scholarly journals Physiological in vitro sacroiliac joint motion: a study on three‐dimensional posterior pelvic ring kinematics

2018 ◽  
Vol 234 (3) ◽  
pp. 346-358 ◽  
Author(s):  
Niels Hammer ◽  
Mario Scholze ◽  
Thomas Kibsgård ◽  
Stefan Klima ◽  
Stefan Schleifenbaum ◽  
...  
2021 ◽  
Vol 10 (2) ◽  
pp. 184
Author(s):  
Maximilian Kerschbaum ◽  
Siegmund Lang ◽  
Florian Baumann ◽  
Volker Alt ◽  
Michael Worlicek

Insertion of sacro-iliac (SI) screws for stabilization of the posterior pelvic ring without intraoperative navigation or three-dimensional imaging can be challenging. The aim of this study was to develop a simple method to visualize the ideal SI screw corridor, on lateral two-dimensional images, corresponding to the lateral fluoroscopic view, used intraoperatively while screw insertion, to prevent neurovascular injury. We used multiplanar reconstructions of pre- and postoperative computed tomography scans (CT) to determine the position of the SI corridor. Then, we processed the dataset into a lateral two-dimensional slice fusion image (SFI) matching head and tip of the screw. Comparison of the preoperative SFI planning and the screw position in the postoperative SFI showed reproducible results. In conclusion, the slice fusion method is a simple technique for translation of three-dimensional planned SI screw positioning into a two-dimensional strict lateral fluoroscopic-like view.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Darius M. Thiesen ◽  
Dimitris Ntalos ◽  
Josephine Berger-Groch ◽  
Andreas Petersik ◽  
Bernhard Hofstätter ◽  
...  

2019 ◽  
Vol 2019 ◽  
pp. 1-12 ◽  
Author(s):  
Maziar Ramezani ◽  
Stefan Klima ◽  
Paul Le Clerc de la Herverie ◽  
Jean Campo ◽  
Jean-Baptiste Le Joncour ◽  
...  

Introduction. Computational modeling of the human pelvis using the finite elements (FE) method has become increasingly important to understand the mechanisms of load distribution under both healthy and pathologically altered conditions and to develop and assess novel treatment strategies. The number of accurate and validated FE models is however small, and given models fail resembling the physiologic joint motion in particular of the sacroiliac joint. This study is aimed at using an inverted validation approach, using in vitro load deformation data to refine an existing FE model under the same mode of load application and to parametrically assess the influence of altered morphology and mechanical data on the kinematics of the model. Materials and Methods. An osteoligamentous FE model of the pelvis including the fifth lumbar vertebra was used, with highly accurate representations of ligament orientations. Material properties were altered parametrically for bone, cartilage, and ligaments, followed by changes in bone geometry (solid versus 3 and 2 mm shell) and material models (linear elastic, viscoelastic, and hyperelastic isotropic), and the effects of varying ligament fiber orientations were assessed. Results. Elastic modulus changes were more decisive in both linear elastic and viscoelastic bone, cartilage, and ligaments models, especially if shell geometries were used for the pelvic bones. Viscoelastic material properties gave more realistic results. Surprisingly little change was observed as a consequence of altering SIJ ligament orientations. Validation with in vitro experiments using cadavers showed close correlations for movements especially for 3 mm shell viscoelastic model. Discussion. This study has used an inverted validation approach to refine an existing FE model, to give realistic and accurate load deformation data of the osteoligamentous pelvis and showed which variation in the outcomes of the models are attributed to altered material properties and models. The given approach furthermore shows the value of accurate validation and of using the validation data to fine tune FE models.


PLoS ONE ◽  
2016 ◽  
Vol 11 (2) ◽  
pp. e0148199 ◽  
Author(s):  
Miguel Pishnamaz ◽  
Christoph Wilkmann ◽  
Hong-Sik Na ◽  
Jochen Pfeffer ◽  
Christoph Hänisch ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Yongtao Lu ◽  
Yiqian He ◽  
Weiteng Li ◽  
Zhuoyue Yang ◽  
Ruifei Peng ◽  
...  

Background. A large number of pelvic injuries are seriously unstable, with mortality rates reaching 19%. Approximately 60% of pelvic injuries are related to the posterior pelvic ring. However, the selection of a fixation method for a posterior pelvic ring injury remains a challenging problem for orthopedic surgeons. The aim of the present study is to investigate the biomechanical performance of five different fixation approaches for posterior pelvic ring injury and thus provide guidance on the choice of treatment approach in a clinical setting. Methods. A finite element (FE) model, including the L3-L5 lumbar vertebrae, sacrum, and full pelvis, was created from CT images of a healthy adult. Tile B and Tile C types of pelvic fractures were created in the model. Five different fixation methods for fixing the posterior ring injury (PRI) were simulated: TA1 (conservative treatment), TA2 (S1 screw fixation), TA3 (S1 + S2 screw fixation), TA4 (plate fixation), and TA5 (modified triangular osteosynthesis). Based on the fixation status (fixed or nonfixed) of the anterior ring and the fixation method for PRI, 20 different FE models were created. An upright standing loading scenario was simulated, and the resultant displacements at the sacroiliac joint were compared between different models. Results. When TA5 was applied, the resultant displacements at the sacroiliac joint were the smallest (1.5 mm, 1.6 mm, 1.6 mm, and 1.7 mm) for all the injury cases. The displacements induced by TA3 and TA2 were similar to those induced by TA5. TA4 led to larger displacements at the sacroiliac joint (2.3 mm, 2.4 mm, 4.8 mm, and 4.9 mm), and TA1 was the worst case (3.1 mm, 3.2 mm, 6.3 mm, and 6.5 mm). Conclusions. The best internal fixation method for PRI is the triangular osteosynthesis approach (TA5), followed by S1 + S2 screw fixation (TA3), S1 screw fixation (TA2), and plate fixation (TA4).


Author(s):  
P.L. Moore

Previous freeze fracture results on the intact giant, amoeba Chaos carolinensis indicated the presence of a fibrillar arrangement of filaments within the cytoplasm. A complete interpretation of the three dimensional ultrastructure of these structures, and their possible role in amoeboid movement was not possible, since comparable results could not be obtained with conventional fixation of intact amoebae. Progress in interpreting the freeze fracture images of amoebae required a more thorough understanding of the different types of filaments present in amoebae, and of the ways in which they could be organized while remaining functional.The recent development of a calcium sensitive, demembranated, amoeboid model of Chaos carolinensis has made it possible to achieve a better understanding of such functional arrangements of amoeboid filaments. In these models the motility of demembranated cytoplasm can be controlled in vitro, and the chemical conditions necessary for contractility, and cytoplasmic streaming can be investigated. It is clear from these studies that “fibrils” exist in amoeboid models, and that they are capable of contracting along their length under conditions similar to those which cause contraction in vertebrate muscles.


Author(s):  
J. P. Revel

Movement of individual cells or of cell sheets and complex patterns of folding play a prominent role in the early developmental stages of the embryo. Our understanding of these processes is based on three- dimensional reconstructions laboriously prepared from serial sections, and from autoradiographic and other studies. Many concepts have also evolved from extrapolation of investigations of cell movement carried out in vitro. The scanning electron microscope now allows us to examine some of these events in situ. It is possible to prepare dissections of embryos and even of tissues of adult animals which reveal existing relationships between various structures more readily than used to be possible vithout an SEM.


Author(s):  
D. Reis ◽  
B. Vian ◽  
J. C. Roland

Wall morphogenesis in higher plants is a problem still open to controversy. Until now the possibility of a transmembrane control and the involvement of microtubules were mostly envisaged. Self-assembly processes have been observed in the case of walls of Chlamydomonas and bacteria. Spontaneous gelling interactions between xanthan and galactomannan from Ceratonia have been analyzed very recently. The present work provides indications that some processes of spontaneous aggregation could occur in higher plants during the formation and expansion of cell wall.Observations were performed on hypocotyl of mung bean (Phaseolus aureus) for which growth characteristics and wall composition have been previously defined.In situ, the walls of actively growing cells (primary walls) show an ordered three-dimensional organization (fig. 1). The wall is typically polylamellate with multifibrillar layers alternately transverse and longitudinal. Between these layers intermediate strata exist in which the orientation of microfibrils progressively rotates. Thus a progressive change in the morphogenetic activity occurs.


Sign in / Sign up

Export Citation Format

Share Document