A Cable Extension Transducer Based Two-Dimensional Position Sensor for Industrial Applications

2000 ◽  
Vol 124 (1) ◽  
pp. 105-108 ◽  
Author(s):  
Daehie Hong ◽  
Keith J. Mueller ◽  
Steven A. Velinsky

A technique for two-dimensional position measurement is presented through the use of cable-extension transducers. The method includes the use of two such transducers and the planar position is determined through triangulation. This paper also presents a design methodology for the sensor system which is developed based on uncertainty analysis results. The performance of the sensor system is verified through experiments with coordinate measurement machines. This new type of position sensor can be easily used in a wide variety of automation applications in industry for two-dimensional position measurements with high accuracy over a relatively large range, and it is both cost effective and robust against hostile environments.

Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1301
Author(s):  
Federico Cavedo ◽  
Parisa Esmaili ◽  
Michele Norgia

A low-cost optical reflectivity sensor is proposed in this paper, able to detect the presence of objects or surface optical properties variations, at a distance of up to 20 m. A collimated laser beam is pulsed at 10 kHz, and a synchronous digital detector coherently measures the back-diffused light collected through a 1-inch biconvex lens. The sensor is a cost-effective solution for punctual measurement of the surface reflection at different distances. To enhance the interference immunity, an algorithm based on a double-side digital baseline restorer is proposed and implemented to accurately detect the amplitude of the reflected light. As results show, the sensor is robust against ambient light and shows a strong sensitivity on a wide reflection range. The capability of the proposed sensor was evaluated experimentally for object detection and recognition, in addition to dedicated measurement systems, like remote encoders or keyphasors, realized far from the object to be measured.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shahrbanoo Hamedi ◽  
M. Mehdi Afsahi ◽  
Ali Riahi-Madvar ◽  
Ali Mohebbi

AbstractThe main advantages of the dried enzymes are the lower cost of storage and longer time of preservation for industrial applications. In this study, the spouted bed dryer was utilized for drying the garden radish (Raphanus sativus L.) root extract as a cost-effective source of the peroxidase enzyme. The response surface methodology (RSM) was used to evaluate the individual and interactive effects of main parameters (the inlet air temperature (T) and the ratio of air flow rate to the minimum spouting air flow rate (Q)) on the residual enzyme activity (REA). The maximum REA of 38.7% was obtained at T = 50 °C and Q = 1.4. To investigate the drying effect on the catalytic activity, the optimum reaction conditions (pH and temperature), as well as kinetic parameters, were investigated for the fresh and dried enzyme extracts (FEE and DEE). The obtained results showed that the optimum pH of DEE was decreased by 12.3% compared to FEE, while the optimum temperature of DEE compared to FEE increased by a factor of 85.7%. Moreover, kinetic parameters, thermal-stability, and shelf life of the enzyme were considerably improved after drying by the spouted bed. Overall, the results confirmed that a spouted bed reactor can be used as a promising method for drying heat-sensitive materials such as peroxidase enzyme.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1153
Author(s):  
Franz Konstantin Fuss ◽  
Asliza Ahmad ◽  
Adin Ming Tan ◽  
Rizal Razman ◽  
Yehuda Weizman

Hard-shell thoracolumbar sacral orthoses (TLSOs) are used for treating idiopathic scoliosis, a deformation of the spine with a sideways curvature. The pressure required inside the TLSO for ideal corrective results remains unclear. Retrofitting TLSOs with commercially available pressure measurement systems is expensive and can only be performed in a laboratory. The aim of this study was to develop a cost-effective but accurate pressure sensor system for TLSOs. The sensor was built from a piezoresistive polymer, placed between two closed-cell foam liners, and evaluated with a material testing machine. Because foams are energy absorbers, the pressure-conductance curve was affected by hysteresis. The sensor was calibrated on a force plate with the transitions from loading to unloading used to establish the calibration curve. The root mean square error was 12% on average within the required pressure range of 0.01–0.13 MPa. The sensor reacted to the changing pressure during breathing and different activities when tested underneath a chest belt at different tensions. The peak pressure reached 0.135 MPa. The sensor was further tested inside the scoliosis brace during different activities. The measured pressure was 0.014–0.124 MPa. The results from this study enable cheaper and mobile systems to be used for clinical studies on the comfort and pressure of braces during daily activities.


2011 ◽  
Vol 383-390 ◽  
pp. 1470-1476
Author(s):  
Hao Wang ◽  
Ding Guo Shao ◽  
Lu Xu

Lithium battery has been employed widely in many industrial applications. Parameter mismatches between lithium batteries along a series string is the critical limits of the large-scale applications in high power situation. Maintaining equalization between batteries is the key technique in lithium batteries application. This paper summarizes normal equalization techniques and proposed a new type of lithium Battery Equalization and Management System (BEMS) employing the isolated DC-DC converter structure. The system is integrated both equalization functions and management functions by using distributed 3-level controlled structure and digital control technique. With this control method the flexibility of the balance control strategy and the compatibility for different battery strings are both improved dramatically. The experimental results show optimizing equalization, efficiency and the battery string life span has been extended.


Robotica ◽  
2000 ◽  
Vol 18 (3) ◽  
pp. 299-303 ◽  
Author(s):  
Carl-Henrik Oertel

Machine vision-based sensing enables automatic hover stabilization of helicopters. The evaluation of image data, which is produced by a camera looking straight to the ground, results in a drift free autonomous on-board position measurement system. No additional information about the appearance of the scenery seen by the camera (e.g. landmarks) is needed. The technique being applied is a combination of the 4D-approach with two dimensional template tracking of a priori unknown features.


2018 ◽  
Vol 51 (4) ◽  
pp. 291-336 ◽  
Author(s):  
Antimo Graziano ◽  
Shaffiq Jaffer ◽  
Mohini Sain

Blends of polyethylene (PE) and polypropylene (PP) have always been the subject of intense reasearch for encouraging polymer waste recycling while producing new materials for specific applications in a sustainable way. However, being thermodynamically immiscible, these polyolefins form a binary system usually exhibiting lower performances compared with those of the homopolymers. Many studies have been carried out to better understand the PE/PP blend compatibilization for developing a high-performance and cost-effective product. Both nonreactive and reactive compatibilization promote the brittle to ductile transition for a PE/PP blend. However, the final product usually does not meet the requirements for high demanding commercial applications. Therefore, further PE/PP modification with a reinforcing filler, being either synthetic or natural, proved to be a good method for manufacturing high-performance reinforcend polymer blend composites, with superior and tailored properties. This review summarizes the recent progress in compatibilization techniques applied for enhancing the interfacial adhesion between PE and PP. Moreover, future perspectives on better understanding the influence of themodynamics on PE/PP synergy are discussed to introduce more effective compatibilization strategies, which will allow this blend to be used for innovative industrial applications.


1991 ◽  
Vol 219 ◽  
Author(s):  
T. Horikawa ◽  
S. Tahata ◽  
S. Kaho ◽  
T. Masumi ◽  
N. Mikami ◽  
...  

ABSTRACTA new type of ferroelectric liquid crystal light valve (FLCLV) is presented. The design of the FLCLV is based upon the linear equivalent circuit analyses. A photosensor in the FLCLV consists of a metal-insulator-semiconductor (MIS) photodiode. A-Si:H doped with boron and nitrogen [a-Si:(:N:B)] is used in the MIS diode. The a-Si:H(:B:N) film has a dark-conductivity of less than 1×1012 S/cm and a high photosensitivity.Consequently, the writing characteristics of the FLCLV for a two dimensional (2D) image are evaluated. Using writing light of 630 nm and 1 mW/cm2, a high resolution capability of 120∼140 1p/mm is obtained.


2014 ◽  
Vol 71 (9) ◽  
pp. 2530-2538 ◽  
Author(s):  
Emmanuel de Braux ◽  
Fletcher Warren-Myers ◽  
Tim Dempster ◽  
Per Gunnar Fjelldal ◽  
Tom Hansen ◽  
...  

Abstract Otolith marking with enriched stable isotopes via immersion is a recent method of batch marking larval fish for a range of research and industrial applications. However, current immersion times and isotope concentrations required to successfully mark an otolith limit the utility of this technique. Osmotic induction improves incorporation and reduces immersion time for some chemical markers, but its effects on isotope incorporation into otoliths are unknown. Here, we tested the effects of osmotic induction over a range of different isotope concentrations and immersion times on relative mark success and strength for 26Mg:24Mg, 86Sr:88Sr and 137Ba:138Ba on Atlantic salmon (Salmo salar) larvae. 71% and 100% mark success were achieved after 1 h of immersion for 86Sr (75 µg L−1) and 137Ba (30 µg L−1) isotopes, respectively. Compared with conventional immersion, osmotic induction improved overall mark strength for 86Sr and 137Ba isotopes by 26–116%, although this effect was only observed after 12 h of immersion and predominately for 86Sr. The results demonstrate that osmotic induction reduces immersion times and the concentrations of isotope required to achieve successful marks. Osmotically induced isotope labels via larval immersion may prove a rapid and cost-effective way of batch marking fish larvae across a range of potential applications.


2022 ◽  
Author(s):  
Hao Kong ◽  
Yun Chen ◽  
Guozheng Yang ◽  
Bin Liu ◽  
Lei Guo ◽  
...  

Environmental pollution is a global problem that endangers human health and ecological balance. As a new type of nanomaterial, two-dimensional material (2DM)-based aerogel is one of the most promising candidates...


Sign in / Sign up

Export Citation Format