highest average specific heat output 59.97 ± 41.80 W/m2 and specific energy extracted from the ground mass 2723.40 ± 1785.58 kJ/m2·day were recorded at single U-tube VGHE. The lowest thermal resistance value of 0.07 K·m2/W, specifying the efficiency of the heat transfer process between the ground mass and the heat transfer fluid, was monitored at linear HGHE. The use of ambient air as a low-temperature heat pump source was considered to be the least advantageous in terms of its temperature parameters.


Author(s):  
H. Zabiri ◽  
V. R. Radhakrishnan ◽  
M. Ramasamy ◽  
N. M. Ramli ◽  
V. Do Thanh ◽  
...  

The Crude Preheat Train (CPT) is a set of large heat exchangers which recover the waste heat from product streams back to preheat the crude oil. The overall heat transfer coefficient in these heat exchangers may be significantly reduced due to fouling. One of the major impacts of fouling in CPT operation is the reduced heat transfer efficiency. The objective of this paper is to develop a predictive model using statistical methods which can a priori predict the rate of the fouling and the decrease in heat transfer efficiency in a heat exchanger in a crude preheat train. This predictive model will then be integrated into a preventive maintenance diagnostic tool to plan the cleaning of the heat exchanger to remove the fouling and bring back the heat exchanger efficiency to their peak values. The fouling model was developed using historical plant operating data and is based on Neural Network. Results show that the predictive model is able to predict the shell and tube outlet temperatures with excellent accuracy, where the Root Mean Square Error (RMSE) obtained is less than 1%, correlation coefficient R2 of approximately 0.98 and Correct Directional Change (CDC) values of more than 90%. A preliminary case study shows promising indication that the predictive model may be integrated into a preventive maintenance scheduling for the heat exchanger cleaning.


2013 ◽  
Vol 832 ◽  
pp. 160-165 ◽  
Author(s):  
Mohammad Alam Khairul ◽  
Rahman Saidur ◽  
Altab Hossain ◽  
Mohammad Abdul Alim ◽  
Islam Mohammed Mahbubul

Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide excellent thermal performance of this type of heat exchangers. In the present study, the effect of different nanofluids on the heat transfer performance in a helically coiled heat exchanger is examined. Four different types of nanofluids CuO/water, Al2O3/water, SiO2/water, and ZnO/water with volume fractions 1 vol.% to 4 vol.% was used throughout this analysis and volume flow rate was remained constant at 3 LPM. Results show that the heat transfer coefficient is high for higher particle volume concentration of CuO/water, Al2O3/water and ZnO/water nanofluids, while the values of the friction factor and pressure drop significantly increase with the increase of nanoparticle volume concentration. On the contrary, low heat transfer coefficient was found in higher concentration of SiO2/water nanofluids. The highest enhancement of heat transfer coefficient and lowest friction factor occurred for CuO/water nanofluids among the four nanofluids. However, highest friction factor and lowest heat transfer coefficient were found for SiO2/water nanofluids. The results reveal that, CuO/water nanofluids indicate significant heat transfer performance for helically coiled heat exchanger systems though this nanofluids exhibits higher pressure drop.


2021 ◽  
Vol 9 (1) ◽  
pp. 60-71
Author(s):  
Abeth Novria Sonjaya ◽  
Marhaenanto Marhaenanto ◽  
Mokhamad Eka Faiq ◽  
La Ode M Firman

The processed wood industry urgently needs a dryer to improve the quality of its production. One of the important components in a dryer is a heat exchanger. To support a durable heat transfer process, a superior material is needed. The aim of the study was to analyze the effectiveness of the application of cross-flow flat plate heat exchangers to be used in wood dryers and compare the materials used and simulate heat transfer on cross-flow flat plate heat exchangers using Computational Fluid Dynamic simulations. The results showed that there was a variation in the temperature out of dry air and gas on the flat plate heat exchanger and copper material had a better heat delivery by reaching the temperature out of dry air and gas on the flat plate type heat exchanger of successive cross flow and.   overall heat transfer coefficient value and the effectiveness value of the heat exchanger of the heat transfer characteristics that occur with the cross-flow flat plate type heat exchanger in copper material of 251.74725 W/K and 0.25.


Sign in / Sign up

Export Citation Format

Share Document