scholarly journals The IVAIRE project - a randomized controlled study of the impact of ventilation on indoor air quality and the respiratory symptoms of asthmatic children in single family homes

Indoor Air ◽  
2015 ◽  
Vol 25 (6) ◽  
pp. 582-597 ◽  
Author(s):  
P. Lajoie ◽  
D. Aubin ◽  
V. Gingras ◽  
P. Daigneault ◽  
F. Ducharme ◽  
...  
Energies ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 6470
Author(s):  
Walery Jezierski ◽  
Mirosław Zukowski ◽  
Beata Sadowska

This work presents the results of analysis of the final energy demand (Qk) for a single-family house in a pandemic situation and accompanying self-isolation of residents. It was assumed that the object of study is located in Bialystok (Poland). This analysis covers the impact of various factors such as specific periods of the active pandemic phase, the length of the inhabitants’ self-isolation period, the number of residents at home, and the type of energy source used in the building. Based on the results of computational experiments, a deterministic mathematical model of the relationship between these variables was developed, and the effects of the selected factors on the final energy demand were analyzed for the typical meteorological year (TMY) weather data. It turned out that the change in the length of the self-isolation period from 0 to 31 days caused an increase of Qk by about 6.5% for the analyzed building. When the number of inhabitants changed from 1 to 4, Qk increased by 34.7%. A change from 4 to 7 people causes an additional 26.7% increase in Qk. It was found that the structure of energy demand for this building operation during the period of inhabitants’ self-isolation also changed. With the increase in the length of the self-isolation period from 0 to 31 days, the electricity demand (Eel) increases by about 40–42%, while the demand for energy related to fuel consumption (Qg) decreases by about 7–10%. The article also presents an analysis of the impact of residents’ self-isolation on indoor air quality (IAQ) and thermal comfort. The simulation results showed that the use of variable air volume ventilation allows the CO2 concentration to be kept significantly below the limit value.


Atmosphere ◽  
2021 ◽  
Vol 12 (3) ◽  
pp. 400
Author(s):  
Tharwat Mokalled ◽  
Jocelyne Adjizian Gérard ◽  
Maher Abboud ◽  
Céline Liaud ◽  
Rouba Nasreddine ◽  
...  

In Beirut–Rafic Hariri International Airport (RHIA), airport employees stay at least 12 h inside the airport’s buildings and suffer from respiratory symptoms. Additionally, direct openings exist between the apron and the arrivals hall providing a pathway for contaminated air to enter the buildings. Hence, we study the impact of Beirut–RHIA’s activities on the indoor air of the arrivals hall (impact on employees and passengers) during June, November, and October 2014. Due to their impacts on air quality and human health, assessing of the concentrations of nitrogen dioxide (NO2) and Volatile Organic Compounds (VOCs) was the target of our study by using gas chromatographic techniques (GC-MS and GC-FID) for VOCs and calorimetric methods for NO2 concentrations. NO2 levels indicated a probable hazard to the health of passengers and employees, while measured VOC levels did not present any risks except for acrolein. This is the first study to assess the speciation of a large number of VOCs (46 VOCs) for airport indoor air while revealing a very interesting correlation between aircraft number and the concentrations of VOC groups (namely heavy alkanes, aldehydes and ketones, and monoaromatics). Moreover, this is the first study in Lebanon to assess the speciation of a large number of VOCs in indoor air.


2001 ◽  
Author(s):  
M. Phillips ◽  
N. Esmen ◽  
D. Johnson ◽  
T. Hall ◽  
R. Lynch ◽  
...  

2021 ◽  
Vol 13 (8) ◽  
pp. 4139
Author(s):  
Muriel Diaz ◽  
Mario Cools ◽  
Maureen Trebilcock ◽  
Beatriz Piderit-Moreno ◽  
Shady Attia

Between the ages of 6 and 18, children spend between 30 and 42 h a week at school, mostly indoors, where indoor environmental quality is usually deficient and does not favor learning. The difficulty of delivering indoor air quality (IAQ) in learning facilities is related to high occupancy rates and low interaction levels with windows. In non-industrialized countries, as in the cases presented, most classrooms have no mechanical ventilation, due to energy poverty and lack of normative requirements. This fact heavily impacts the indoor air quality and students’ learning outcomes. The aim of the paper is to identify the factors that determine acceptable CO2 concentrations. Therefore, it studies air quality in free-running and naturally ventilated primary schools in Chile, aiming to identify the impact of contextual, occupant, and building design factors, using CO2 concentration as a proxy for IAQ. The monitoring of CO2, temperature, and humidity revealed that indoor air CO2 concentration is above 1400 ppm most of the time, with peaks of 5000 ppm during the day, especially in winter. The statistical analysis indicates that CO2 is dependent on climate, seasonality, and indoor temperature, while it is independent of outside temperature in heated classrooms. The odds of having acceptable concentrations of CO2 are bigger when indoor temperatures are high, and there is a need to ventilate for cooling.


Author(s):  
Farhang Tahmasebi ◽  
Yan Wang ◽  
Elizabeth Cooper ◽  
Daniel Godoy Shimizu ◽  
Samuel Stamp ◽  
...  

The Covid-19 outbreak has resulted in new patterns of home occupancy, the implications of which for indoor air quality (IAQ) and energy use are not well-known. In this context, the present study investigates 8 flats in London to uncover if during a lockdown, (a) IAQ in the monitored flats deteriorated, (b) the patterns of window operation by occupants changed, and (c) more effective ventilation patterns could enhance IAQ without significant increases in heating energy demand. To this end, one-year’s worth of monitored data on indoor and outdoor environment along with occupant use of windows has been used to analyse the impact of lockdown on IAQ and infer probabilistic models of window operation behaviour. Moreover, using on-site CO2 data, monitored occupancy and operation of windows, the team has calibrated a thermal performance model of one of the flats to investigate the implications of alternative ventilation strategies. The results suggest that despite the extended occupancy during lockdown, occupants relied less on natural ventilation, which led to an increase of median CO2 concentration by up to 300 ppm. However, simple natural ventilation patterns or use of mechanical ventilation with heat recovery proves to be very effective to maintain acceptable IAQ. Practical application: This study provides evidence on the deterioration of indoor air quality resulting from homeworking during imposed lockdowns. It also tests and recommends specific ventilation strategies to maintain acceptable indoor air quality at home despite the extended occupancy hours.


2020 ◽  
pp. 1420326X2096076
Author(s):  
Pedro F. Pereira ◽  
Nuno M. M. Ramos

In Portugal, residential buildings commonly have their ventilation strategy changed after commissioning. This occurs due to the building managers' willingness to reduce shared costs with the electricity needed for fan operation. However, this option is not technically supported, and the effects of such a strategy on indoor air quality-related to human pollutants are yet to be quantified. CO2 was monitored in 15 bedrooms and air exchange rates were calculated for each room. The air exchange rate values ranged from 0.18 to 0.53 h−1 when mechanical extraction ventilation was off, and from 0.45 to 0.90 h−1 when mechanical extraction ventilation was on, which represents an average increase of 119%. With the current intermittent ventilation strategy, all rooms remain above 1500 ppm for a given percentage of time, and 12 rooms presenting CO2 concentrations above 2000 ppm. Simulations of theoretical CO2 concentrations, for a non-interrupted mechanical ventilation strategy show that no rooms would accumulate CO2 concentrations above 2000 ppm, and only 25% would present CO2 concentrations above 1500 ppm. Pearson correlations between the monitored CO2 and human and spatial factors identified two relevant parameters. Those parameters correspond to ratios between CO2 generation and floor area ([Formula: see text]), and airflow with CO2 generation ([Formula: see text]). The proposed ratios could be used as ways to optimise ventilation costs and indoor air quality.


2014 ◽  
Vol 191 (4S) ◽  
Author(s):  
Hyoungkeun Park ◽  
Sangrak Bae ◽  
Sunghyun Paick ◽  
Hyunwoo Kim ◽  
Jutae Seo ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Prince Junior Asilevi ◽  
Patrick Boakye ◽  
Sampson Oduro-Kwarteng ◽  
Bernard Fei-Baffoe ◽  
Yen Adams Sokama-Neuyam

AbstractNon-thermal plasma (NTP) is a promising technology for the improvement of indoor air quality (IAQ) by removing volatile organic compounds (VOCs) through advanced oxidation process (AOP). In this paper, authors developed a laboratory scale dielectric barrier discharge (DBD) reactor which generates atmospheric NTP to study the removal of low-concentration formaldehyde (HCHO), a typical indoor air VOC in the built environment associated with cancer and leukemia, under different processing conditions. Strong ionization NTP was generated between the DBD electrodes by a pulse power zero-voltage switching flyback transformer (ZVS-FBT), which caused ionization of air molecules leading to active species formation to convert HCHO into carbon dioxide (CO2) and water vapor (H2O). The impact of key electrical and physical processing parameters i.e. discharge power (P), initial concentration (Cin), flow rate (F), and relative humidity (RH) which affect the formaldehyde removal efficiency (ɳ) were studied to determine optimum conditions. Results show that, the correlation coefficient (R2) of removal efficiency dependence on the processing parameters follow the order R2 (F) = 0.99 > R2 (RH) = 0.96, > R2 (Cin) = 0.94 > R2 (P) = 0.93. The removal efficiency reached 99% under the optimum conditions of P = 0.6 W, Cin = 0.1 ppm, F = 0.2 m3/h, and RH = 65% with no secondary pollution. The study provided a theoretical and experimental basis for the application of DBD plasma for air purification in the built environment.