Detection of Sizes and Locations Air Voids in Reinforced Concrete Slab using Ground Penetrating Radar and Impact-Echo Methods

2015 ◽  
Vol 74 (3) ◽  
Author(s):  
Nurhayati Abdul Razak ◽  
Syahrul Fithry Senin ◽  
Roszilah Hamid

 The presence of inevitable air void defects in reinforced concrete components due to poor quality control during construction can further aggravate the moisture and chloride penetration in concrete to accelerate the corrosion process of the reinforcing steel. Non-destructive test  (NDT) methods, Ground Penetrating Radar (GPR) and Impact-Echo (IE), are utilised tp detect the void defects. This study is to compare the accuracy and limitations of both methods in detecting the sizes and depths of the air voids. The sample is a 600 × 400 ×200 mm3 reinforced grade 40 concrete slab with embedded air voids in the sample. The air-voids are introduced in the concrete slab by positioning air-void plastic balls with diameters of 67, 45, 27, 20 and 3 mm each at the depths of 70, 80, 100, 80 and 80 mm, respectively, from the top surface of the slab. Results show that GPR can detect the air voids with sizes larger than 20 mm in diameter with error ranging from -8.9 to 30% from their actual diameters. The IE method is only able to detect the air voids depths and not the voids’ sizes. It is also observed that the void depth estimation acquired by GPR is more accurate only for large size void (67 mm), but for sizes less than that, IE is more accurate in determining their locations. Both methos should be considered for NDT application in detecting voids depending on which parameter accuracy is inticipated.  

Sensors ◽  
2020 ◽  
Vol 20 (20) ◽  
pp. 5838
Author(s):  
Changkye Lee ◽  
Seong-Hoon Kee ◽  
Jun Won Kang ◽  
Byong-Jeong Choi ◽  
Jin Woo Lee

The main objectives of this study are to investigate the spectral responses of a fire-damaged concrete slab using Impact-echo (IE) testing, and to develop a simplified model for interpreting the frequency shift due to heat-induced concrete damage after the fire. For these purposes, a reinforced concrete slab specimen (1000 mm (width) by 5000 mm (length) by 210 mm (thickness)) was fabricated in the laboratory. Heat damage in the concrete slab specimen was induced by exposing the bottom of the specimen to the temperatures corresponding to the standard fire curve described in the ASTM E 119 for 3 h. Impact-echo testing was performed on the bottom surface of the concrete slab specimen before and after inducing the fire damage. It was observed that the spectral responses of the fire-damaged concrete were dominated by several non-propagating waves, which resulted in main peak frequencies around 4500 Hz and 5100 Hz. A discrete layered concrete damage model developed in this study was used to reconstruct the variation of the P-wave velocity with the depth of the fire-damaged concrete. It was demonstrated that the predicted P-wave velocity profile using the simplified model showed a good agreement with the measured values from the five core samples, which measured 100 mm (diameter) by 200 mm (height) cylinders, using ultrasonic pulse velocity (UPV) measurements at eight different depths. In addition, the peak frequencies predicted by the simplified model were consistent with the measured peak frequencies. The experimental results in this study demonstrated that IE testing is effective for evaluating the post-fire damage of reinforced concrete slabs. Particularly, the simplified model in this study can be effective for better interpreting the spectral responses of fire-damaged concrete slabs by IE testing.


Author(s):  
Ralph Alan Dusseau

The results of a study funded by the U.S. Geological Survey as part of the National Earthquake Hazards Reduction Program are presented. The first objective of this study was the development of a database for all 211 highway bridges along I-55 in the New Madrid region of southeastern Missouri. Profiles for five key dimension parameters (which are stored in the database) were developed, and the results for concrete highway bridges are presented. The second objective was to perform field ambient vibration analyses on 25 typical highway bridge spans along the I-55 corridor to determine the fundamental vertical and lateral frequencies of the bridge spans measured. These 25 spans included six reinforced concrete slab spans and two reinforced concrete box-girder spans. The third objective was to use these bridge frequency results in conjunction with the dimension parameters stored in the database to develop empirical formulas for estimating bridge fundamental natural frequencies. These formulas were applied to all 211 Interstate highway bridges in southeastern Missouri. Profiles for both fundamental vertical and lateral frequencies were then developed, and the results for concrete highway bridges are presented.


1985 ◽  
Vol 50 ◽  
Author(s):  
A. Atkinson ◽  
D. J. Goult ◽  
J. A. Hearne

AbstractA preliminary assessment of the long-term durability of concrete in a repository sited in clay is presented. The assessment is based on recorded experience of concrete structures and both field and laboratory studies. It is also supported by results of the examination of a concrete sample which had been buried in clay for 43 years.The enoineering lifetime of a 1 m thick reinforced concrete slab, with one face in contact with clay, and the way in which pH in the repository as a whole is likely to vary with time have both been estimated from available data. The estimates indicate that engineering lifetimes of about 103 years are expected (providing that sulphate resisting cement is used) and that pH is likely to remain above 10.5 for about 106 years.


2014 ◽  
Vol 606 ◽  
pp. 229-232 ◽  
Author(s):  
Petr Tej ◽  
Vítězslav Vacek ◽  
Jiří Kolísko ◽  
Jindřich Čech

The paper focuses on a computer nonlinear analysis of the formation and development of cracks in a concrete slab exposed to a uniform continuous load on the lower surface. The analysis is based on an actual example of the formation and development of cracks in a basement slab exposed to ground water buoyancy.


1999 ◽  
pp. 251-259
Author(s):  
Shigenori YUYAMA ◽  
Zhang-Wang LI ◽  
Takeshi TOMOKIYO ◽  
Masaru YOSHIZAWA ◽  
Taketo UOMOTO

2013 ◽  
Vol 405-408 ◽  
pp. 1815-1819
Author(s):  
Wen Sheng Yu ◽  
Zhu Long Li ◽  
Xiao Ru Xie ◽  
Li Yuan Guo

To analyze the earth pressure of corrugated steel culvert under high fill embankment, a field test was taken and the change law was got with the filling height increasing, the force state when geotechnical grilles were laid on the top of corrugated steel culvert was compared to that of reinforced concrete slab culvert. Results show that the pressure on the top of corrugated steel culvert is smaller than that on the external in same level when test points are near to culvert, the values of test points above and below geotechnical grilles are close, and the pressure of corrugated steel culvert is smaller than that of reinforced concrete slab culvert when filling height is above 7.3 m. So analysis indicates corrugated steel culvert spreads the upper load better, the geotechnical grille can reduce the pressure effectively through earth pressure redistribution, and the mechanical property of corrugated steel culvert is better than reinforced concrete slab culvert under high fill embankment.