Adapting the vertical position of implants with a conical connection in relation to soft tissue thickness prevents early implant surface exposure: A 2-year prospective intra-subject comparison

2018 ◽  
Vol 45 (5) ◽  
pp. 605-612 ◽  
Author(s):  
Stijn Vervaeke ◽  
Carine Matthys ◽  
Rima Nassar ◽  
Veronique Christiaens ◽  
Jan Cosyn ◽  
...  
2020 ◽  
Vol 9 (10) ◽  
pp. 3320
Author(s):  
Ron Doornewaard ◽  
Hugo de Bruyn ◽  
Carine Matthys ◽  
Ewald Bronkhorst ◽  
Stefan Vandeweghe ◽  
...  

Despite high success rates of dental implants, surface exposure may occur as a consequence of biologic width establishment associated with surgery. This prospective split-mouth study evaluated the effect of early implant surface exposure caused by initial bone remodeling on long-term peri-implant bone stability and peri-implant health. Additionally, Oral Health-Related Quality of Life (OHRQoL) was assessed by means of the Oral Health Impact Profile-14 (OHIP-14). Twenty-six patients received two non-splinted implants supporting an overdenture in the mandible by means of locators. One implant was installed equicrestally (control) and the second one was installed subcrestally, taking at least 3 mm soft tissue thickness into account (test). During initial bone remodeling (up to 6 months postoperatively), equicrestal placement yielded 0.68 mm additional surface exposure compared to subcrestal placement (p < 0.001). Afterwards, bone level and peri-implant health were comparable in both treatment conditions and stable up to 5 years. The implant overdenture improved OHRQoL (p < 0.01) and remained unchanged thereafter (p = 0.51). In conclusion, adapting the vertical position of the implant concerning the soft tissue thickness prevents early implant surface exposure caused by initial bone remodeling, but in a well-maintained population, this has no impact on long-term prognosis. The treatment of edentulousness with an implant mandibular overdenture improves OHRQoL.


2019 ◽  
Vol 8 (6) ◽  
pp. 773 ◽  
Author(s):  
Ron Doornewaard ◽  
Maarten Glibert ◽  
Carine Matthys ◽  
Stijn Vervaeke ◽  
Ewald Bronkhorst ◽  
...  

In fully edentulous patients, the support of a lower dental prosthesis by two implants could improve the chewing ability, retention, and stability of the prosthesis. Despite high success rates of dental implants, complications, such as peri-implantitis, do occur. The latter is a consequence of crestal bone loss and might be related to the implant surface and peri-implant soft tissue thickness. The aim of this paper is to describe the effect of implant surface roughness and soft tissue thickness on crestal bone remodeling, peri-implant health, and patient-centered outcomes. The mandibular overdenture supported by two implants is used as a split-mouth model to scrutinize these aims. The first study compared implants placed equicrestal to implants placed biologically (i.e., dependent on site-specific soft tissue thickness). The second clinical trial compared implants with a minimally to a moderately rough implant neck. Both studies reported an improvement in oral health-related quality of life and a stable peri-implant health after three years follow-up. Only equicrestal implant placement yielded significantly higher implant surface exposure, due to the establishment of the biologic width. Within the limitations of this study, it can be concluded that an implant supported mandibular overdenture significantly improves the quality of life, with limited biologic complications and high survival rates of the implants.


2019 ◽  
Vol 23 (3) ◽  
pp. 297-302 ◽  
Author(s):  
Julia D. Sharma ◽  
Kiran K. Seunarine ◽  
Muhammad Zubair Tahir ◽  
Martin M. Tisdall

OBJECTIVEThe aim of this study was to compare the accuracy of optical frameless neuronavigation (ON) and robot-assisted (RA) stereoelectroencephalography (SEEG) electrode placement in children, and to identify factors that might increase the risk of misplacement.METHODSThe authors undertook a retrospective review of all children who underwent SEEG at their institution. Twenty children were identified who underwent stereotactic placement of a total of 218 electrodes. Six procedures were performed using ON and 14 were placed using a robotic assistant. Placement error was calculated at cortical entry and at the target by calculating the Euclidean distance between the electrode and the planned cortical entry and target points. The Mann-Whitney U-test was used to compare the results for ON and RA placement accuracy. For each electrode placed using robotic assistance, extracranial soft-tissue thickness, bone thickness, and intracranial length were measured. Entry angle of electrode to bone was calculated using stereotactic coordinates. A stepwise linear regression model was used to test for variables that significantly influenced placement error.RESULTSBetween 8 and 17 electrodes (median 10 electrodes) were placed per patient. Median target point localization error was 4.5 mm (interquartile range [IQR] 2.8–6.1 mm) for ON and 1.07 mm (IQR 0.71–1.59) for RA placement. Median entry point localization error was 5.5 mm (IQR 4.0–6.4) for ON and 0.71 mm (IQR 0.47–1.03) for RA placement. The difference in accuracy between Stealth-guided (ON) and RA placement was highly significant for both cortical entry point and target (p < 0.0001 for both). Increased soft-tissue thickness and intracranial length reduced accuracy at the target. Increased soft-tissue thickness, bone thickness, and younger age reduced accuracy at entry. There were no complications.CONCLUSIONSRA stereotactic electrode placement is highly accurate and is significantly more accurate than ON. Larger safety margins away from vascular structures should be used when placing deep electrodes in young children and for trajectories that pass through thicker soft tissues such as the temporal region.


2021 ◽  
pp. 200460
Author(s):  
Diana Toneva ◽  
Silviya Nikolova ◽  
Stanislav Harizanov ◽  
Dora Zlatareva ◽  
Vassil Hadjidekov

Author(s):  
Mohammed Mousa Bakri ◽  
Sung Ho Lee ◽  
Jong Ho Lee

Abstract Background A compact passive oxide layer can grow on tantalum (Ta). It has been reported that this oxide layer can facilitate bone ingrowth in vivo though the development of bone-like apatite, which promotes hard and soft tissue adhesion. Thus, Ta surface treatment on facial implant materials may improve the tissue response, which could result in less fibrotic encapsulation and make the implant more stable on the bone surface. The purposes of this study were to verify whether surface treatment of facial implant materials using Ta can improve the biohistobiological response and to determine the possibility of potential clinical applications. Methods Two different and commonly used implant materials, silicone and expanded polytetrafluoroethylene (ePTFE), were treated via Ta ion implantation using a Ta sputtering gun. Ta-treated samples were compared with untreated samples using in vitro and in vivo evaluations. Osteoblast (MG-63) and fibroblast (NIH3T3) cell viability with the Ta-treated implant material was assessed, and the tissue response was observed by placing the implants over the rat calvarium (n = 48) for two different lengths of time. Foreign body and inflammatory reactions were observed, and soft tissue thickness between the calvarium and the implant as well as the bone response was measured. Results The treatment of facial implant materials using Ta showed a tendency toward increased fibroblast and osteoblast viability, although this result was not statistically significant. During the in vivo study, both Ta-treated and untreated implants showed similar foreign body reactions. However, the Ta-treated implant materials (silicone and ePTFE) showed a tendency toward better histological features: lower soft tissue thickness between the implant and the underlying calvarium as well as an increase in new bone activity. Conclusion Ta surface treatment using ion implantation on silicone and ePTFE facial implant materials showed the possibility of reducing soft tissue intervention between the calvarium and the implant to make the implant more stable on the bone surface. Although no statistically significant improvement was observed, Ta treatment revealed a tendency toward an improved biohistological response of silicone and ePTFE facial implants. Conclusively, tantalum treatment is beneficial and has the potential for clinical applications.