Digital to Analog Facially Generated Interchangeable Facebow Transfer: Capturing a Standardized Reference Position

2021 ◽  
Author(s):  
John C. Kois ◽  
Dean E. Kois ◽  
Jonathan M. Zeitler ◽  
Jean Martin
2020 ◽  
pp. 15-23
Author(s):  
V. M. Grechishnikov ◽  
E. G. Komarov

The design and operation principle of a multi-sensor Converter of binary mechanical signals into electrical signals based on a partitioned fiber-optic digital-to-analog Converter with a parallel structure is considered. The digital-to-analog Converter is made from a set of simple and technological (three to five digit) fiber-optic digital-to-analog sections. The advantages of the optical scheme of the proposed. Converter in terms of metrological and energy characteristics in comparison with single multi-bit converters are justified. It is shown that by increasing the number of digital-analog sections, it is possible to repeatedly increase the information capacity of a multi-sensor Converter without tightening the requirements for its manufacturing technology and element base. A mathematical model of the proposed Converter is developed that reflects the features of its operation in the mode of sequential time conversion of the input code vectors of individual fiber-optic sections into electrical analogues and the formation of the resulting output code vector.


2011 ◽  
Vol 70 (2) ◽  
pp. 159-169
Author(s):  
A. N. Rudyakova ◽  
A. Yu. Lipinsky ◽  
V. V. Danilov

2019 ◽  
pp. 84-92
Author(s):  
Anh Chi Phan ◽  
Xuan Anh Ngoc Ho

Background: The condylar position discrepancy between centric relation and maximal intercuspation has been still a controversial issue. Aims: To compare the condylar position between centric relation and maximal intercuspation using cone-beam tomography in patients without temporomandibular joints disorder. Materials and methods: To assess the condylar position in centric relation and maximal intercuspation using cone-beam tomography on 40 fifth-year and sixth-year dental students of Hue University of Medicine and Pharmacy without temporomandibular joints disorder. The condylar positions are assessed following Sener classification (2009) and are compared between centric relation and maximal intercuspation using pairedsamples t-test and Mann-Whitney U-test. Results: Among 480 condye-to-fossa measurement pairs, there are 91.2% pairs having difference between two reference position but there is no significant difference. The condylar position at the superior of mandibular fossa has the greatest percentage in both centric relation and maximal intercuspation (43.8% in centric relation and 51.2% in maximal intercuspation). This greatest percentage is followed by the condylar position at posterior of mandibular fossa (32.5% in centric relation and 36.3% in maximal intercuspation). Lastly, the condylar position at the anterior of mandibular fossa has the fewest percentage (23.7% in centric relation and 12.5% in maximal intercuspation). Conclusion: There is no significant difference of condylar position between centric relation and maximal intercuspation in patients without temporomandibular joints disorder. Key words: Condylar position, centric relation, maximal intercuspation, cone-beam tomography


Sign in / Sign up

Export Citation Format

Share Document