scholarly journals The absolute value of the isometric heat coefficient determined by means of high-frequency calibration of the living muscle

1934 ◽  
Vol 81 (3) ◽  
pp. 361-371 ◽  
Author(s):  
H. Rosenberg
Author(s):  
Prajanto Wahyu Adi ◽  
Yani Parti Astuti ◽  
Egia Rosi Subhiyakto

The main objective of watermarking method is to improve the robustness and imperceptibility. This paper introduces an improved CRT watermarking method using absolute value of interpolated wavelet coefficients aiming to improve the imperceptibility and robustness. The standard CRT method embeds the watermark bits on the blocks of pixels evenly. Hence, it can significantly reduce the quality of watermarked images when the watermark lies on the homogeneous area. Otherwise, the proposed method is embedding the watermark bits on the heterogeneous area by sorting the absolute magnitude of wavelet coefficients descending. The waveletcoefficients are selected from high frequency wavelet sub band HH. This scheme is able to determine the appropriate embedding location in certain range of value. The watermark bits are then embedding on the selectedpixel value using CRT scheme. The result shows that the average imperceptibility value the CRT is 0.9980 while the proposed method has average value of 0.9993. On robustness against compression, the proposed method achieves better result compared to the CRT with the average NC values of 0.7916 higher than the CRT value of 0.7530. These prove that the proposed method has better performance in term of imperceptibility and robustness against compression than the CRT method.


2020 ◽  
Vol 11 (1) ◽  
pp. 20
Author(s):  
Muhammad Ikbal Abdullah ◽  
Andi Chairil Furqan ◽  
Nina Yusnita Yamin ◽  
Fahri Eka Oktora

This study aims to analyze the sensitivity testing using measurements of realization of regional own-source revenues and operating expenditure and to analyze the extent of the effect of sample differences between Java and non-Java provinces by using samples outside of Java. By using sensitivity analysis, the results found the influence of audit opinion on the performance of the provincial government mediated by the realization of regional operating expenditure. More specifically, when using the measurement of the absolute value of the realization of regional operating expenditure it was found that there was a direct positive and significant influence of audit opinion on the performance of the Provincial Government. However, no significant effect of audit opinion was found on the realization value of regional operating expenditure and the effect of the realization value of regional operating expenditure on the performance of the Provincial Government. This result implies that an increase in audit opinion will be more likely to be used as an incentive for the Provincial Government to increase the realization of regional operating expenditure.


1977 ◽  
Vol 32 (11-12) ◽  
pp. 908-912 ◽  
Author(s):  
H. J. Schmidt ◽  
U. Schaum ◽  
J. P. Pichotka

Abstract The influence of five different methods of homogenisation (1. The method according to Potter and Elvehjem, 2. A modification of this method called Potter S, 3. The method of Dounce, 4. Homogenisation by hypersonic waves and 5. Coarce-grained homogenisation with the “Mikro-fleischwolf”) on the absolute value and stability of oxygen uptake of guinea pig liver homogenates has been investigated in simultaneous measurements. All homogenates showed a characteristic fall of oxygen uptake during measuring time (3 hours). The modified method according to Potter and Elvehjem called Potter S showed reproducible results without any influence by homogenisation intensity.


Open Physics ◽  
2021 ◽  
Vol 19 (1) ◽  
pp. 11-17
Author(s):  
Nikolay Kryukov ◽  
Eugene Oks

Abstract In the literature, there were studies of Rydberg states of hydrogenic atoms/ions in a high-frequency laser field. It was shown that the motion of the Rydberg electron is analogous to the motion of a satellite around an oblate planet (for a linearly polarized laser field) or around a (fictitious) prolate planet (for a circularly polarized laser field): it exhibits two kinds of precession – one of them is the precession within the orbital plane and another one is the precession of the orbital plane. In this study, we study a helium atom or a helium-like ion with one of the two electrons in a Rydberg state, the system being under a high-frequency laser field. For obtaining analytical results, we use the generalized method of the effective potentials. We find two primary effects of the high-frequency laser field on circular Rydberg states. The first effect is the precession of the orbital plane of the Rydberg electron. We calculate analytically the precession frequency and show that it differs from the case of a hydrogenic atom/ion. In the radiation spectrum, this precession would manifest as satellites separated from the spectral line at the Kepler frequency by multiples of the precession frequency. The second effect is a shift of the energy of the Rydberg electron, also calculated analytically. We find that the absolute value of the shift increases monotonically as the unperturbed binding energy of the Rydberg electron increases. We also find that the shift has a nonmonotonic dependence on the nuclear charge Z: as Z increases, the absolute value of the shift first increases, then reaches a maximum, and then decreases. The nonmonotonic dependence of the laser field-caused energy shift on the nuclear charge is a counterintuitive result.


Author(s):  
PALOMA BENGOECHEA

Abstract We refine a previous construction by Akhtari and Bhargava so that, for every positive integer m, we obtain a positive proportion of Thue equations F(x, y) = h that fail the integral Hasse principle simultaneously for every positive integer h less than m. The binary forms F have fixed degree ≥ 3 and are ordered by the absolute value of the maximum of the coefficients.


The values of gravity at these stations have been compared by means of pendulum observations with Invar invariable pendulums. The observed differences of gravity from the National Physical Laboratory are: B. I. P. M. -256·73 ± 0·49 mgal P. T. B. + 68·68 ± 0·49 mgal Bad Harzburg - 15·68 ± 0·49 mgal The accuracy of the measurements is not so great as has been achieved once or twice previously with the same apparatus, mainly because the changes in the lengths of the pendulums were greater than usual. These differences have been combined with German pendulum observations and with gravimeter comparisons with the following results: Value of gravity at N. P. L. on the Potsdam system: 981196·29 ± 0·3 mgal. Differences between sites of absolute determinations of gravity: N. P. L. - B. I. P. M. +256·45 ± 0·3 mgal N. P. L. - P. T. B. - 68·98 ± 0·3 mgal P. T. B. - Potsdam - 8·95 ± 0·4 mgal ( g at Potsdam = 981274 mgal.) The effects of these results on gravity surveys based on Cambridge and on the absolute value of gravity are indicated.


1996 ◽  
Vol 35 (6) ◽  
pp. 830-838 ◽  
Author(s):  
Jingping Duan ◽  
Michael Bevis ◽  
Peng Fang ◽  
Yehuda Bock ◽  
Steven Chiswell ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document