scholarly journals Inactivation kinetics and steady-state current noise in the anomalous rectifier of tunicate egg cell membranes.

1978 ◽  
Vol 281 (1) ◽  
pp. 77-99 ◽  
Author(s):  
H Ohmori
2021 ◽  
Vol 11 (15) ◽  
pp. 6920
Author(s):  
Oldřich Coufal

Two infinitely long parallel conductors of arbitrary cross section connected to a voltage source form a loop. If the source voltage depends on time, then due to induction there is no constant current density in the loop conductors. It is only recently that a method has been published for accurately calculating current density in a group of long parallel conductors. The method has thus far been applied to the calculation of steady-state current density in a loop connected to a sinusoidal voltage source. In the present article, the method is used for an accurate calculation of transient current using transient current density. The transient current is analysed when connecting and short-circuiting the sources of sinusoidal, constant and sawtooth voltages. For circular cross section conductors, the dependences of maximum current density, maximum current and the time of achieving steady state on the source frequency, the distance of the conductors and their resistivity when connecting the source of sinusoidal voltage are examined.


Author(s):  
Gabriel Ybarra ◽  
Carlos Moina ◽  
María Inés Florit ◽  
Dionisio Posadas

<p class="PaperAbstract"><span lang="EN-US">In this work, the mediated reduction and oxidation of Fe(CN)<sub>6</sub><sup>3-/4-</sup> and Fe<sup>3+ </sup>in poly(o-aminophenol) coated electrodes is analyzed by means of diagnosis diagram based on the features of steady state current-potential curves. This analysis allows to identify the current determining process and to reproduce the experimental characteristics of the polarization curve from the relevant kinetic and thermodynamical parameters with a minimum amount of experimental measurements. </span></p>


2003 ◽  
Vol 785 ◽  
Author(s):  
C. Bielmeier ◽  
W. Walter

ABSTRACTThe development of lightweight low power consumption actuators is critical to the development of micro-robotics. Electroactive Polymers (EAP), i.e. Nafion N-117, meet these requirements. In the actuation of an EAP, the current does not remain constant over time. The development of a circuit model of current draw over time to best predict a current dynamic has been explored. While the material mimics a parallel plate capacitor, it has been found that capacitance plays no role in achieving steady state current levels. This development is critical to understanding and developing the material as an actuator.


1984 ◽  
Vol 4 (2) ◽  
pp. 241-249 ◽  
Author(s):  
Albert Gjedde ◽  
Ove Christensen

Tracer studies on facilitated diffusion across the blood–brain barrier lead to the calculation of Michaelis-Menten constants that describe the rate of transport. However, the barrier consists of two endothelial cell membranes, and the relevance of single Michaelis-Menten constants in relation to the two cell membranes is unknown. We have formulated a model of two endothelial cell membranes and show that the measured Michaelis-Menten constants are simple functions of the properties of the individual membranes when transport across the endothelium is rapid ( P1 > 10−6 cm s−1). We also show that the Michaelis-Menten constants determined in tracer experiments describe facilitated diffusion in the steady state only if the two membranes have similar transport properties. As an application of this observation, we have examined three experimental studies that measure glucose transport in the steady state and show that the Michaelis-Menten constants for glucose transport calculated from the tracer experiments are equal to the constants calculated from the steady-state experiments. We conclude that the luminal and abluminal membranes of brain capillary endothelial cells have equal glucose transport properties.


Sign in / Sign up

Export Citation Format

Share Document