What periodontal recall interval is supported by evidence?

2020 ◽  
Vol 84 (1) ◽  
pp. 124-133 ◽  
Author(s):  
Leonardo Trombelli ◽  
Anna Simonelli ◽  
Giovanni Franceschetti ◽  
Elisa Maietti ◽  
Roberto Farina
Keyword(s):  
Author(s):  
Roberto Farina ◽  
Anna Simonelli ◽  
Andrea Baraldi ◽  
Mattia Pramstraller ◽  
Luigi Minenna ◽  
...  

Abstract Objectives To evaluate yearly tooth loss rate (TLR) in periodontitis patients with different periodontal risk levels who had complied or not complied with supportive periodontal care (SPC). Materials and methods Data from 168 periodontitis patients enrolled in a SPC program based on a 3-month suggested recall interval for at least 3.5 years were analyzed. For patients with a mean recall interval within 2–4 months (“compliers”) or > 4 months (“non-compliers”) with different PerioRisk levels (Trombelli et al. 2009), TLR (irrespective of the cause for tooth loss) was calculated. TLR values were considered in relation to meaningful TLR benchmarks from the literature for periodontitis patients either under SPC (0.15 teeth/year; positive benchmark) or irregularly complying with SPC (0.36 teeth/year; negative benchmark). Results In both compliers and non-compliers, TLR was significantly below or similar to the positive benchmark in PerioRisk level 3 (0.08 and 0.03 teeth/year, respectively) and PerioRisk level 4 (0.12 and 0.18 teeth/year, respectively). Although marked and clinically relevant in non-compliers, the difference between TLR of compliers (0.32 teeth/year) and non-compliers (0.52 teeth/year) with PerioRisk level 5 and the negative benchmark was not significant. Conclusion A SPC protocol based on a 3- to 6-month recall interval may effectively limit long-term tooth loss in periodontitis patients with PerioRisk levels 3 and 4. A fully complied 3-month SPC protocol seems ineffective when applied to PerioRisk level 5 patients. Clinical relevance PerioRisk seems to represent a valid tool to inform the SPC recall interval as well as the intensity of active treatment prior to SPC enrollment.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 1159-1159
Author(s):  
Fernanda Leite ◽  
Ângela Leite ◽  
Sara Ferreira ◽  
Jorge Coutinho

Introduction: Among patients receiving vitamin K antagonists (VKA) therapy, maintenance of an international normalized ratio (INR) in the therapeutic range is essential for treatment efficacy and safety. This requires regular monitoring and appropriate dose adjustment. It has been reported that anticoagulation clinics should aim for a time in therapeutic range (TTR) between 70-80% to optimize benefit and minimize the risk of adverse events. Previously (in a study between September 2006 and June 2012), we have reported that patients with longer INR recall interval (4-8 weeks) showed no decrease of monitoring quality and that it would be safe to increase time between measurements. Aim: Since actual recommendations for improving TTR include shortening INR recall interval (Lip et al. 2018) we aimed to evaluate the quality of anticoagulation monitoring after having increased time between measurements beyond the 4-8 weeks recall interval. Methodology: We retrospectively analyzed 37931 appointments of 6 consecutive years (July 2012 to July 2018) corresponding to 1587 patients that are regularly followed up at an outpatient Anticoagulation Clinic of a central hospital under anticoagulation for at least 8 weeks, using TTR determined by Rosendaal method. Patients were divided according to target INR in three groups: Group 1 with target INR 2-3, including 1430 patients corresponding to 30743 appointments with mean age 69±15 years (mean±SD), majority (46.4%) with atrial fibrillation (AF); Group 2 with target INR 2.5-3.5, including 125 patients corresponding to 5439 appointments with mean age 67±12 years, majority (85.6%) with mechanical heart valves; Group 3 with target INR 3-4, including 32 patients corresponding to 1749 appointments with mean age 62±14 years, majority (62.5%) with antiphospholipid syndrome. Descriptive statistics (mean, standard deviation, minimum, maximum, chi-square), inferential statistics (t-test, A-Nova and effect sizes) tests and correlations were performed. Results: The 1587 patient population, 50.5% male, mean age of 68±17 years and 90.1% in Group 1, showed a mortality of 18%. A point-biserial correlation was run to determine the relationship between mortality and gender, age, INR group and diagnostic. Mortality was correlated with diagnosis (57.2% with AF) (rpb = -.071, n = 1587, p = .004), male gender (60%) (rpb = -.089, n = 1587, p <.001) and age (75±12) (rpb = .175, n= 1587, p<.001) but not with INR group (rpb = -.017, n = 1587, p = .499). Indeed, between groups mortality was not different [Χ2(2)=.492; p=.782; φ=.018] nor mean age [F(2, 1584)=2.588; p=.078; η2=.003], but gender distribution was unequal [Χ2(2)= 10.815; p=.004; φ=.083] with male predominating in Group 1 (51.9%) and female in Group 2 (60.8%) and 3 (65.6%). Patients in Group 1, corresponding to 90.1% of the total population, had TTR of 72%, patients in Group 2 had TTR of 69% and patients in Group 3 had TTR of 60%. Comparatively to the previous study (2006-2012), we noticed a significant decrease in patient population / appointments size (2087/ 61988) (p <.001) with a decrease of TTR in Group 1 (1927 patients) (83%) and Group 2 (120 patients) (74%) but a TTR increase in Group 3 (40 patients) (54%) (p <.001). Conclusions and Discussion: More than 90% of the population under VKA treatment showed effective TTR which may infer safety in increasing INR recall interval. The TTR decrease with a smaller population may be explained by the introduction of direct oral anticoagulants in patients with less comorbidities. The increase of TTR in patients with higher INR target suggests a better management of patients under VKA therapy that is actually the only choice for challenging patients. Disclosures No relevant conflicts of interest to declare.


2020 ◽  
Vol 9 (4) ◽  
pp. 984 ◽  
Author(s):  
Amina Munir ◽  
Matthias Zehnder ◽  
Dan-Krister Rechenberg

The aim of this study was to systematically review pulp wound lavage in vital pulp therapy (VPT). A search was conducted in six life science databases to identify clinical trials carried out on permanent teeth with a carious pulp exposure and a recall interval of at least six months. Twenty-seven trials of low to moderate risk of bias (RoB-2 and ROBINS-I) were included. Data was extracted and analyzed regarding study characteristics and methods used for pulp wound lavage. The agent used for pulp wound lavage was specified in all included trials. Most of the identified trials (23/27) randomized the pulp capping material. Many (14/27) reported the use of sodium hypochlorite (NaOCl); ten used only saline or water. One trial was identified that compared pulp wound lavage with 2.5% (NaOCl) to saline, another compared 5% glutaraldehyde to water, both in immature molar pulpotomies. Both studies were underpowered. Neither showed a significant difference between treatments. The use of NaOCl was positively correlated to recent year of publication and use of hydraulic calcium silicate cements for pulp capping (p < 0.05). In conclusion, despite a lack of well-designed trials on pulp wound lavage in VPT, a trend towards using NaOCl for this purpose was observed.


2015 ◽  
Vol 15 (4) ◽  
pp. 171-181 ◽  
Author(s):  
Owais A. Farooqi ◽  
Carolyn J. Wehler ◽  
Gretchen Gibson ◽  
M. Marianne Jurasic ◽  
Judith A. Jones

2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Angelika Rauch ◽  
Sebastian Mehlhorn ◽  
Manja Mühle ◽  
Dirk Ziebolz

Combined periodontal and prosthodontic treatment demands of patients require a structured coordination of pretreatments and an adequate choice of restorations. This is especially true if multiple teeth are missing and insufficient crown-root ratios are obvious. A 40-year-old patient with a severe periodontitis (Stage IV, Grade C) was treated with active, nonsurgical periodontal therapy. Afterwards, a supportive periodontal therapy was provided with a recall interval of three to four months. Due to a high tooth mobility of the anterior teeth in the upper jaw and a missing left canine, a combination of a resin composite (Signum composite, Kulzer, Hanau, Germany) and a unidirectional glass prepreg fiber (Tender Fiber Quattro, MICERIUM, Avegno, Italy) was utilized to fabricate a splint in a labside approach to stabilize the remaining teeth. Moreover, an artificial denture tooth was adhesively luted to the splint. A temporary polymer-based material (Vita CAD-Temp, VITA Zahnfabrik, Bad Säckingen, Germany) was selected to supply the posterior teeth of the patient with a 3-unit fixed dental prosthesis (FDP), and both restorations were adhesively cemented. 19 months after insertion, a fracture of the fiber-reinforced resin composite splint occurred that was intraorally repaired. In spite of the fracture of the splint, all materials were functionally and esthetically stable over the follow-up period of 22 months.


1972 ◽  
Vol 24 (4) ◽  
pp. 378-385 ◽  
Author(s):  
Laird S. Cermak

The subjects were divided into three groups with respect to their expectations concerning a recall task given after the final trial of the usual STM distractor procedure. Group 1 were told only that they would have to recall during each trial's recall interval, thus did not expect to have to recall again. Group 2 were told that they would have to recall all the words presented in the experiment at the end of the last trial, in addition to the trial-by-trial recall. Group 3 were told only that they would have to recall after all words had been presented and they sat passively through the presentation trials. In addition to their recall expectations, half of the subjects in each group received a 2-s presentation and half received a 5-s presentation interval. It was found that the length of the presentation interval had an effect on the number of words recalled at the end of all trials, but recall expectancy did not. However, expectancy did determine the rehearsal strategies of subjects and hence the serial positions from which items were recalled.


1987 ◽  
Vol 78 (1) ◽  
pp. 79-89 ◽  
Author(s):  
Eileen B. Jones ◽  
J. G. O'Gorman ◽  
Brian Byrne
Keyword(s):  

1968 ◽  
Vol 20 (1) ◽  
pp. 79-82 ◽  
Author(s):  
Bennet B. Murdock

This paper deals with the problem of the interpretation of response latencies in short-term memory. A paired-associate study using a probe technique was conducted with the main experimental variation the length of the recall interval (1, 2, or 4 sec.). While shortening the interval had a statistically significant effect on recall probability the interaction between recall interval and probe position was negligible. While traditionally response latency is considered a measure of associative strength, such an interpretation seems inappropriate here. As an alternative, latencies may reflect more criterion values than sensitivity as these measures are interpreted in signal-detection theory.


Sign in / Sign up

Export Citation Format

Share Document